Brea Municipal Code Ch. 15.10 Residential Code

Brea Municipal Code · 2026-10 edition · updated 2026-10-04 · Brea

Cite as: Brea Municipal Code Chapter 15.10 · Text as of 2026-10-04

[1]

Editor's Note: Former Ch. 15.10, Residential Code, derived from Ord. 1188; Ord. 1212; Ord. 1232, was repealed by Ord. 1264, 9/16/2025.

§ 15.10.010. 2025 California Residential Code adopted.

The 2025 California Residential Code, including Appendices BF and CI, and incorporating the 2024 International Residential Code as published by the International Code Council, is hereby adopted in its entirety as the Residential Building Code of the City of Brea, together with the amendments, additions, deletions and exceptions set forth in this chapter.

(Ord. 1264, 9/16/2025)

Exceptions & meaning →

§ 15.10.020. 2025 California Residential Code — Amendments.

A. The California Residential Code is hereby amended as follows:

Table R301.2 — Amended.

TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

GROUND SNOW LOAD o WIND DESIGN WIND DESIGN WIND DESIGN WIND DESIGN SEISMIC DESIGN CATEGORY f SUBJECT TO DAMAGE FROM SUBJECT TO DAMAGE FROM SUBJECT TO DAMAGE FROM WINTER DESIGN TEMP e ICE BARRIER UNDERLAYMENT REQUIRED h FLOOD HAZARDS g AIR FREEZING INDEX i MEAN ANNUAL TEMP j
GROUND SNOW LOAD o WIND DESIGN WIND DESIGN WIND DESIGN WIND DESIGN SEISMIC DESIGN CATEGORY f Weathering a Frostline Depth b Termite c WINTER DESIGN TEMP e ICE BARRIER UNDERLAYMENT REQUIRED h FLOOD HAZARDS g AIR FREEZING INDEX i MEAN ANNUAL TEMP j
GROUND SNOW LOAD o Speed d (mph) Topographic effects k Special wind region l Wind borne debris zone m SEISMIC DESIGN CATEGORY f Weathering a Frostline Depth b Termite c WINTER DESIGN TEMP e ICE BARRIER UNDERLAYMENT REQUIRED h FLOOD HAZARDS g AIR FREEZING INDEX i MEAN ANNUAL TEMP j
Zero 95 No No No D 2 or E Negligible 0 Very heavy 43 No See Exhibit B 0 65.1

MANUAL J DESIGN CRITERIA n

Elevation Altitude Correction Factor e Coincident Wet Bulb Indoor Winter Design Dry-Bulb Temperature Indoor Winter Design Dry-Bulb Temperature Outdoor Winter Design Dry-Bulb Temperature Heating Temperature Difference
275 68
Latitude Daily Range Indoor Summer Design Relative Humidity Indoor Summer Design Relative Humidity Indoor Summer Design Dry-Bulb Temperature Outdoor Summer Design Dry-Bulb Temperature Cooling Temperature Difference
34 29

For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.

a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, “negligible,” “moderate” or “severe” for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C 34, ASTM C 55, ASTM C 62, ASTM C 73, ASTM C 90, ASTM C 129, ASTM C 145, ASTM C 216 or ASTM C 652.
b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade.
c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage.
d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(2)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.
e. The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction.
f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1.
g. The jurisdiction shall fill in this part of the table with: the date of the jurisdiction’s entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); (b) and the title and date of the currently effective Flood Insurance Study or other hazard study and maps adopted by the authority having jurisdiction, as amended.
h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with “YES.” Otherwise, the jurisdiction shall fill in this part of the table with “NO.”
i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32°F)” at www.ncdc.noaa.gov/fpsf.html .
j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32°F)” at www.ncdc.noaa.gov/fpsf.html .
k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
l. In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
m. In accordance with Section R301.2.1.2, the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction.
o. The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figure R301.2(3).

