Chapter 14 — Remedial Residential Regulations, Unreinforced Masonry Walls, and Flood Plain Management

Compton Municipal Code § 14-8 Earthquake Hazard Reduction in Existing Buildings

Compton Municipal Code · 2026-10 edition · updated 2026-10-04 · Compton

Cite as: Compton Municipal Code § 14-8 · Text as of 2026-10-04

[1]

Tables A-J referred to herein are included as an attachment to this chapter.

§ 14-8.1. Scope.

[Added by Ord. #1829, §§ 1, 2]

The provisions of this Chapter shall apply to all buildings constructed or under construction prior to March 10, 1933, or for which a building permit was issued prior to March 10, 1933, which on the effective date of this section have unreinforced masonry bearing walls as defined herein.

EXCEPTION: This Chapter shall not apply to detached one or two family dwellings and detached apartment houses containing fewer than five dwelling units and used solely for residential purposes.

Exceptions & meaning →

§ 14-8.2. Definitions.

[Added by Ord. #1829, §§ 1, 2; amended 10-26-2021 by Ord. No. 2339]

For purposes of this Chapter, the applicable definitions in the California Building Code and the following shall apply:

ESSENTIAL BUILDING

Shall mean any building housing a hospital or other medical facility having surgery or emergency treatment areas, fire or police stations, municipal government disaster operation and communication centers.

HIGH-RISK BUILDING

Shall mean any building not classified as essential having an occupant load as determined by the California Building Code of 100 occupants or more.

EXCEPTION: A high-risk building shall not include the following:

a.

Any building having exterior walls braced with masonry cross walls or wood frame cross walls spaced less than 40 feet apart in each story. Cross walls shall be full story height with a minimum length of 1 1/2 times the story height.

b.

Any building used for its intended purpose as determined by the department for less than 20 hours per week.

HISTORICAL BUILDING

Shall mean any building designated as a historical building by an appropriate Federal, State or City jurisdiction.

LOW-RISK BUILDING

Shall mean any building not classified an essential building having an occupant load as determined by the California Building Code of less than 20 occupants.

MEDIUM-RISK BUILDING

Shall mean any building not classified as a high-risk building or an essential building having an occupant load as determined by the California Building Code of 20 occupants or more.

UNREINFORCED MASONRY BEARING WALL

Shall mean a masonry wall having all of the following characteristics:

a.

Provides the vertical support for a floor or roof.

b.

The total superimposed loan is over 100 pounds per linear foot.

c.

The area of reinforcing steel is less than 50% of that required by the California Building Code.

Exceptions & meaning →

§ 14-8.3. Rating Classification.

[Added by Ord. #1829, §§ 1, 2; amended 10-26-2021 by Ord. No. 2339]

The rating classifications as exhibited in Table No. 14-A are hereby established and each building within the scope of this Chapter shall be placed in one such rating classification by the City. The total occupant load of the entire building as determined by the California Building Code shall be used to determine the rating classifications.

EXCEPTION: For the purpose of this Chapter, portions of buildings constructed to act independently when resisting seismic forces may be placed in separate rating classifications.

Exceptions & meaning →

§ 14-8.4. General Requirements.

[Added by Ord. #1829, §§ 1, 2]

The owner of each building within the scope of this Chapter shall cause a structural analysis to be made of the building by a civil or structural engineer or architect licensed by the State of California, and if the building does not meet the minimum earthquake standards specified in this Chapter, the owner shall cause it to be structurally altered to conform to such standards or cause the building to be demolished.

The owner of a building within the scope of this Chapter shall comply with the requirements set forth above by submitting to the City for review within the stated time limits:

a. Within 270 days after the service of the order, a structural analysis. Such analysis, which is subject to approval by the City, shall demonstrate that the building meets the minimum requirements of this Chapter; or

b. Within 270 days after the service of the order, a structural analysis and plans for the proposed structural alterations of the building necessary to comply to the minimum requirements of this Chapter; or

c. Within 120 days after service of the order, plans for the installation of wall anchors in accordance with the requirements specified in subsection 14-8.8; or

d. Within 270 days after the service of the order, plans for the demolition of the building.

