Skip to content

Trinidad · Zoning · SR

Trinidad SR zoning: height, setbacks and lot size

In Trinidad's SR zone, generally buildings can be up to 25 ft tall, the front setback is 30 ft and the minimum lot size is 20,000 sq ft, with the conditions listed below (Trinidad code, read October 2026).

Key points

  • Maximum building height: 25 ft (the planning commission may require a lesser height)
  • Minimum front setback: 30 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: 20,000 sq ft (When a septic tank is to be the means of wastewater disposal)

SR is a zoning district in Trinidad. Every value below was read from the Trinidad Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in SR

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
25 ft
Applies: the planning commission may require a lesser height
§ 17.28.070 · code text
Maximum building height in the SR zone is 25 feet, except that the planning commission may require a lesser height as provided in Chapter 17.60 TMC.
Minimum front setback
30 ft
§ 17.28.060 · code text
Front, 30 feet;
Minimum side setback
10 ft
§ 17.28.060 · code text
Side, 10 feet.
Minimum rear setback
20 ft
§ 17.28.060 · code text
Rear, 20 feet;
Minimum lot size
20,000 sq ft
Applies: When a septic tank is to be the means of wastewater disposal
§ 17.28.040 · code text
In no case shall a lot be less than 20,000 square feet in area.

Not on this page

We did not find a general stories, lot coverage, FAR, density limit for SR in the zoning tables we read. The code may still set one elsewhere — check the Trinidad Municipal Code.

Other Trinidad zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Trinidad's SR zone?

25 ft (the planning commission may require a lesser height) — Trinidad Municipal Code § 17.28.070.

What is the minimum front setback in Trinidad's SR zone?

30 ft — Trinidad Municipal Code § 17.28.060.

What is the minimum side setback in Trinidad's SR zone?

10 ft — Trinidad Municipal Code § 17.28.060.

What is the minimum rear setback in Trinidad's SR zone?

20 ft — Trinidad Municipal Code § 17.28.060.

What is the minimum lot size in Trinidad's SR zone?

20,000 sq ft (when a septic tank is to be the means of wastewater disposal) — Trinidad Municipal Code § 17.28.040.

General information, not legal advice.

Ask about a Trinidad property in SR

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Trinidad