Earlier editions: 2026-09
La Quinta Municipal Code Ch. 9.130 Special Purpose Development Standards
La Quinta Municipal Code · 2026-10 edition · updated 2026-10-04 · La Quinta
Cite as: La Quinta Municipal Code Chapter 9.130 · Text as of 2026-10-04
9.130.010 - Table of development standards.¶
Table 9-9 contains standards for development of property within special purpose districts:
Table 9-9 Special Purpose District Development Standards
| District | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Development Standard | Development Standard | PR | GC | OS | FP | HC | EOD | AHO | A/ER | MU |
| Minimum building site | Minimum building site | n/a | n/a | n/a | * | 20,000 sf | *** | 1 acre | 10,000 sf/20,000 sf multifamily | 1 acre |
| Minimum lot frontage | Minimum lot frontage | n/a | n/a | n/a | n/a | 100 ft. | n/a | 100 | 100 | n/a |
| Maximum structure height (ft.) 1 | Maximum structure height (ft.) 1 | 28 | 28 | 28 | * | 28 | *** | 40 | 28 | *** |
| Maximum lot coverage | Maximum lot coverage | n/a | n/a | n/a | n/a | 30% | n/a | 60% | 40% | *** |
| Maximum number of stories | Maximum number of stories | 2 | 2 | 2 | * | 2 | *** | 4 | 2 | *** |
| Minimum setbacks | Minimum setbacks | n/a | n/a | n/a | n/a | Front: 30 Int./Ext. Side: 10/20 Rear: 30 | n/a | Front: 10 Int./Ext. Side: 10/15 Rear: 20 | Front: 30 Garage: 20 Side: 20 Rear: 30 | *** |
| Minimum perimeter building/ landscape setbacks (ft.) 2,4 | From Highway 111 right-of-way | 50/50 | 50/50 | 50/50 | 50/50 | 50/50 | 50/50 | n/a | *** | *** |
| Minimum perimeter building/ landscape setbacks (ft.) 2,4 | From perimeter street ROWs | 30 | 30 | 30 | * | 10′ min, 20′ average | *** | 10′ min, 20′ average | 20 | *** |
| Minimum perimeter building/ landscape setbacks (ft.) 2,4 | From all image corridor 3 rights-of-way (except Hwy 111) and from all major and primary arterials | 30/20 | 30/20 | 30/20 | 30/20 | 30/20 | 30/20 | *** | *** | *** |
| Minimum perimeter building/ landscape setbacks (ft.) 2,4 | From abutting residential property or districts | 30 | 30 | 30 | * | ** | *** | *** | *** | *** |
| Minimum perimeter building/ landscape setbacks (ft.) 2,4 | From abutting commercial and other nonresidential property or districts | 20 | 20 | 20 | * | ** | *** | *** | *** | *** |
| Minimum setback from interior property lines within the same project 4 | Minimum setback from interior property lines within the same project 4 | 0 | 0 | 0 | * | ** | *** | *** | *** | *** |
| Parking and signs | Parking and signs | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 | See Chapters 9.150 and 9.160 |
| Fences and walls | Fences and walls | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 | See Section 9.100.030 |
| Landscaping and screening | Landscaping and screening | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 | See Sections 9.100.040 and 9.100.050 |
Notes:
* As required for needed flood control structures.
** As provided in the HC supplemental regulations, Section 9.140.040.
*** As provided in the underlying base district regulations, subject to the additional requirements of the overlay district in Chapter 9.140.
1 Not including basements. Also, notwithstanding above table, the maximum structure height equals 22 feet for all buildings within 150 feet of any General Plan image corridor and major or primary arterials. Any proposed building height over 22 feet requires minor use permit approval and shall not exceed a maximum building height of the existing zone.
2 Landscape setback shall consist of landscaped area within the building setback. Number given is minimum landscaped setback from the street right-of-way. The remaining building setback may contain parking, driveways and similar facilities.
3 The image corridors as identified in the General Plan.
4 In the AHO, for interior yards, 5 feet minimum plus 1 foot additional setback for every foot of building height above 28 feet, or fraction thereof, up to a maximum setback of 15 feet when said height above 17 feet is located between 5 and 10 feet from said side yard property line. If the building is over 28 feet in height, the setback is 10 feet plus 1 foot for every foot over 28 feet in height or fraction thereof, to a maximum setback of 15 feet. The additional setback may be provided entirely at grade level or may be a combination of at grade and airspace above the 28-foot building height.
(Ord. 602 Exh. A, 2022; Ord. 588 § 2(Exh. A), 2-2-2021; Ord. 550 § 1, 2016; Ord. 512 § 1, 2013; Ord. 445 § 4, 2007; Ord. 284 § 1, 1996)