After plans are submitted and approved by the City, the owner shall obtain a building permit, commence and complete the required construction or demolition within the time limits set forth in Table No. 14-B. These time limits shall begin to run from the date the order is served in accordance with subsection 14-8.6 .
Owners electing to comply with paragraph c of this subsection, are also required to comply with paragraphs b or d of this subsection, provided, however, that the 270-day period provided for in such paragraphs b and d and the time limits for obtaining a building permit, commencing construction and completing construction for complete structural alterations or building demolition set forth in Table No. 14-B shall be extended in accordance with Table No. 14-C. Each such extended time limit, except the time limit for commencing construction, shall begin to run from the date the order is served in accordance with subsection 14-8.6 . The time limit for commencing construction shall run from the date the building permit is issued.
Exceptions & meaning →

§ 14-8.5. Administration.

[Added by Ord. #1829, §§ 1, 2; amended by Ord. #2224, § 19; amended 10-26-2021 by Ord. No. 2339]

a. Service of Order. The City shall issue an order, as provided in paragraph b below, to the owner of each building within the scope of this Chapter in accordance with the minimum time periods for service of such orders set forth in Table Nos. 14-B and C. The City shall, upon receipt of a written request from the owner, order a building to comply with this Chapter prior to the normal service date for such building set forth in this section.

b. Contents of Order. The order shall be in writing and shall be served either personally or by certified or registered mail upon the owner as shown on the last equalized assessment, and upon the order shall specify that the building has been determined by the City to be within the scope of this Chapter and, therefore, is required to meet the minimum seismic standards of this Chapter. The order shall specify the rating classification of the building and shall be accompanied by a copy of subsection 14-8.5, which sets forth the owner's alternatives and time limits for compliance.

c. Appeal from Order. The owner or person in charge or control of the building may appeal, as provided for in this Chapter. Such appeal shall be filed within 60 days from the service date of the order described in this subsection 14-8.6. Any such appeal shall be decided by the Board or Hearing Officer no later than 60 days after the date that the appeal is filed. Such appeal shall be made in writing upon appropriate forms provided therefor by the City, and the grounds thereof shall be stated clearly and concisely. Each appeal shall be accompanied by a filing fee as set forth in paragraph f of this subsection.

Appeals or request for slight modifications from any other determination, orders or action by the City pursuant to this Chapter shall be made in accordance with the procedures established in Section 106 of the California Building Code .

d. Recordation. At the time that the City serves the aforementioned order, the City shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope of Earthquake Hazard Reduction in Existing Buildings of the Compton Municipal Code. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to structurally alter or demolish it where compliance is not exhibited.

If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the City shall file with the Office of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of Earthquake Hazard Reduction in Existing Buildings of the Compton Municipal Code.

e. Enforcement. If the owner or other person in charge or control of the subject building fails to comply with any order issued by the City pursuant to this Chapter within any of the time limits set forth in subsection 14-8.5, the City shall order that the entire building be vacated and that the building remain vacated until such order has been complied with. If compliance with such order has not been accomplished within 90 days after the date the building has been ordered vacated or such additional time as may have been granted by the Board or Hearing Officer, the Building and Safety Director may order its demolition in accordance with the provision of this Code.

f. Appellate Fee; Building and Safety Director.

  1. The fee for an appeal of the Building and Safety Director's action shall be $75.[1]

[1]

Editor's Note: Fees increased/decreased pursuant to subsection 14-8.2f may be set by Council resolution.

  1. The fee for an appeal to the City Council of any action of the Board or Hearing Officer shall be $250.
Exceptions & meaning →

§ 14-8.6. Historical Buildings.

[Added by Ord. #1829, §§ 1, 2]

a. General. The standards and procedures established by this Chapter shall apply in all aspects to a historical building except that as a means to preserve original architectural elements and facilitate restoration, a historical building may, in addition, comply with the special provisions set forth in this section.

b. Unburned Clay Masonry or Adobe. Existing or re-erected walls of adobe construction shall conform to the following:

  1. Unreinforced adobe masonry walls shall not exceed a height or height-to-thickness ratio of five for exterior bearing walls and must be provided with a reinforced bond beam at the top, interconnecting all walls. Minimum beam depth shall be six inches and a minimum width of eight inches less than the wall width.

