Division 4C.12 — SITE ELEMENTS
Los Angeles Zoning Code — LAMC Chapter 1A · edición 2025 · actualizado 2026-07-08 · Los Angeles
Sec. 4C.12.1. ROOF-MOUNTED EQUIPMENT ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i i i
City of Los Angeles Zoning Code Chapter 1A
i i i
The intent of the standards of this Section (Roof-Mounted Equipment) is to ensure roof-mounted equipment is designed to minimize effects on surrounding properties and the public realm and to
ensure roof-mounted equipment is obscured from view on the City skyline.
B. Applicability
Roof-mounted equipment standards apply to new construction, a major remodel, a site
modifcationi, an exterior modifcationi, or a use modifcationi . When roof-mounted equipment
standards apply, the standards apply to all mechanical equipment or utility equipment located
on a roof. In addition to the screening standards in this Section (Roof-Mounted Equipment),
utilities: wireless facility, rooftop uses shall be designed according to Sec. 4C.12.4. (Wireless
Telecommunication Facilities) .
C. Standards
- Roof-mounted equipment (including but not limited to, compressors, condensers, conduits,
pipes, vents, and ducts) shall be screened on all sides by a parapet or screening structure that:
a. Has an opacity of at least 75 percent;
b. Has a minimum height six inches greater in height than the topmost point of the
equipment; and
c. Encloses the equipment 100 percent up to the minimum height of the screening structure.
- The screening structure shall meet Sec. 4C.7.3. (Fence/Wall Design & Installation) .
i i i
Screening
i i i
i i i
| Col1 | 6” Requ |
|---|---|
| Scre | |
i i i
D. Measurement
For measurement of opacity see Sec. 14.2.13. (Opacity (%)) .
For measurement of enclosure see Sec. 14.2.4. (Enclosure) .
Sec. 4C.12.1. (Roof-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i i i
| 4-178
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
- Height from topmost point of the equipment is measured to the top of the screening structure
at its lowest height.
E. Exceptions
The following are exempt from the standards in this Section (Roof-Mounted Equipment) :
Sustainable energy systems;
Los Angeles Fire Department equipment;
Helipads;
Window cleaning systems; and
Solar panels and their required appurtenances.
F. Relief
- Alternative Compliance to roof-mounted equipment screening standards may be granted in
accordance with Sec. 13B.5.1. (Alternative Compliance) .
- A deviation from any roof-mounted equipment screening dimensional standard of 15 percent
or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any roof-mounted equipment screening standard may be granted as a variance
in accordance with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.1. (Roof-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-179
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.2. GROUND-MOUNTED EQUIPMENT ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i i i
l
i
City of Los Angeles Zoning Code Chapter 1A
i i i
l
i
The intent of the standards of this Section (Ground-Mounted Equipment) is to minimize visibility of
ground mounted equipment from the public realm and support the intent of the applied _Frontage_
District (Part 3B.) .
B. Applicability
- Ground-mounted equipment standards apply to new construction, a major remodel, a
site modifcationi, an exterior modifcationi, or a use modifcationi . When ground-mounted
equipment standards apply, the standards apply to mechanical equipment or utility equipment,
either publicly or privately owned, subject to the following:
a. Ground-mounted equipment standards apply when located at an elevation within six feet
of the surrounding grade, serving five or more dwelling units or at least 5,000 square feet
of foor areal .
C. Standards
- Location
a. Ground-mounted equipment located in a frontage yard shall be installed entirely below
finished grade in a vault.
b. Ground-mounted equipment may be located within a building or structure, such as a
utility room or parking garage, provided no portion of the equipment faces a frontage yard
unobstructed.
c. Ground-mounted equipment may be located outdoors and above-grade provided that it
meets the following standards:
i. No portion of the equipment is located in a frontage yard.
ii. When located on a corner lot, the equipment shall not be located in the parking
setback specified by the applied Frontage District (Part 3B.) .
iii. Equipment is screened with a fence or wall screen that meets the requirements
of Paragraph 2. (Fence/Wall Screen) below, or a landscape screen that meets the
requirements of Paragraph 3. (Landscape Screen) below. Fence,wall, or landscape
screens may be combined to achieve full screening of the subject equipment.