B. Section R405.1 Concrete or Masonry Foundations—Exception — Deleted.

C. Section R902.1 Roofing Assemblies — Amended.

R902.1 Roofing assemblies. Roofs shall be covered with materials as set forth in Sections R904 or roof coverings as set forth in R905. Minimum Class A roofing shall be installed in areas designated by this section or where the edge of the roof is less than 3 feet (914 mm) from a lot line. Classes A roofing required by this section to be listed shall be tested in accordance with ASTM E 108 or UL 790. Where required, the roof assembly shall be listed as to class by an approved testing agency. Exceptions:

1. Class A roof assemblies include those with coverings of brick, masonry and exposed concrete roof deck.
2. Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile, or slate installed on noncombustible decks or ferrous, copper or metal sheets installed without a roof deck on noncombustible framing.

D. Section R902.1.2 Roof Coverings in All Other Areas Other Than Fire Hazard Severity Zones or Wildland-Urban Interface — Amended.

R902.1.2 Roof coverings in all other areas. The entire roof covering of every existing structure where more than 33% of the total roof area is replaced within any two-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a fire-retardant roof covering that is at least Class A.

E. Section R902.2 Fire-Retardant-Treated Shingles and Shakes — Amended.

R902.2 Fire-retardant-treated shingles and shakes. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 or ASTM E108 or UL 790 for use on Class A roofs.

F. Appendix BF - Patio Covers — Adopted.

BF105.1 Design Loads. Patio covers shall be designed and constructed to sustain, within the stress limits of the code, all dead loads plus a vertical live load of not less than 20 pounds per square foot (0.48 kN/ m2). Such covers shall be designed to resist the minimum wind loads set forth in Section R301.2.1.

BF105.2 Footings. In areas with frostline depth of zero as specified in the Table R301.2, for patio covers supported on a slab-on-grade without footings, the slab shall conform to the provisions of Sections R506, shall be not less than 5 inches (127 mm) thick and the columns shall not support live and dead loads in excess of 750 pounds (3.34 kN) per columns.

G. Appendix CI - Swimming Pool Safety Act — Adopted.

Appendix CI of the California Residential Code is hereby adopted by reference in its entirety with amendments.

H. Appendix AX of the California Residential Code is hereby adopted by reference in its entirety with amendments.

I. Appendix CI - Swimming Pool Safety Act — Amended.

Authority: Health and Safety Code § 18942(b)

Reference: Health and Safety Code § 18942(b); Chapter 925, Statutes of 1996.

115922

(a) Except as provided in Section 115925, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with item # 1 and at least one additional of the following seven drowning prevention features: Except as provided in Section 115925, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with item # 1 and at least one additional of the following seven drowning prevention features:
1. An enclosure that meets the requirements of Section 115923 and isolates the swimming pool and spa from the private single-family home. Any walls of the residential structure or accessory structures used to complete the isolation enclosure must have door openings equipped with protection as required in Section 115922(a)4 or (a)5. Any such door protection device provided for this purpose may not be used to comply with the second drowning prevention feature requirement.
2. Removable mesh fencing that meets American Society for testing and materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device. The mesh fencing shall be not less than 20 inches from the water's edge
3. An approved safety pool cover, as defined in subdivision (d) of Section 115921.
4. Exit alarms on the private single-family home's doors that provide direct access to the swimming pool or spa. The exit alarm may cause either an alarm noise or a verbal warning, such as a repeating notification that "the door to the pool is open."
5. A self-closing, self-latching device with a release mechanism placed no lower than 54 inches (1,372 mm) above the floor on the private single-family home's doors providing direct access to the swimming pool or spa.
6. An alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM standard F2208 "Standard Safety Specification for Residential Pool Alarms." Which includes surface motion, pressure, sonar, laser and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.
7. Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features set forth above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or that American Society of Mechanical Engineers (ASME).
Before the issuance of a final approval for the completion of permitted construction or remodeling work, the local building code official shall inspect the drowning safety prevention features required by this section and, if no violations are found, shall give final approval.

(Ord. 1264, 9/16/2025)

Exceptions & meaning →