Skip to content

Santa Barbara · Zoning · C-P

Santa Barbara C-P zoning: height, setbacks and lot size

In Santa Barbara's C-P zone, generally buildings can be up to 45 ft (3 stories) tall, the front setback is 10 ft and the minimum lot size is None required, with the conditions listed below (Santa Barbara code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Maximum number of stories: 3 stories
  • Minimum front setback: 10 ft
  • Minimum side setback: None required (Nonresidential or mixed use buildings or structures abutting a nonresidentially-zoned parcel)
  • Minimum lot size: None required (buildings or parts used only for dwellings follow the R-4 zone)

C-P (RESTRICTED COMMERCIAL ZONE) is a zoning district in Santa Barbara. Every value below was read from the Santa Barbara Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-P

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
§ 28.54.050 · code text
Three stories and not exceeding 45 feet.
Maximum number of stories
3 stories
§ 28.54.050 · code text
Three stories and not exceeding 45 feet.
Minimum front setback
10 ft
§ 28.54.060 · code text
A front setback of not less than 10 feet shall be provided between the front lot line and all buildings, structures and parking on the lot.
Minimum side setback
None required
Applies: Nonresidential or mixed use buildings or structures abutting a nonresidentially-zoned parcel
§ 28.54.060 · code text
Nonresidential or mixed use buildings or structures: No setback required.
Minimum lot size
None required
Applies: buildings or parts used only for dwellings follow the R-4 zone
§ 28.54.080 · code text
None, except all buildings or portions thereof used exclusively for dwelling purposes shall comply with the provisions of the R-4 Zone.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-P:

  • Minimum side setback: 10 ft or one-half building height, whichever is greater — All buildings and structures abutting a residentially-zoned parcel § 28.54.060

Not on this page

We did not find a general rear setback, lot coverage, FAR, density limit for C-P in the zoning tables we read. The code may still set one elsewhere — check the Santa Barbara Municipal Code.

Other Santa Barbara zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Santa Barbara's C-P zone?

45 ft — Santa Barbara Municipal Code § 28.54.050.

What is the maximum number of stories in Santa Barbara's C-P zone?

3 stories — Santa Barbara Municipal Code § 28.54.050.

What is the minimum front setback in Santa Barbara's C-P zone?

10 ft — Santa Barbara Municipal Code § 28.54.060.

What is the minimum side setback in Santa Barbara's C-P zone?

None required (nonresidential or mixed use buildings or structures abutting a nonresidentially-zoned parcel) — Santa Barbara Municipal Code § 28.54.060.

What is the minimum lot size in Santa Barbara's C-P zone?

None required (buildings or parts used only for dwellings follow the R-4 zone) — Santa Barbara Municipal Code § 28.54.080.

General information, not legal advice.

Ask about a Santa Barbara property in C-P

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Santa Barbara