- Fence/Wall Screen
Fences or walls used to meet ground-mounted equipment screening requirements shall meet
the following standards:
i i i
l
i
Sec. 4C.12.2. (Ground-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i i i
l
i
| 4-180
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
a. Form a screening structure that creates a contiguous perimeter around 100 percent of the
subject equipment for a height no less than six inches taller than the topmost point of the
equipment. In no case may the screening structure be less than three feet in height.
i. Shall have a height no less than six inches taller than the topmost point of the
equipment.
ii. Where a screening structure is taller than the minimum height, gates may be no more
than one foot shorter than the height of the wall or fence provided.
iii. In no case shall gates exceed the height of the screening structure by more than one
foot.
iv. Have a minimum opacity of 90 percent.
d. A building wall of an existing or proposed building may serve as a partial element of
the screening structure, provided that the building wall meets the height and opacity
requirements outlined in this Paragraph (Fence/Wall Screen) .
e. Areas within the screening structure shall be maintained free of trash and debris.
f. Screening structure shall comply with Sec. 4C.7.3. (Fence/Wall Design & Installation) .
g. Screening shall comply with any access and clearance standards required by LADWP.
Landscape Screen
Landscaping may be used to meet ground mounted equipment screening requirements
provided it meets the following standards:
Sec. 4C.12.2. (Ground-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-181
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
a. General
City of Los Angeles Zoning Code Chapter 1A
i. Landscape screens shall be composed of hedges meeting the requirements of
Subparagraph b. (Hedges) below, or screening plants meeting the requirements of
Subparagraph c. (Screening Plants) below. Landscape screens may be composed of a
combination of screening plants and hedges.
ii. All required screening plants and hedges shall have a minimum height at maturity no
lower than the height of the topmost point of the equipment subject to screening.
iii. All required screening plants and hedges shall comply with Sec. 4C.6.4. (Plant Design &
Installation) .
iv. Areas within the landscape screen shall be maintained free of trash and debris.
v. All plants provided in a landscape screen shall be planted and maintained so as to
ensure a minimum three-foot clearance between all portions of the equipment and
the plants, based on spread at maturity.
vi. Screening may need to comply with additional access and clearance standards as may
be required by LADWP.
b. Hedges
i. A continuous perimeter of hedge shall surround 100 percent of the subject equipment.
A maximum gap of three feet breaking the continuous perimeter is permitted to allow
for equipment access, provided that the access gap does not face a frontage lot line.
ii. Hedges shall meet the requirements of Sec. 4C.6.4.C.3.d. (Hedges) .
c. Screening Plants
i. Screening plants shall be planted in a planting area no less than three feet in depth that
creates a contiguous perimeter surrounding 100 percent of the subject equipment. A
maximum gap of three feet breaking the contiguous perimeter is permitted to allow
for equipment access, provided that the access gap is not facing a frontage lot line.
ii. A minimum of 20 screening plants shall be planted for every 50 linear feet of planting
area, measured at the outside perimeter of the planting area.
iii. Screening plants shall meet the requirements of Sec. 4C.6.4.C.3.b. (Screening Plants) .
D. Measurement
For measurement of opacity see Sec. 14.2.13. (Opacity (%)) .
Height from topmost point of the equipment is measured to the top of the screen and gate at
their lowest point.
Sec. 4C.12.2. (Ground-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-182
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
- For measurement of plant and hedge height at maturity, see Sec. 4C.6.4.D.11. (Height at
Maturity) .
- For measurement of plant and hedge spread at maturity, see Sec. 4C.6.4.D.3. (Canopy
Diameter, Spread, & Height at Maturity) .
For measurement of planting area width, see Sec. 4C.6.4.D.1. (Planting Area Width) .
For measurement of parking setback see Sec. 3C.2.1.D. (Measurement) .
For measurement of building width see Sec. 2C.5.1.D. (Measurement) .
E. Exceptions
- Ground-mounted equipment standards do not apply to Water and Power assets, as defined in
Sec. 672. (Possession, Management and Control of Water and Power Assets) of the LAAC on
lots owned or leased by the Los Angeles Department of Water and Power.
- Ground-mounted equipment standards do not apply to fire hydrants.
F. Relief
- Where Los Angeles Department of Water and Power determines that mechanical equipment
or utility equipment must be located in the frontage yard and that locating the equipment in a
below grade vault is infeasible for reasons not related to cost, the City may grant an Alternative
Compliance to the ground-mounted equipment location standards in accordance with Sec.
13B.5.1. (Alternative Compliance) allowing for the equipment to be located above-grade and in
a frontage yard.
- A deviation from any ground-mounted equipment screening dimensional standard of 15
percent or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any ground-mounted equipment screening standard may be granted as a
variance in accordance with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.2. (Ground-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-183
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.3. WALL-MOUNTED EQUIPMENT ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i i i
City of Los Angeles Zoning Code Chapter 1A
i i i
The intent of the standards of this Section (Wall-Mounted Equipment) is to ensure wall-mounted equipment is concealed to minimize effects on the public realm.
