Section A5.404 — EFFICIENT FRAMING TECHNIQUES
California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-09-12 · California
A5.404.1 Wood framing. Employ advanced wood framing techniques or OVE, as recommended by the US Department of Energy’s Office of Building Technology, State and Community Programs and as permitted by the enforcing agency.
A5.404.1.1 Structural or fire-resistance integrity. The OVE selected shall not conflict with structural framing methods or firerated assemblies required by the California Building Code.
A5.404.1.2 Framing specifications. Advanced framing techniques include the following:
- Building design using 2-foot modules;
- Spacing wall studs up to 24 inches on center;
- Spacing floor and roof framing members up to 24 inches on center;
- Using 2-stud corner framing and drywall clips or scrap lumber for drywall backing;
- Eliminating solid headers in non-load-bearing walls;
- Using in-line framing, aligning floor, wall and roof framing members vertically for direct transfer of loads; and
- Using single lumber headers and top plates where appropriate.
Note: Additional information can be obtained from the US DOE Energy Efficiency and Renewable Energy (EERE) website.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Green Building Standards Code (Title 24, Part 11)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — GREEN BUILDING
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 6 — REFERENCED ORGANIZATIONS AND STANDARDS
- Chapter 7 — INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
- Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
- Appendix A4
▸Appendix A5
Overview- Section A5.101 — GENERAL
- Section A5.102 — DEFINITIONS
- Section A5.103 — SITE SELECTION
- Section A5.104 — SITE PRESERVATION
- Section A5.105 — DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES
- Section A5.106 — SITE DEVELOPMENT
- Section A5.107 — BIRD-FRIENDLY BUILDING DESIGN
- Section A5.201 — GENERAL
- Section A5.202 — DEFINITIONS
- Section A5.203 — PERFORMANCE APPROACH
- Section A5.204 — MANDATORY REQUIREMENTS FOR ALTERATIONS TO EXI…
- Section A5.211 — RESERVED
- Section A5.212 — ELEVATORS, ESCALATORS AND OTHER EQUIPMENT
- Section A5.213 — ENERGY EFFICIENT FRAMING
- Section A5.301 — GENERAL
- Section A5.302 — DEFINITIONS
- Section A5.303 — INDOOR WATER USE
- Section A5.304 — OUTDOOR WATER USE
- Section A5.305 — WATER REUSE
- Section A5.401 — GENERAL
- Section A5.402 — DEFINITIONS
- Section A5.403 — FOUNDATION SYSTEMS
- Section A5.404 — EFFICIENT FRAMING TECHNIQUES
- Section A5.405 — MATERIAL SOURCES
- Section A5.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A5.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A5.409 — LIFE CYCLE ASSESSMENT
- Section A5.501 — GENERAL
- Section A5.502 — DEFINITIONS
- Section A5.504 — POLLUTANT CONTROL
- Section A5.507 — ENVIRONMENTAL COMFORT
- Section A5.508 — OUTDOOR AIR QUALITY
- Appendix A6