Compton Municipal Code § 15-4 Building Code

Compton Municipal Code · 2026-10 edition · updated 2026-10-04 · Compton

Cite as: Compton Municipal Code § 15-4 · Text as of 2026-10-04

§ 15-4.1. 2019 California Building Code Adopted.

[Added 10-26-2021 by Ord. No. 2339]

The '2019 California Building Code', including Appendices I, J, and O and incorporating the '2018 International Building Code' as published by the International Code Council, hereby is adopted by reference in its entirety as the Building Code of the City of Compton, together with the amendments, additions, deletions and exceptions set forth in this Chapter.

Exceptions & meaning →

§ 15-4.2. 2019 California Building Code - Amendments.

[Added 10-26-2021 by Ord. No. 2339]

The California Building Code is hereby amended as follows:

Section 105.2 Work Exempt from Permit - Amended.

105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following:

a. Building:

  1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11 m2) and maximum height of 12 feet.

  2. Masonry fences less than five feet high, wood or similar less than six feet high.

  3. Oil derricks.

  4. Retaining walls that are not over four feet (1,219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids.

  5. Water tanks supported directly on grade if the capacity does not exceed 5,000 gallons (18,925 L) and the ratio of height to diameter or width does not exceed 2:1.

  6. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below and are not part of an accessible route.

  7. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work.

  8. Temporary motion picture, television and theater stage sets and scenery.

  9. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less than 18 inches (457 mm) deep, do not exceed 5,000 gallons (18,925 L) and are installed entirely above ground.

  10. Shade cloth structures constructed for nursery or agricultural purposes, not including service systems.

  11. Swings and other playground equipment accessory to detached one- and two-family dwellings, not exceeding eight feet high.

  12. Window awnings supported by an exterior wall that do not project more than 54 inches (1,372 mm) from the exterior wall and do not require additional support of Groups R-3 and U occupancies.

  13. Nonfixed and movable fixtures, cases, racks, counters and partitions not over five feet nine inches (1,753 mm) in height.

b. Electrical:

  1. Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles.

  2. Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions, but do apply to equipment and wiring for a power supply and the installations of towers and antennas.

  3. Temporary testing systems: A permit shall not be required for the installation of any temporary system required for the testing or servicing of electrical equipment or apparatus.

c. Gas:

  1. Portable heating appliance.

  2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe.

d. Mechanical:

  1. Portable heating appliance.

  2. Portable ventilation equipment.

  3. Portable cooling unit.

  4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code.

  5. Replacement of any part that does not alter its approval or make it unsafe.

  6. Portable evaporative cooler.

  7. Self-contained refrigeration system containing 10 pounds (5 kg) or less of refrigerant and actuated by motors of 1 horsepower (746 W) or less.

e. Plumbing:

  1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with the new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code.

  2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures.

Section 105.5 Expiration - Amended.
105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 365 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The building official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated.
Exceptions & meaning →