Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
5.407 Water Resistance and Moisture Management — 2025 California Green Building Standards Code
California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-09-25 · California
Cite as: 2025 California Green Building Standards Code (Title 24, Part 11) § 5.407 · Effective January 1, 2026 · Official source: Building Standards Commission
5.407.1 Weather protection. Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2 (Weather Protection), manufacturer’s installation instructions or local ordinance, whichever is more stringent.
5.407.2 Moisture control. Employ moisture control measures by the following methods.
5.407.2.1 Sprinklers. Design and maintain landscape irrigation systems to prevent spray on structures.
5.407.2.2 Entries and openings. Design exterior entries and/or openings subject to foot traffic or wind-driven rain to prevent water intrusion into buildings as follows:
5.407.2.2.1 Exterior door protection. Primary exterior entries shall be covered to prevent water intrusion by using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to such openings plus at least one of the following:
An installed awning at least 4 feet in depth.
The door is protected by a roof overhang at least 4 feet in depth.
The door is recessed at least 4 feet.
Other methods which provide equivalent protection.
5.407.2.2.2 Flashing. Install flashings integrated with a drainage plane.
NONRESIDENTIAL MANDATORY MEASURES