Minimum wall thickness shall be 18 inches for exterior bearing walls and 10 inches for adobe partitions. No adobe structure shall exceed one story in height unless the historic evidence indicates a two-story height. In such cases, the height-to-thickness ratio shall be the same as above for the first floor based on the total two-story height, and the second floor wall thickness shall not exceed the ratio five by more than 20%. Bond beams shall be provided at the roof and second floor levels.

  1. Foundation footing shall be reinforced concrete under newly reconstructed walls and shall be 50% wider than the wall above, soil conditions permitting, except that the foundation wall may be four inches less in width than the wall above if a rock, burned brick, or stabilized adobe facing is necessary to provide authenticity.

  2. New or existing unstabilized brick and adobe brick masonry shall have an average compressive strength of 225 pounds per square inch when tested in accordance with ASTM designation C 67. One sample out of five may have a compressive strength of not less than 188 pounds per square inch. Unstabilized brick may be used where existing bricks are unstabilized and where the building is not susceptible to flooding conditions or direct exposure. Adobe may be allowed a maximum value of three pounds per square inch for shear with no increase for lateral forces.

  3. Mortar may be of the same soil composition and stabilization as the brick in lieu of cement mortar.

  4. Nominal tension stresses due to seismic forces normal to the wall may be neglected if the wall meets thickness requirements and shear values allowed by this subsection.

c. Archaic Materials. Allowable stresses for archaic materials net specified in this Code shall be based on substantiating research data or engineering judgment, subject to the Department's satisfaction.

d. Alternative Materials and SHBC Advisory Review. Alternative materials, design or methods of construction will be considered as set forth in subsection 14-8.9. In addition, when a request for an alternative proposed design, material or method of construction is being considered, the City may file written request for opinion to the State Historical Building Code Advisory Board for its consideration, advice or findings in accordance with the SHBC.

Exceptions & meaning →

§ 14-8.7. Analysis and Design.

[Added by Ord. #1829, §§ 1, 2; amended 10-26-2021 by Ord. No. 2339]

a. General. Every structure within the scope of this Chapter shall be analyzed and constructed to resist minimum total lateral seismic forces assumed to act nonconcurrently in the direction of each of the main axis of the structure in accordance with the equation v = IKCSW:

The value of IKCS need not exceed the values set forth in Table No. 14-D based on the applicable rating classification of the building.

b. Lateral Forces on Elements of Structures. Parts or portions of structures shall be analyzed and designed for lateral loads in accordance with the California Building Code but not less than the value from the equation: Fp = ICp SEp.

For the provisions of this subsection, the product of IS need not exceed the values as set forth in Table No. 14-E.

EXCEPTION: Unreinforced masonry walls in buildings and having a Rating Classification of 1 may be analyzed in accordance with subsection 14-8.9.

The value of Cp need not exceed the values set forth in Table No. 14-F.

c. Anchorage and Interconnection. Anchorage and interconnection of all parts, portions and elements of the structure shall be analyzed and designed for lateral forces in accordance with Table No. 14-F of this Chapter and the equation Fp = ICpSW as modified by Table No. 14-E. Minimum anchorage of masonry walls to each floor or roof shall resist a minimum force of 200 pounds per linear foot acting normal to the wall at the level of the floor or roof.

d. Level of Required Repair. Alteration and repairs required to meet the provisions of this Chapter shall comply with all other applicable requirements of this Code unless specifically provided for in this Chapter.

e. Required Analysis.

  1. General. Except as modified herein, the analysis and design relating to the structural alteration of existing structures within the scope of this Chapter shall be in accordance with the analysis specified in the California Building Code, or as it may be amended from time to time.

  2. Continuous Stress Path. A complete, continuous stress path from every part or portion of the structure to the ground shall be provided for the required horizontal forces.

