Skip to content

San Pablo · Zoning · EMU

San Pablo EMU zoning: height, setbacks and lot size

In San Pablo's EMU zone, generally buildings can be up to 60 ft tall, the front setback is None required and the minimum lot size is No minimum, with the conditions listed below (San Pablo code, read October 2026).

Key points

  • Maximum building height: 60 ft
  • Minimum front setback: None required
  • Minimum side setback: None required (10 ft where the side abuts a residential district or a conforming residential use)
  • Minimum rear setback: None required (10 ft where the rear of the parcel abuts a residential district or a residential use)
  • Minimum lot size: No minimum (Minimum parcel size of 0.25 acres required for multifamily residential uses.)
  • Maximum floor area ratio (FAR): 0.6 (nonresidential uses only; no applicable FAR maximum for residential uses)
  • Maximum density: 60 du/ac

EMU is a zoning district in San Pablo. Every value below was read from the San Pablo Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in EMU

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
60 ft
§ 17.34.040 · code text
Table row “Maximum building height (feet)”, column “EMU”: 60
Minimum front setback
None required
§ 17.34.040 · code text
No front yard setback is required.
Minimum side setback
None required
Applies: 10 ft where the side abuts a residential district or a conforming residential use
§ 17.34.040 · code text
No side yard setback is required except where the side of a parcel abuts the side of a parcel in a residential district or a parcel on which a conforming residential use is located, in which case the side yard shall be not less than ten feet.
Minimum rear setback
None required
Applies: 10 ft where the rear of the parcel abuts a residential district or a residential use
§ 17.34.040 · code text
No rear yard setback is required except where the rear of a parcel abuts a residential district or a parcel on which a residential use is located, in which case the rear yard shall not be less than ten feet.
Minimum lot size
No minimum
Applies: Minimum parcel size of 0.25 acres required for multifamily residential uses.
§ 17.34.040 · code text
Table row “Minimum parcel area (sf)”, column “EMU”: No minimum 3
Maximum floor area ratio (FAR)
0.6
Applies: nonresidential uses only; no applicable FAR maximum for residential uses
§ 17.34.040 · code text
Table row “Maximum floor area ratio (FAR)”, column “EMU”: 0.6 4
Maximum density
60 du/ac
§ 17.34.040 · code text
Table row “Maximum density (du/ac)”, column “EMU”: 60

Uses in EMU

Uses the code's use tables allow in EMU, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in EMU:

  • Minimum side setback: 10 ft — where the side of a parcel abuts the side of a parcel in a residential district or a parcel on which a conforming residential use is located § 17.34.040
  • Minimum rear setback: 10 ft — where the rear of a parcel abuts a residential district or a parcel on which a residential use is located § 17.34.040

Not on this page

We did not find a general stories, lot coverage limit for EMU in the zoning tables we read. The code may still set one elsewhere — check the San Pablo Municipal Code.

Other San Pablo zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in San Pablo's EMU zone?

60 ft — San Pablo Municipal Code § 17.34.040.

What is the minimum front setback in San Pablo's EMU zone?

None required — San Pablo Municipal Code § 17.34.040.

What is the minimum side setback in San Pablo's EMU zone?

None required (10 ft where the side abuts a residential district or a conforming residential use) — San Pablo Municipal Code § 17.34.040.

What is the minimum rear setback in San Pablo's EMU zone?

None required (10 ft where the rear of the parcel abuts a residential district or a residential use) — San Pablo Municipal Code § 17.34.040.

What is the minimum lot size in San Pablo's EMU zone?

No minimum (minimum parcel size of 0.25 acres required for multifamily residential uses) — San Pablo Municipal Code § 17.34.040.

General information, not legal advice.

Ask about a San Pablo property in EMU

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on San Pablo