Chapter 9 — ROOF ASSEMBLIES

Section R905 — REQUIREMENTS FOR ROOF COVERINGS

2025 California Residential Code (Title 24, Part 2.5) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

R905.1 Roof covering application.

R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer’s installation instructions. Unless otherwise specified in this section, roof coverings shall be installed to resist the component and cladding loads specified in Table R301.2.1(1), adjusted for height and exposure in accordance with Table R301.2.1(2). R905.1.1 Underlayment. Underlayment in accordance with this section is required for asphalt shingles, clay and concrete tile, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type…

R905.2 Asphalt shingles.

R905.2 Asphalt shingles. The installation of asphalt shingles shall comply with the provisions of this section. R905.2.1 Sheathing requirements. Asphalt shingles shall be fastened to wood structural panels or solid lumber sheathing. R905.2.2 Slope. Asphalt shingles shall be used only on roof slopes of 2 units vertical in 12 units horizontal (17-percent slope) or greater. For roof slopes from 2 units vertical in 12 units horizontal (17-percent slope) up to 4 units vertical in 12 units horizontal (33-percent slope), double underlayment application is required in accordance with Section…

R905.3 Clay and concrete tile.

R905.3 Clay and concrete tile. The installation of clay and concrete tile shall comply with the provisions of this section. R905.3.1 Sheathing requirements. Concrete and clay tile shall be installed over wood structural panels or solid lumber sheathing. Exception: Spaced lumber sheathing in accordance with Section R803.1 shall be permitted in Seismic Design Categories A, B and C. R905.3.2 Slope. Clay and concrete roof tile shall be installed on roof slopes of 2 [1] / 2 units vertical in 12 units horizontal (25-percent slope) or greater. For roof slopes from 2 [1] / 2 units vertical in 12…

R905.4 Metal roof shingles.

R905.4 Metal roof shingles. The installation of metal roof shingles shall comply with the provisions of this section. R905.4.1 Sheathing requirements. Metal roof shingles shall be fastened to wood structural panels, solid lumber sheathing or closely fitted lumber sheathing, except where the roof covering is specifically designed to be applied to spaced lumber sheathing. R905.4.2 Slope. Metal roof shingles shall not be installed on roof slopes below 3 units vertical in 12 units horizontal (25-percent slope). R905.4.3 Underlayment. Underlayment shall comply with Section R905.1.1. R905.4.3.1 Ice…

R905.5 Mineral-surfaced roll roofing.

R905.5 Mineral-surfaced roll roofing. The installation of mineral-surfaced roll roofing shall comply with this section. R905.5.1 Sheathing requirements. Mineral-surfaced roll roofing shall be fastened to wood structural panels or solid lumber sheathing. R905.5.2 Slope. Mineral-surfaced roll roofing shall not be applied on roof slopes below 1 unit vertical in 12 units horizontal (8percent slope). R905.5.3 Underlayment. Underlayment shall comply with Section R905.1.1. R905.5.3.1 Ice barrier. Where required, ice barriers shall comply with Section R905.1.2. R905.5.4 Material standards.…

R905.6 Slate shingles.

R905.6 Slate shingles. The installation of slate shingles shall comply with the provisions of this section. R905.6.1 Sheathing requirements. Slate shingles shall be fastened to wood structural panels or solid lumber sheathing. R905.6.2 Slope. Slate shingles shall be used only on slopes of 4 units vertical in 12 units horizontal (33-percent slope) or greater. R905.6.3 Underlayment. Underlayment shall comply with Section R905.1.1. R905.6.3.1 Ice barrier. Where required, ice barriers shall comply with Section R905.1.2. R905.6.4 Material standards. Slate shingles shall comply with ASTM C406.…

R905.7 Wood shingles.

R905.7 Wood shingles. The installation of wood shingles shall comply with the provisions of this section. R905.7.1 Sheathing requirements. Wood shingles shall be fastened to wood structural panels, solid lumber sheathing or spaced lumber sheathing. Where spaced lumber sheathing is used, sheathing boards shall be not less than 1-inch by 4-inch (25 mm by 102 mm) nominal dimensions and shall be spaced on centers equal to the weather exposure to coincide with the placement of fasteners. Where 1-inch by 4-inch (25 mm by 102 mm) spaced sheathing is installed at 10 inches (254 mm) or greater,…

R905.8 Wood shakes.

R905.8 Wood shakes. The installation of wood shakes shall comply with the provisions of this section. R905.8.1 Sheathing requirements. Wood shakes shall be fastened to wood structural panels, solid lumber sheathing or spaced lumber sheathing. Where spaced lumber sheathing is used, sheathing boards shall be not less than 1-inch by 4-inch (25 mm by 102 mm) nominal dimensions and shall be spaced on centers equal to the weather exposure to coincide with the placement of fasteners. Where 1-inch by 4-inch (25 mm by 102 mm) spaced lumber sheathing is installed at 10 inches (254 mm) on center,…

R905.9 Built-up roofs.