  3. Positive Connections. All parts, portions or elements of the structure shall be interconnected by positive means.

f. Analysis Procedure.

  1. General. Stresses in materials and existing construction utilized to transfer seismic forces from the ground to parts or portions of the structure shall conform to those permitted by the California Building Code and those materials and types of construction specified in subsection 14-8.9.

EXCEPTION: The Building Official has the authority to accept alternate methods of retrofit in accordance with the California Building Code.

  1. Connection. Materials and connectors used for interconnection of parts and portions of the structure shall conform to the California Building Code. Nails may be used as part of an approved connector.

  2. Unreinforced Masonry Walls. Except as modified herein, unreinforced masonry walls shall be analyzed as specified in the California Building Code and to withstand all vertical loads as specified in the California Building Code in addition to the seismic forces required by this Chapter. The 50% increase in the seismic force factor for shear walls as specified in the California Building Code may be omitted in the computation of seismic loads to existing shear walls.

No allowable tension stress will be permitted in unreinforced masonry walls. Walls not capable of resisting the required design forces specified in this Chapter shall be strengthened or shall be removed and replaced.

EXCEPTION:

(a) Unreinforced masonry walls in buildings not classified as a Rating Classification I pursuant to Table No. 14-A may be analyzed in accordance with subsection 14-8.9.

(b) Unreinforced masonry walls which carry no design loads other than their own weight may be considered as veneer if they are adequately anchored to new supporting elements.

g. Combination of Vertical and Seismic Forces.

  1. New Materials. All new materials introduced into the structure to meet the requirements of this section which are subjected to combined vertical and horizontal forces shall comply with the California Building Code.

  2. Existing Materials. When stresses in existing lateral force-resisting elements are due to a combination of dead loads plus seismic loads, the allowable working stress specified in the California Building Code may be increased 100%. However, no increase will be permitted in the stresses allowed in subsection 14-8.9 and the stresses in members due only to seismic and dead loads shall not exceed the values permitted by the California Building Code.

  3. Allowable Reduction of Bending Stress by Vertical Load. In calculating tensile fiber stress due to seismic forces required by this Chapter, the maximum tensile fiber stress may be reduced by the full direct stress due to vertical dead loads.

Exceptions & meaning →

§ 14-8.8. Materials of Construction.

[Ord. #1829, §§ 1, 2; amended 10-26-2021 by Ord. No. 2339]

a. General. All materials permitted by the California Building Code , including their appropriate allowable stresses and those existing configurations of materials specified herein, may be utilized to meet the requirements of this Chapter.

b. Existing Materials.

  1. Unreinforced Masonry Walls. Unreinforced masonry walls analyzed in accordance with this section may provide vertical support for roof and floor construction and resistance to lateral loads. The bonding of such walls shall be as specified in the California Building Code .

Tension stresses due to seismic forces normal to the wall may be neglected if the wall does not exceed the height for length-to-thickness ratio and the in-plane shear stresses due to seismic loads as set forth in Table No. 14-G.

If the wall height-thickness ratio exceeds the specified limits, the wall may be supported by vertical bracing members designed in accordance with the California Building Code . The deflection of such bracing members at design loads shall not exceed 1/10 of the wall thickness.

EXCEPTION: The wall may be supported by flexible vertical bracing members designed in accordance with subsection 14-8.8b, if the deflection of design load is not less than 1/4 nor more than 1/3 of the wall thickness.

All vertical bracing members shall be attached to floor and roof construction for their design loads independently of required wall anchors. Horizontal spacing of vertical bracing members shall not exceed 1/2 the unsupported height of the wall nor 10 feet.

The wall height may be measured vertically to bracing elements other than a floor or roof. Spacing of the bracing elements and wall anchors shall not exceed six feet. Bracing elements shall be detailed to minimize the horizontal displacement of the wall by components of vertical displacement of the floor or roof.