B. Applicability
- Wall-mounted equipment standards apply to new construction, a major remodel, a site
modifcationi, a use modifcationi, or an exterior modifcationi . When the wall-mounted
equipment standards apply, the standards apply to mechanical equipment or utility equipment
attached or being attached to the exterior wall of a building or structure.
C. Standards
- Location
Wall-mounted electrical meters, gas meters, cable boxes and other utility equipment shall not
be attached to a building facade facing a frontage yard and shall not be located in a frontage
yard unless it is fully screened with a screening structure meeting the standards in Paragraph
2. (Screening Enclosure) below, and that screening structure complies with the frontage yard
fence & wall type standards allowed in the applied Frontage District (Part 3B.) .
- Screening Enclosure
Wall-mounted equipment located on a building or structure facade abutting a frontage yard
shall be screened with a screening structure that meets the following requirements:
a. Has a minimum of 75 percent enclosure for a height of at least six inches taller than
the topmost point of the equipment. For wall-mounted equipment located more than
three feet above the base of the wall, the screening structure shall have a minimum of
75 percent enclosure for no less than six inches below the bottommost point of the
equipment.
b. Has a minimum opacity of 75 percent.
c. Any access gates provided in the screening structure shall meet the following standards:
i. Shall have a height no less than six inches taller than the topmost point of the
equipment and, where located more than three feet above the base of the wall, shall
continue no less than six inches below the bottommost point of the equipment.
ii. Where a screening structure is taller than the minimum height, gates may differ no
more than one foot from the height of the wall or fence provided.
iii. Gates shall not exceed the height of the screening structure by more than one foot.
iv. Shall have a minimum opacity of 90 percent.
d. The screening structure shall comply with Sec. 4C.7.3. (Fence/Wall Design & Installation) .
i i i
Sec. 4C.12.3. (Wall-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i i i
| 4-184
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
D. Measurement
For measurement of opacity see Sec. 14.2.13. (Opacity (%)) .
For measurement of enclosure see Sec. 14.2.4. (Enclosure) .
City of Los Angeles Zoning Code Chapter 1A
- Height from topmost point of the equipment is measured to the top of the screen and gate at
their lowest height.
E. Exceptions
- Wall-mounted equipment standards do not apply to fire alarms.
F. Relief
- An alternative to wall-mounted equipment screening standards may be granted in accordance
with Sec. 13B.5.1. (Alternative Compliance) .
- A deviation from any wall-mounted equipment screening dimensional standard of 10 percent
or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any wall-mounted equipment screening standard may be granted as a variance
in accordance with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.3. (Wall-Mounted Equipment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-185
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.4. WIRELESS TELECOMMUNICATION FACILITIES ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i
City of Los Angeles Zoning Code Chapter 1A
i
The intent of the standards of this Section (Wireless Telecommunication Facilities) is to minimize
visual impacts, make the installation, operation, and appearance of wireless telecommunication
facilities as inconspicuous as possible, to prevent the facility from visually dominating the
surrounding area, and to hide the facility from predominant views visible from surrounding
properties.
B. Applicability
This Section (Wireless Telecommunication Facilities), applies to new construction, a major
remodel, or an exterior modifcationi, involving all wireless telecommunications uses.
C. Standards
Wireless telecommunications facilities shall meet the following standards.
- General
a. All wireless telecommunications facilities shall meet the minimum siting distances to
habitable structures required for compliance with Federal Communications Commission (FCC) regulations and standards governing the environmental effects of radio frequency
emissions.
b. New wireless telecommunication equipment shall be installed at an approved existing
facility, when co-location is feasible.
c. For modifications involving the removal or replacement of transmission equipment or
the collocation of new transmission equipment on existing wireless telecommunication
facilities subject to 47 U.S.C § 1455(a) (Section 6409(a) of the Spectrum Act), see Sec.
4C.12.5. (Existing Wireless Telecommunications Facilities Spectrum Act Compliance
Handbook) .
d. Existing utilities: wireless facility, rooftop, in which new wireless telecommunication
equipment is installed that exceeds the scope of the Spectrum Act, shall be subject to
the standards included in Paragraph 2. (Rooftop Wireless Telecommunications Facilities)
below.
e. Existing utilities: wireless facility, freestanding, in which new wireless telecommunication
equipment is installed that exceeds the scope of the Spectrum Act, shall be subject to the
standards included in Paragraph 3. (Freestanding Wireless Facilities) below.
f. All wireless telecommunication facilities shall be removed within 90 days of
discontinuance of use.
i
Sec. 4C.12.4. (Wireless Telecommunication Facilities) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
| 4-186
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
- Rooftop Wireless Telecommunications Facilities
City of Los Angeles Zoning Code Chapter 1A
Utilities: wireless facility, rooftop, including antennas and any associated equipment shall meet
the following standards:
a. Utilities: wireless facility, rooftop are only allowed where they are a permitted use in the
applied Use District (Part 5B.) .
b. Where located on the rooftop of a designated historic resource or a surveyed historic
resource, utilities: wireless facility, rooftop require review and approval pursuant to Sec.
