Lake County Zoning Code § 10.16 Maximum height
Lake County Zoning Code · 2026-06 edition · updated 2026-09-23 · Lake County
Cite as: Lake County Zoning Code § 10.16 · Text as of 2026-09-23
(a) Principal structure: Thirty-five (35) feet.
- (b) Accessory structure: Twenty (20) feet. (Ord. No. 1749, 7/7/1988)
10.17 Animal density: Parcels shall be limited to the raising, feeding, maintaining, and breeding of horses at the density of one (1) horse per forty thousand (40,000) square feet of area.
10.18 Parking: The following minimum parking requirements shall apply except as provided in Article 46.
(a) Residential use: Two (2) spaces. (Ord. No. 2128, 1/14/1993; Ord. No. 2305, 10/19/1995)
(b) Other uses: As provided for an Article 46. (Ord. No. 2128, 1/14/1993; Ord. No. 2305, 10/19/1995)
(c) Detached and attached garages, shops and carports, and storage sheds exceeding 199 square feet, shall be subject to the design standards of Section 10.20 (d), (e), (g) & (h). (Ord. No. 2618, 2/27/2003)
10.19 Signs: As provided in Article 45.
10.20 Minimum residential construction standards : All single family dwellings except “Temporary Dwellings” shall meet the following minimum residential construction standards : (Ord. No. 2172, 8/12/1993)
(a) All dwelling units must be at least twelve (12) feet in width or diameter (excluding eaves) and at least three hundred sixty (360) square feet in gross floor area, except “Granny Units” and “Guest Houses” permitted in Article 27. (Ord. No. 3077, 11/20/2018)
(b) Manufactured homes shall be certified under the National Manufactured Home Construction and Safety Standards Act of 1974 and shall not be older than ten (10) calendar years from the date that the building permit application is submitted to the Community Development Department for installation. An exception to this age limit may be granted by the Community Development Director for manufactured homes proposed to be relocated from an existing mobilehome park located within the jurisdictional boundary of the County of Lake, under the following circumstances:
- The parcel upon which the manufactured home is proposed to be installed was purchased by the owner of said manufactured home prior to
10-3
September 15, 2015, and the manufactured home has been owned by the same party for a minimum of two (2) years.
The manufactured home was manufactured on or after July 1, 1976 and can be retrofitted to meet current standards under state and federal laws governing the construction of manufactured homes, and the minimum residential construction standards of Section 10.20 of this Article. (Ord. 3027, 4/08/2015)
(c) All dwelling units shall be attached to permanent continuous concrete or masonry perimeter foundations, or to permanent foundation systems pursuant to Health and Safety Code Section 18551. Where permanent foundation systems are used, except in the “A”, “APZ”, “TPZ”, and “RL” districts, dwelling units shall be provided with continuous six (6) inch wide concrete or masonry perimeter curb walls extending from a minimum of three (3) inches below grade to a minimum of six (6) inches above grade. The underfloor areas of dwelling units requiring curb walls shall be ventilated by openings of not less than one square foot for each one hundred fifty (150) square feet of underfloor area. (Ord. 1936, 6/7/1990; Ord. No. 1974, 12/20/1990)
(d) All units shall be designed so that exterior walls look like wood or masonry or stucco regardless of their actual composition.
(e) The roofing materials shall be designed to look like composition roofing, tile, shakes, shingles, or tar and gravel; or architectural metal roof sheathing with factory applied color coatings.
(f) Unit siding shall extend to the ground level (wood excluded) except that when a solid concrete or masonry perimeter foundation or curb wall is used, then siding need only extend one and one-half (1 ½) inch below the top of the foundation or curb wall. (Ord. No. 1974, 12/20/1990)
(g) The slope of the main roof shall not be less than two (2) inches of vertical rise for twelve (12) inches of horizontal run.
(i) All units shall have a perimeter roof overhang on all sides extending not less than six (6) inches measured from the vertical side of the home, not including rain gutters. (Ord. No. 2128, 1/14/1993; Ord. No. 3077, 11/20/2018)
(j) Where any accessory structure is attached to the main structure, the eave requirement at the point of attachment may be waived by the Planning Director.
(k) The Planning Director may waive the requirements of Subsections (f), (g) and (h) when additions to existing dwellings without pitched roofs or roof overhangs are proposed, or when a proposed new dwelling has an architectural design or style including but not limited to the French Mansard, pole houses, domes or California Mission styles.
10-4
(l) The Planning Director may waive the perimeter requirement of subsection ( c) for pole houses, cantilever construction or similar architectural styles. (Ord 1936, 6/7/1990)
10.21 DEVELOPMENT STANDARDS EXCEPTIONS : FOR EXCEPTIONS TO THE DEVELOPMENT STANDARDS OF THIS ARTICLE, SEE ARTICLE 42. (Ord. No. 1749, 7/7/1988)