  1. Existing Roof, Floors, Walls, Footings and Wood Framing. Existing materials, including wood shear walls utilized in the described configuration, may be used as part of the lateral load resisting system, provided that the stresses in these materials do not exceed the values shown in Table No. 14-H.

c. Strengthening of Existing Materials. New materials including wood shear walls, may be utilized to strengthen portions of the existing seismic resisting system in the described configurations, provided that the stresses do not exceed the values shown in Table No. 14-I (attached).

d. Alternate Materials. Alternate materials, designs and methods of construction may be approved by the City in accordance with the provision of the California Building Code .

e. Minimum Acceptable Quality of Existing Unreinforced Masonry Walls.

  1. General Provisions. All unreinforced masonry walls utilized to carry vertical loads and seismic forces parallel and perpendicular to the wall plane shall be tested as specified in this subsection. All masonry quality shall equal or exceed the minimum standards established herein or shall be removed and replaced by new materials. Alternate methods of testing may be approved by the City. The quality of mortar in all masonry walls shall be determined by performing in-place shear tests or by testing eight inch diameter cores. Alternative methods of testing may be approved by the City. Nothing shall prevent pointing with mortar of all the masonry wall joints before the tests are first made. Prior to any pointing, the mortar joints must be raked and cleaned to remove loose and deteriorated mortar. Mortar for pointing shall be Type S or N except masonry cement shall not be used. All preparation and mortar pointing shall be done under the continuous inspection of a registered deputy building inspector.

At the conclusion of the inspection, the inspector shall submit a written report to the licensed engineer or architect responsible for the seismic analysis of the building setting forth the result of the work inspected. Such report shall be submitted to the City for approval as part of the structural analysis. All testing shall be performed in accordance with the requirements specified in this subsection by testing agency approved by the City. An accurate record of all such tests and their location in the building shall be recorded and these results shall be submitted to the City for approval as part of the structural analysis.

  1. Number and Location of Tests. The minimum number of tests shall be two per wall or line of wall elements resisting a common force, or one per 1,500 square feet of wall surface, with a minimum of eight tests in any case. The exact test or core location shall be determined at the building site by the licensed engineer or architect responsible for the seismic analysis of the subject building.

  2. In-Place Shear Tests. The bed joints of the outer withe of the masonry shall be tested in shear by laterally displacing a single brick relative to the adjacent bricks in that withe. The opposite head joint of the brick to be tested shall be removed and cleaned prior to testing. The minimum quality mortar in 80% of the shear tests shall not be less than the total of 30 psi plus the axial stress in the wall at the point of the test. The shear stress shall be based on the gross area of both bed joints and shall be that at which movement of the brick is first observed.

  3. Core Tests. A minimum number of mortar test specimens equal to the number of required cores shall be prepared from the cores and leveled as specified herein. The mortar joint of the outer withe of the masonry core shall be tested in shear by placing the circular core section in a compression testing machine with the mortar bed joint rotated 15° from the axis of the applied load. The mortar joint tested in shear shall have an average ultimate stress of 20 psi braced on the gross area. The average shall be obtained from the total number of cores made. If test specimens cannot be made from cores taken then the shear value shall be reported as zero.

f. Testing of Shear Bolts. One-fourth of all new shear bolts and dowels embedded in unreinforced masonry walls shall be tested by a registered deputy building inspector using a torque calibrate wrench to the following minimum torques:

1/2-inch diameter bolts or dowels - Forty-foot lbs.

5/8-inch diameter bolts or dowels - Fifty-foot lbs.

3/4-inch diameter bolts or dowels - Sixty-foot lbs.

No bolts exceeding 3/4 inch shall be used. All nuts shall be installed over malleable iron or plate washers when bearing on wood and heavy cut washers when bearing on steel.

g. Determination of Allowable Stresses for Design Methods Based on Test Results.

  1. Design Shear Values. Design seismic in-plane shear stresses shall be substantiated by tests performed as specified in subsection 14-8.9e3 and 4.

Design stresses shall be related to test results obtaining in accordance with Table No. 14-J (attached). Intermediate values between three and 10 psi may be interpolated.