13B.2.2. (Class 2 Conditional Use Permit) .
c. Shall be located on rooftops no less than 40 feet above grade.
d. Shall be screened on all sides by a parapet or screening structure that meet the standards
provided in Sec. 4C.12.1. (Roof-Mounted Equipment) or Sec. 4C.12.3. (Wall-Mounted
Equipment) .
e. The structure covering the antenna and any equipment cabinet shall be painted and
textured to match the exterior walls of the building.
f. Any wireless antenna structures and associated equipment shall have a height no greater
than 10 feet, measured from rooftop surface at the base of the structures or equipment.
g. Where mounted on the walls of a rooftop enclosure for mechanical equipment or vertical
circulation, wireless antenna structures and associated equipment cabinets shall not
exceed the height of the rooftop enclosure.
h. The cumulative area occupied by all utilities: wireless facility, rooftop and associated
equipment shall not exceed 10 percent of the total area of the rooftop.
- Freestanding Wireless Facilities
Utilities: wireless facility, freestanding, including antennas and any associated equipment shall
meet the following standards:
a. The footing of an antenna shall be structurally designed to support a freestanding wireless
facility which is at least 15 feet higher than the freestanding wireless facility under review in
order to allow a future wireless network to replace an existing freestanding wireless facility
with a new freestanding wireless facility capable of supporting equipment co-location.
b. Freestanding wireless facilities shall not exceed the maximum height specified in the
applied Form District (Part 2B.) .
c. Freestanding wireless facilities shall be set back a minimum distance equal to 20 percent of
the freestanding wireless facility height or 35 feet, whichever is greater, from the following
lot lines:
i. Primary street lot lines and side street lot lines;
Sec. 4C.12.4. (Wireless Telecommunication Facilities) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-187
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
ii. Lot lines shared with a lot that includes a sensitive use; and
City of Los Angeles Zoning Code Chapter 1A
iii. Lot lines shared with a lot with an applied Residential Use District (Div. 5B.3.) or
Agricultural Use District (Div. 5B.2.) .
d. Freestanding wireless facilities shall be screened on all sides with a planting area meeting
the following standards:
i. Has a minimum width of five feet;
ii. Provides screening plants at a frequency of 30 per 50 feet of planting area; and
iii. Provides large species trees at a frequency of three per 50 feet of planting area.
e. All utilities: wireless facility, freestanding uses shall use surfacing and camouflaging
techniques that satisfy the following criteria:
i. Exterior colors, textures, and shapes are visually compatible with the surrounding built
or natural environment;
ii. Exterior finish is non-reflective, unless otherwise required by the Federal Aviation
Administration; and
iii. Situated so as to utilize existing natural or man-made features including topography,
vegetation, buildings, or other structures to provide the greatest amount of visual
screening.
f. The approving authority may require additional measures designed to camouflage a
utilities: wireless facility, freestanding, including placing the facility entirely within a vertical
screening structure. Suitable architectural features include, but are not limited to, clock towers, bell towers, church steeples, icon signs, lighthouses, flagpoles, utility poles, or
faux trees. All facility components, including the antennas, shall be mounted inside said
structure.
g. Freestanding wireless facilities that are not designed according to Subparagraph f. above
shall be of tapered design (three-foot diameter at the base up to 1.5-foot diameter at the
top).
- Existing Wireless Facilities
For the modification of existing wireless telecommunication facilities pursuant to the
Spectrum Act, see Sec. 4C.12.5. (Existing Wireless Telecommunications Facilities Spectrum Act
Compliance Handbook).
D. Measurement
Setbacks from lot lines are measured according to Sec. 2C.2.2.D. (Measurement) .
Planting area width is measured according to Sec. 4C.6.4.D.1. (Planting Area Width) .
Sec. 4C.12.4. (Wireless Telecommunication Facilities) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-188
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
- Planting frequency is measured according to Sec. 14.2.8. (Frequency) .
City of Los Angeles Zoning Code Chapter 1A
- Screening plants are measured as provided or not provided, based on the presence of
screening plants that comply with Sec. 4C.6.4.C.3.b. (Screening Plants) and all other applicable
provisions of Sec. 4C.6.4. (Plant Design & Installation) .
