§ 15.16.010. Warning lights for towers and cranes.

At least one warning light shall be affixed to the top of all towers, cranes and other like projections more than 150 feet above the adjacent ground surfaces. The warning lights shall be flashing incandescent of at least 620 watts. The steady burning intensity shall not be less than 2,000 candelas (in red). The flashing mechanisms shall produce not more than 40 flashes per minute nor less than 12 flashes per minute.

(Prior code § 21-10)