Section 12 — 3-6—SECURE ATTACHMENT TEST

2025 California Referenced Standards Code (Title 24, Part 12) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

12-3-6.1 Two samples of the system shall be subjected to the following test sequence. 12-3-6.2 The system, when in the closed position, shall resist 50-pound (22 N) force without opening, loosening in the test fixture or damaging the releasing assembly. The force shall be applied on the exterior side of the test fixture in a location that is most likely to move or damage the system. The force shall be gradually applied perpendicular to the opening and held for a period of 1 minute. A 3 / 8 -inch (10 mm) diameter rope looped through the security bars, or similar arrangement, shall be used to…