- Large species trees are measured as provided or not provided, based on the presence of large
species trees that comply with Sec. 4C.6.4.C.3.a. (Trees) and all other applicable provisions of
Sec. 4C.6.4. (Plant Design & Installation) .
E. Exceptions
Wireless telecommunication facilities standards do not apply to satellite dish antennae, radio and
television transmitters, and antennae incidental to residential uses.
F. Relief
- Alternative Compliance to wireless telecommunication facilities standards may be granted in
accordance with Sec. 13B.5.1. (Alternative Compliance) .
- A deviation from any wireless telecommunication facilities dimensional standard of 10 percent
or less may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any wireless telecommunication facilities standard may be granted as a
variance in accordance with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.4. (Wireless Telecommunication Facilities) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-189
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
Sec. 4C.12.5. EXISTING WIRELESS TELECOMMUNICATIONS FACILITIES ¶
Esta sección aún no está traducida y se muestra en inglés.
SPECTRUM ACT COMPLIANCE HANDBOOK
A. Intent
The intent of the standards of this Section (Existing Wireless Telecommunications Facilities
Spectrum Act Compliance Handbook) is to ensure the City’s wireless standards, procedures,
and timelines are consistent with Sec. 6409(a) of Title VI. of the Middle Class Tax Relief and Job
Creation Act of 2012 (Spectrum Act) .
B. Applicability
The Existing Wireless Telecommunication Facilities Spectrum Act Compliance Handbook
(Handbook) applies to existing wireless facilities that are applying for Spectrum Act approval.
C. Adoption and Maintenance of the Existing Wireless Telecommunications
Facilities Spectrum Act Compliance Handbook
The Director of Planning, as they deem necessary and appropriate, shall have the authority to
prepare, maintain, amend, and adopt the Handbook . This Handbook explains the standards,
procedures, and timelines of the review of existing wireless telecommunication facilities. The
Director may, as they deem appropriate, use technical consultants or a consultant advisory panel
to update the Handbook in order to comply with changes in federal and state laws.
D. Noncompliance
Failure to comply with the Handbook or any condition or commitments made in compliance with
it is a violation of the Code, subject to all available administrative, criminal and civil remedies.
Sec. 4C.12.5. (Existing Wireless Telecommunications Facilities Spectrum Act Compliance Handbook) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-190
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.6. WASTE RECEPTACLES ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i i
City of Los Angeles Zoning Code Chapter 1A
i i
The intent of the standards of this Section (Waste Receptacles) is to ensure waste receptacle
service areas are designed in a manner that does not detract from the safety, comfort, or
enjoyment of users of the lot, neighboring lots or the public realm.
B. Applicability
This Section (Waste Receptacles) applies to new construction, a major remodel, a site
modifcationi, or an exterior modifcationi . When waste receptacles standards apply, the standards
apply to any solid waste, recycling, or organic waste receptacle 96 gallons in size or greater stored
on a lot.
C. Standards
- Location
a. Waste receptacles and their screening enclosures shall not be located in a frontage yard.
b. Waste receptacles may be located within a building or structure provided they are located
in a room with 100 percent enclosure.
c. Waste receptacles may be located in the same area, room, or enclosure as required
recycling areas as long as the area, room, or enclosure meets both the standards of this
Section (Waste Receptacles) in addition to the recycling areas standards outlined in Sec.
4C.12.7. (Recycling Areas) .
i i
d. Waste receptacle storage areas shall be made accessible to the public right-of-way, a
driveway, or a motor vehicle use area through a pedestrian accessway with a minimum
width of 4 feet in order to accommodate waste hauling services.
- Screening Enclosure
The outdoor waste receptacle shall be screened with a screening structure that meets the
following requirements:
a. Has 100 percent enclosure for a minimum height of six feet, but no less than one foot
taller than the height of the waste receptacles the facility is designed to enclose.
i i
i i
Sec. 4C.12.6. (Waste Receptacles) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i i
| 4-191
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
i
City of Los Angeles Zoning Code Chapter 1A
i
c. Outdoor waste receptacle enclosures located on a lot in a Residential or Agricultural Use
District (Part 5B.) or located on a lot abutting a Residential or Agricultural Use District (Part
5B.) shall be sheltered. The sheltering structure shall meet the following standards:
i. Have a slope of no less than five degrees;
ii. Be made of non-pervious material to ensure runoff; and
iii. Provide a minimum clear height of eight feet under the structure.
d. Wheel stops with a minimum height of eight inches shall be installed a minimum of six
inches from interior walls of waste receptacle screening structures to prevent damage to
walls.
e. Access gates provided in the screening structure shall meet the following standards:
i. Have a height of no less than six feet;
ii. Where a screening structure is seven feet or greater in height, gates may be no more
than one foot shorter than the height of the screening enclosure provided;
iii. In no case shall gates exceed the height of the screening structure by more than one
foot; and
iv. Have a minimum opacity of 90 percent.
f. All provided screening enclosures shall comply with Sec. 4C.7.3. (Fence/Wall Design &
Installation) .
