Title 15 — BUILDINGS AND CONSTRUCTION›15.09 — 2019 CALIFORNIA FIRE CODE WITH AMENDMENTS

§ 7.7

Clayton Municipal Code · 2026-09 edition · updated 2026-10-02 · Clayton

7.7.1 Where CPVC pipe is installed above the normal insulation in an unconditioned…

attic space, or a garage without conditioned living space above, CPVC pipe shall be adequately insulted to a minimum R-19 value, or equivalent, or pipe shall be limited to Type K or L copper, or ferrous piping.

Section 8.3.5.1.2 is amended to read: