Skip to content

Sutter Creek · Zoning · R-1

Sutter Creek R-1 zoning: height, setbacks and lot size

In Sutter Creek's R-1 zone, buildings can be up to 35 ft tall and the front setback is 25 ft (Sutter Creek code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 25 ft
  • Minimum side setback: 5 ft (12 ft on the street side of corner lots)
  • Minimum rear setback: 15 ft
  • Maximum lot coverage: 50%
  • Maximum density: 6.22 units per acre (dependent upon site conditions and constraints)

R-1 (One Family Dwelling) is a zoning district in Sutter Creek. Every value below was read from the Sutter Creek Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 18.16.030 · code text
Maximum building height in the R-1 zone shall be limited to two and one-half stories and shall not exceed thirty-five feet.
Minimum front setback
25 ft
§ 18.16.040 · code text
There shall be a front yard of not less than twenty-five feet.
Minimum side setback
5 ft
Applies: 12 ft on the street side of corner lots
§ 18.16.050 · code text
There shall be a side yard of not less than five feet except that on the street side of corner lots there shall be a side yard of not less than twelve feet.
Minimum rear setback
15 ft
§ 18.16.060 · code text
There shall be a rear yard of not less than fifteen feet
Maximum lot coverage
50%
§ 18.16.090 · code text
Building lot coverage shall not exceed fifty percent of the lot area.
Maximum density
6.22 units per acre
Applies: dependent upon site conditions and constraints
§ 18.16.100 · code text
Maximum development density shall be up to 6.22 units per acre, as established in City of Sutter Creek General Plan Land Use Element Table 4-3, and dependent upon site conditions and constraints.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-1:

  • Minimum side setback: 12 ft — street side of corner lots § 18.16.050

Not on this page

We did not find a general stories, lot size, FAR limit for R-1 in the zoning tables we read. The code may still set one elsewhere — check the Sutter Creek Municipal Code.

Other Sutter Creek zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Sutter Creek's R-1 zone?

35 ft — Sutter Creek Municipal Code § 18.16.030.

What is the minimum front setback in Sutter Creek's R-1 zone?

25 ft — Sutter Creek Municipal Code § 18.16.040.

What is the minimum side setback in Sutter Creek's R-1 zone?

5 ft (12 ft on the street side of corner lots) — Sutter Creek Municipal Code § 18.16.050.

What is the minimum rear setback in Sutter Creek's R-1 zone?

15 ft — Sutter Creek Municipal Code § 18.16.060.

What is the maximum lot coverage in Sutter Creek's R-1 zone?

50% — Sutter Creek Municipal Code § 18.16.090.

General information, not legal advice.

Ask about a Sutter Creek property in R-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Sutter Creek