D. Measurement
For frontage yard designation, see Sec. 14.2.16.C.1. (Frontage Yard) .
For measurement of height, see Sec. 4C.7.1.D. (Measurement) .
For measurement of enclosure, see Sec. 14.2.4. (Enclosure) .
For measurement of opacity, see Sec. 14.2.13. (Opacity (%)) .
E. Exceptions
- Waste receptacles standards do not apply to lots containing only residential uses and four or
fewer dwelling units.
- Use modifcationi project activities on a site having less than 2,500 square feet of lot area shall
be exempt from waste receptacle screening and enclosure standards in this Section (Waste
Receptacles) .
i
Sec. 4C.12.6. (Waste Receptacles) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
| 4-192
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
F. Relief
City of Los Angeles Zoning Code Chapter 1A
- Alternative Compliance to waste receptacle standards may be granted in accordance with Sec.
13B.5.1. (Alternative Compliance) .
- A deviation from any waste receptacle dimensional standard of 15 percent or less may be
granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any waste receptacle standard may be granted as a variance in accordance
with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.6. (Waste Receptacles) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-193
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.7. RECYCLING AREAS ¶
Esta sección aún no está traducida y se muestra en inglés.
i
l
l
l
l
City of Los Angeles Zoning Code Chapter 1A
i
l
l
l
l
A recycling area is an outdoor enclosure or a room within a building which is designated for the
collection of recyclable materials generated by the use(s) on a lot.
A. Intent
The intent of the standards of this Section (Recycling Areas) is to ensure that adequate facilities
for collecting and loading recyclable materials are provided in order to divert solid waste, address
source reduction, and facilitate recycling and composting activities by users, tenants, and
residents.
B. Applicability
- Recycling area standards apply to new construction or a site modifcationi which introduces or
modifies a recycling area on a lot and results in any of the following:
a. A 25 percent increase in foor areal for residential projects with four or more dwelling units,
or a 30 percent increase of foor areal for non-residential projects;
b. Marinas where the foor areal includes the space dedicated to the docking or mooring of
marine vessels; or
c. Any site where multiple building permits are issued within a 12-month period that result in
the addition of foor areal beyond the above thresholds.
C. Standards
- General
a. Recycling areas shall be equipped with recycling receptacle containers that are sheltered,
durable, waterproof, rustproof, and of incombustible construction, and that either
provide protection against the environment or are located in a building or structure that is
sheltered and enclosed. Containers must be clearly labeled to indicate the type of material
to be deposited, and all recyclable materials must be placed or stored in such containers.
b. When a project provides a trash chute, including adding a trash chute to an existing
development, a recycling chute shall also be provided. Recycling chutes shall be clearly
marked "recycling only" at every point of entry.
c. Outdoor recycling areas shall be constructed with a concrete floor sloped to drain, and a
water faucet for hose attachment shall be located adjacent to or within the enclosure.
d. The recycling area shall be clearly identified by one or more signs with a minimum
dimension of 16 inches by 20 inches that designate the area for recycling collection and
loading.
e. The recycling area shall be available for use by persons residing or employed on the
property.
i
l
l
l
l
Sec. 4C.12.7. (Recycling Areas) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
l
l
l
l
| 4-194
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
f. No payment shall be made to persons depositing recycling materials in the recycling area
and no processing of recycling materials shall be permitted within the recycling area.
For recyclable materials deposited or redeemed for monetary value, see Sec. 5D.9.4.A. (Collection) . For sorting or processing of recyclable materials from off-site sources, see
Sec. 5D.9.4.B. (Sorting & Processing) .
g. Each property owner or lessee shall contract with a recycler or hauler for the pick-up of
recyclable materials, separate from trash collection, when receptacles are full or every week, whichever occurs first.
h. To encourage active participation in recycling to the maximum extent possible, each
property owner, manager, or lessee shall inform all tenants and/or employees living or
working on the property of the availability and location of the recycling area(s), the types
of materials that are collected for recycling, and that the recycling collection facilities
are located on the property pursuant to state law requiring the diversion of a substantial
portion of solid waste.
i. No toxic or hazardous material shall be stored in recycling areas or receptacles.
j. Recycling areas shall be kept free of litter, debris, spillage, bugs, rodents, odors, and other
similar undesirable hazards.
k. Recycling receptacle containers shall be covered, durable, waterproof, rustproof, and of
incombustible construction, and shall provide protection against the environment or be in
completely enclosed indoor recycling areas. Containers shall be clearly labeled to indicate
the type of material to be deposited.
