19.28.030 Fire and Smoke Protection Features.¶
Chapter 7 of the 2025 California Building Code is adopted in its entirety subject to the modifications thereto which are set forth below.
Section 711 – Floor and Roof Assemblies.
711.2.3 Supporting construction. The supporting construction shall be protected to afford the required fire-resistance rating of the horizontal assembly supported.
Exception: In buildings of Type IIB, IIIB or VB construction, the construction supporting the horizontal assembly is not required to be fire-resistance rated at the following:
Horizontal assemblies at the separations of incidental uses as specified by Table 509.1 provided that the required fire- resistance rating does not exceed 1 hour.
RESERVED
Horizontal assemblies at the separations of dwelling units and sleeping units as required by Section 420.3.Horizontal assemblies at smoke barriers constructed in accordance with Section 709.