R905.9 Built-up roofs. The installation of built-up roofs shall comply with the provisions of this section and the manufacturer’s approved installation instructions. R905.9.1 Slope. Built-up roofs shall have a design slope of not less than [1] / 4 unit vertical in 12 units horizontal (2-percent slope) for drainage, except for coal-tar built-up roofs, which shall have a design slope of a minimum [1] / 8 unit vertical in 12 units horizontal (1percent slope). R905.9.2 Material standards. Built-up roof covering materials shall comply with the standards in Table R905.9.2 or UL 55A. TABLE…

R905.10 Metal roof panels.

R905.10 Metal roof panels. The installation of metal roof panels shall comply with the provisions of this section. R905.10.1 Sheathing requirements. Metal roof panel roof coverings shall be fastened to wood structural panels, solid lumber sheathing or spaced lumber sheathing, except where the roof covering is specifically designed to be applied to spaced supports. R905.10.2 Slope. Minimum slopes for metal roof panels shall comply with the following: 1. The minimum slope for lapped, nonsoldered-seam metal roofs without applied lap sealant shall be 3 units vertical in 12 units horizontal…

R905.11 Modified bitumen roofing.

R905.11 Modified bitumen roofing. The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer’s approved installation instructions. R905.11.1 Slope. Modified bitumen roofing shall have a design slope of not less than one-fourth unit vertical in 12 units horizontal (2-percent slope) for drainage. R905.11.2 Material standards. Modified bitumen roofing shall comply with the standards in Table R905.11.2. 9-16 2025 CALIFORNIA RESIDENTIAL CODE on Jul 18, 2025 11:14 AM (CDT) THEREUNDER. ROOF ASSEMBLIES TABLE R905.11.2—MODIFIED BITUMEN ROOFING…

R905.12 Single-ply roofing.

R905.12 Single-ply roofing. The installation of single-ply membrane roof coverings shall comply with the provisions of this section. TABLE R905.12—SINGLE-PLY ROOFING MATERIAL STANDARDSCol2 ------ MATERIALSTANDARD Chlorosulfanated polyethylene (CSPE) or polyisobutylene (PIB)ASTM D5019 Ethylene propylene diene monomer (EPDM)ASTM D4637 Ketone Ethylene Ester (KEE)ASTM D6754 Polyvinyl chloride (PVC) or (PVC/KEE)ASTM D4434 Thermosplastic polyolefin (TPO)ASTM D6878 R905.12.1 Slope. Single-ply membrane roof coverings shall have a design slope of not less than [1] / 4 unit vertical in 12 units…

R905.13 Sprayed polyurethane foam roofing.

R905.13 Sprayed polyurethane foam roofing. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. R905.13.1 Slope. Sprayed polyurethane foam roofs shall have a design slope of not less than [1] / 4 unit vertical in 12 units horizontal (2-percent slope) for drainage. R905.13.2 Material standards. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. R905.13.3 Application. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer’s instructions. A…

R905.14 Liquid-applied roofing.

R905.14 Liquid-applied roofing. The installation of liquid-applied roofing shall comply with the provisions of this section. R905.14.1 Slope. Liquid-applied roofing shall have a design slope of not less than [1] / 4 unit vertical in 12 units horizontal (2-percent slope). R905.14.2 Material standards. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. R905.14.3 Application. Liquid-applied roofing shall be installed in accordance with this chapter and the manufacturer’s installation instructions. R905.14.4 Wind resistance of liquid-applied roofing.…

R905.15 BIPV shingles.

R905.15 BIPV shingles. The installation of BIPV shingles shall comply with the provisions of this section, Section R329 and the Cali- fornia Electrical Code . R905.15.1 Sheathing requirements. BIPV shingles shall be fastened to wood structural panels, solid lumber sheathing or closely fitted lumber sheathing, except where the roof covering is specifically designed to be applied over spaced lumber sheathing. R905.15.2 Slope. BIPV shingles shall be used only on roof slopes of 2 units vertical in 12 units horizontal (2:12) or greater. R905.15.3 Underlayment. Underlayment shall comply with…

R905.16 Building-integrated photovoltaic (BIPV) roof panels applied directly to the roof deck.

R905.16 Building-integrated photovoltaic (BIPV) roof panels applied directly to the roof deck. The installation of BIPV roof panels shall comply with the provisions of this section, Section R329 and the California Electrical Code . R905.16.1 Sheathing requirements. BIPV roof panels shall be fastened to wood structural panels, solid lumber sheathing or closely-fitted lumber sheathing, except where the roof covering is specifically designed to be applied over spaced lumber sheathing. R905.16.2 Slope. BIPV roof panels shall be used only on roof slopes of 2 units vertical in 12 units horizontal…