- Location
a. Outdoor recycling areas and their screening enclosures shall not be located in a frontage
yard.
b. Recycling areas may be located within a building or structure provided they have 100
percent enclosure.
c. Recycling areas shall be placed within 10 feet of waste receptacles or waste receptacle
service areas or rooms wherever feasible. Where multiple recycling areas are provided, at
least one recycling area must be placed within 10 feet of at least one waste receptacle or
waste receptacle service area or room.
d. Recycling areas may be located in the same area, room, or enclosure as waste receptacles
as long as the area, room, or enclosure meets both the recycling area standards in this
Section and the waste receptacle standards outlined in Sec. 4C.12.6. (Waste Receptacles) .
e. Recycling areas shall not diminish the required number of automobile parking stalls or
bicycle parking spaces or impair traffic flow.
Sec. 4C.12.7. (Recycling Areas) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-195
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
- Size
l
l
l
City of Los Angeles Zoning Code Chapter 1A
l
l
l
a. For residential uses with 20 or fewer dwelling units or any other uses with a total foor areal
of less than 3,000 square feet, the minimum area of the required recycling area shall be 30
square feet.
b. For residential uses of 21 to 50 dwelling units or any other uses having a total foor areal
of 3,001 to 7,500 square feet, the minimum area of the required recycling area shall be 60
square feet.
c. For residential uses of 51 or more dwelling units, or any other uses having a total foor areal
of greater than 7,500 square feet, the minimum area of the required recycling area shall be
100 square feet.
d. No individual recycling area shall exceed an area of 300 square feet.
e. Multiple recycling areas on the same lot may be combined to meet the applicable required
minimum area, as long as no individual recycling area has an area of less than 30 feet and
the total combined area of the provided recycling areas does not exceed 300 square feet.
f. Every recycling area shall contain a minimum clear height of at least eight feet.
g. The recycling area shall be of adequate size for the collection of all recyclable materials
generated by the use(s) occupying the lot, without such materials overflowing the area or forcing significant amounts of recycling to be discarded as general refuse, or the
Department of Building and Safety may require a larger space for the recycling area in
excess of the minimum requirements listed in Subparagraph a. through Subparagraph c .
above to meet the intent of this Subparagraph .
- Screening Enclosure
Outdoor recycling areas shall be screened with a screening structure that meets the following
requirements:
a. Has 100 percent enclosure for a minimum height of six feet; and
l
l
l
l
l
l
l
l
l
c. Access gates provided in the screening structure shall meet the following standards:
l
l
l
Sec. 4C.12.7. (Recycling Areas) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
l
l
l
| 4-196
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
i. Have a height of no less than six feet;
City of Los Angeles Zoning Code Chapter 1A
ii. Where a screening structure is seven feet or greater in height, any gate is no more than
one foot shorter than the height of the screening structure provided;
iii. Does not exceed the height of the screening structure by more than one foot; and
iv. Have a minimum opacity of 90 percent.
d. All provided screening structures shall comply with Sec. 4C.7.3. (Fence/Wall Design &
Installation) .
D. Measurement
For frontage yard designation, see Sec. 14.2.16.C.1. (Frontage Yard) .
For measurement of height, see Sec. 4C.7.1.D. (Measurement) .
For measurement of enclosure, see Sec. 14.2.4. (Enclosure) .
For measurement of opacity, see Sec. 14.2.13. (Opacity (%)) .
E. Relief
- Alternative compliance to recycling receptacle standards may be granted in accordance with
Sec. 13B.5.1. (Alternative Compliance) .
- A deviation from any recycling receptacle dimensional standard of 15 percent or less may be
granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any recycling receptacle standard may be granted as a variance in accordance
with Sec. 13B.5.3. (Variance) .
Sec. 4C.12.7. (Recycling Areas) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-197
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
Sec. 4C.12.8. SHOPPING CART CONTAINMENT ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i i
City of Los Angeles Zoning Code Chapter 1A
i i
The intent of the standards of this Section (Shopping Cart Containment) is to prevent or reduce
the accumulation of abandoned shopping carts in the City, which may obstruct pedestrian and vehicular traffic, and constitute a hazard to the health, safety, and general welfare of the public.
B. Applicability
Shopping cart containment requirements apply to projects involving new construction, site
modifcationi, use modifcationi, and renovation for commercial uses established in Div. 5D.1.5.
(General Commercial Uses) that provide six or more shopping carts.