  1. Design compression and tension values, compression stresses for unreinforced masonry having a minimum design shear value of three psi shall not exceed 100 psi. Design tension values for unreinforced masonry shall not be permitted.

h. Rod Anchors. 5% of the existing rod anchors utilized as all or part of the required wall anchors shall be tested in pullout by an approved testing laboratory. The number tested shall be four per floor, with two tests at walls with joists framing into the wall and two tests at walls with joists parallel to the wall. The test apparatus shall be supported on the masonry wall at a minimum distance of the wall thickness from the anchor tested. The rod anchor shall be given a preload of 300 pounds prior to establishing a datum for recording elongation. The tension test load reported shall be recorded at 1/2 inch relative movement of the anchor and the adjacent masonry surface. Results of all tests shall be reported. The report shall include the test results as related to the wall thickness and joist orientation. The allowable resistance value of the existing anchors shall be 40% of the average of those tested anchors having the same wall thickness and joist orientation.

i. Qualification Tests for Devices Used for Wall Anchorage. Qualifications tests for devices used for wall anchorage shall be tested with the entire tension load carried on the enlarged head at the exterior face of the wall. Bond on the part of the device between the enlarged head and the interior wall face shall be eliminated for the qualification tests. The resistance value assigned the device shall be 20% of the average of the ultimate loads.

Exceptions & meaning →

§ 14-8.9. Information Required on Plans.

[Added by Ord. #1829, §§ 1, 2; amended 10-26-2021 by Ord. No. 2339]

a. General. In addition to the seismic analysis required elsewhere in this Chapter, the licensed engineer or architect responsible for the seismic analysis of the building shall determine and record the information required by the section on the approved plans.

b. Construction Details. The following requirements with appropriate construction details shall be made part of the approved plans:

  1. All unreinforced masonry walls shall be anchored at the roof level by tension bolts through the wall as specified in Table No. I or by approved equivalent at a maximum anchor spacing of six feet. Anchors installed in accordance with the California Building Code shall be accepted as conforming to this requirement.

All unreinforced masonry walls shall be anchored at all floors with tension bolts through the wall or by existing rod anchors at a maximum anchor spacing of six feet. All existing rod anchors shall be secured to the joists to develop the required forces. The City may require testing to verify the adequacy of the embedded ends of the existing rod anchors. Tests when required shall conform to subsection 14-8.9h.

When access to the exterior face of the masonry wall is prevented by proximity of an existing building, wall anchors conforming to items 5 and 6 in Table No. 14-I may be used.

Alternative devices to be used in lieu of tension bolts for masonry wall anchorage shall be tested as specified in subsection 14-8.9i.

  1. Diaphragm cord stresses of horizontal diaphragms shall be developed in existing materials or by addition of new materials.

  2. Where trusses and beams other than rafters or joists are supported on masonry, ledges or columns shall be installed to support vertical loads of the roof or floor members.

  3. Parapets and exterior wall appendages not capable of resisting the forces specified in this Chapter shall be removed, stabilized or braced to ensure that the parapets and appendages remain in their original position.

  4. All deteriorated mortar joints in unreinforced masonry walls shall be pointed with Type S or N mortar. Prior to any pointing, the wall surface must be raked and cleaned to remove loose and deteriorated mortar. All preparation and pointing shall be done under the continuous inspection of a registered deputy building inspector certified to inspect masonry or concrete. At the conclusion of the project, the inspector shall submit a written report to the City setting forth the portion of work inspected.

  5. Repair details of any cracked or damaged unreinforced masonry wall required to resist forces specified in this Chapter.

c. Existing Construction. The following existing construction information shall be made part of the approved plans:

  1. The type and dimensions of existing walls and the size and spacing of floor and roof members.

  2. The extent and type of existing wall anchorage to floors and roof.

  3. The extent and type of parapet corrections which were performed in accordance with the California Building Code.

  4. Accurately dimensioned floor plans and masonry wall elevations showing dimensioned openings, piers, wall thickness and heights.

  5. The location of cracks or damaged portions of unreinforced masonry walls requiring repairs.

  6. The type of interior wall surfaces and if reinstalling or anchoring of ceiling plaster is necessary.

  7. The general condition of the mortar joints and if the joints need pointing.