C. Standards
- General
a. Shopping Cart Noticing
Every shopping cart owned or provided by any business establishment in the City shall have a notice permanently affixed to it that:
i. Identifies the owner of the shopping cart or the name of the business establishment,
or both;
ii. Notifies the public of the procedure to be utilized for authorized removal of the
shopping cart from the business premises;
iii. Notifies the public that the unauthorized removal of the shopping cart from the
premises or parking area of the business establishment is a violation of state and City
law;
iv. Lists a telephone number to contact to report the location of the abandoned shopping
cart; and
v. Lists an address for returning the shopping cart to the owner or business
establishment.
b. Shopping Cart Collection Areas
Shopping cart corrals and/or storage areas shall be provided with a minimum width of five
feet and minimum depth of 15 feet, but shall not be located within a required frontage
yard.
c. Signs
Signs that warn customers that shopping cart removal is prohibited and constitutes a violation of California Business and Professions Code, Sec. 22435.1. (Identification of
Shopping and Laundry Carts) and Chapter IV. (Public Welfare), Sec. 41.45. (Unauthorized
i i
Sec. 4C.12.8. (Shopping Cart Containment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i i
| 4-198
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
City of Los Angeles Zoning Code Chapter 1A
Removal, Use Or Possession of Shopping Carts) of this Code shall be installed and
maintained at exits, shopping cart collection areas, and any vehicular or pedestrian
accessways. Signs shall be no less than 16 inches by 20 inches, and placed at a minimum
height of three feet and a maximum height of six feet.
- Containment Methods
A project shall include a practical containment approach with one or more of the following
containment methods to ensure that shopping carts remain on the premises.
a. Wheel Locking or Stopping Mechanisms
Shopping carts shall be equipped with a wheel locking or stopping mechanism that is used
in conjunction with an electronic magnetic barrier along the perimeter of the commercial
use or lot, including customer entrances, loading areas, basements, landscaped areas,
along crossings and access points required for driveways, drive aisles, pedestrian accessways, and pedestrian passageways, or any other perimeter identified on a shopping
cart containment plan. The wheel locking or stopping mechanism must activate when the
shopping cart crosses the electronic or magnetic barrier.
b. Screening Plants
An F-Screen 1 (Sec. 4C.8.1.C.2.a.) shall be provided along the perimeter of the commercial use or lot, or any other perimeter identified on a shopping cart containment plan.
c. Bollards
Bollards shall be installed at customer entrances, or within 10 feet of the entrances, and
shall be spaced at a maximum distance of 17 inches from each other or nearby enclosed
space.
d. Other Methods
Other methods for shopping cart containment may be used, so long as the Department of Public Works, Bureau of Sanitation has approved the system or method as effectively
containing or controlling shopping carts on the premises.
- Performance Standards
Owners shall do all of the following and execute and record a covenant to the satisfaction of
the Department of Public Works, Bureau of Sanitation to ensure compliance by the owner and
any leasee:
a. Daily After Hours Cart Containment
Prepare and maintain a plan for securing shopping carts whenever the store is not open
for business.
Sec. 4C.12.8. (Shopping Cart Containment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-199
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.12. (Site Elements)
b. Shopping Cart Retrieval
City of Los Angeles Zoning Code Chapter 1A
Retrieve their carts or provide evidence of a contract with a shopping cart retrieval
service with terms requiring collection of abandoned shopping carts within 24 hours of notification of an abandoned shopping cart.
c. Employee Training
Implement and maintain a periodic training program for its new and existing employees
designed to educate employees about the abandonment and retrieval of shopping carts of
the retail.
d. Shopping Cart Containment Plan
A shopping cart containment plan shall be prepared that identifies areas on a lot where shopping carts can be removed from the lot and identifies the proposed containment
method for each area.
D. Measurement
[Reserved].
E. Relief
- Alternative Compliance to the shopping cart containment standards established in this Section
(Shopping Cart Containment) may be granted in accordance with Sec. 13B.5.1. (Alternative
Compliance) .
- A deviation from any shopping cart containment dimensional standard of 10 percent or less
may be granted in accordance with Sec. 13B.5.2. (Adjustment) .
- A deviation from any shopping cart containment standard may be granted as a variance in
accordance with Sec. 13B.5.3. (Variance) .
F. Enforcement
Regardless of Div. 13B.10. (Department of Building and Safety), the Department of Public Works,
Bureau of Sanitation shall have the authority and responsibility to enforce the provisions of this
Section (Shopping Cart Containment) .
Sec. 4C.12.8. (Shopping Cart Containment) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 4-200
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 4C.13. (Environmental Protection)