In San Carlos's RM-100 zone, generally buildings can be up to 60 ft (5 stories) tall, the front setback is 15 ft and the minimum lot size is 10,000 sq ft, with the conditions listed below (San Carlos code, read October 2026).

Key points

  • Maximum building height: 60 ft
  • Maximum number of stories: 5 stories
  • Minimum front setback: 15 ft (Where 75% or more of lots in a block, both sides of the street, are built: the average of those lots if under 15 ft.)
  • Minimum side setback: 5 ft
  • Minimum rear setback: 15 ft
  • Minimum lot size: 10,000 sq ft (New subdivision lots must follow Table 17.16.030.)
  • Maximum lot coverage: 75%
  • Maximum floor area ratio (FAR): No maximum FAR (For residential buildings.)
  • Maximum density: 100 units per acre

RM-100 (Residential Multifamily District) is a zoning district in San Carlos. Every value below was read from the San Carlos Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RM-100

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
60 ft
§ 18.04.050 · code text
Table row “Maximum Height”, column “RM-100”: 60 ft. (A)
Maximum number of stories
5 stories
§ 18.04.050 · code text
Table row “Maximum Stories”, column “RM-100”: 5 (B)
Minimum front setback
15 ft
Applies: Where 75% or more of lots in a block, both sides of the street, are built: the average of those lots if under 15 ft.
§ 18.04.050 · code text
Table row “Front”, column “RM-100”: 15 ft. (C)
Minimum side setback
5 ft
§ 18.04.050 · code text
Table row “Interior Side”, column “RM-100”: 5 ft. (A)
Minimum rear setback
15 ft
§ 18.04.050 · code text
Table row “Rear”, column “RM-100”: 15 ft. (A)
Minimum lot size
10,000 sq ft
Applies: New subdivision lots must follow Table 17.16.030.
§ 18.04.050 · code text
Table row “Minimum Lot Size (sq. ft.)”, column “RM-100”: 10,000*
Maximum lot coverage
75%
§ 18.04.050 · code text
Table row “Maximum Lot Coverage (Percent of Lot)”, column “RM-100”: 75%
Maximum floor area ratio (FAR)
No maximum FAR
Applies: For residential buildings.
§ 18.04.050 · code text
Table row “Maximum Floor Area Ratio (FAR)”, column “RM-100”: No maximum FAR for residential buildings.
Maximum density
100 units per acre
§ 18.04.050 · code text
Table row “Maximum Density (units/net acre)”, column “RM-100”: 100

Uses in RM-100

Uses the code's use tables allow in RM-100, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in RM-100:

  • Maximum building height: 28 ft — at the rear setback line where adjacent to an RS district § 18.04.050
  • Maximum building height: 28 ft — at the side setback line facing an RS district § 18.04.050
  • Minimum side setback: 10 ft — from an RS boundary; side transition § 18.04.050
  • Minimum rear setback: 20 ft — where adjacent to an RS district; rear transition § 18.04.050

Other San Carlos zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in San Carlos's RM-100 zone?

60 ft — San Carlos Municipal Code § 18.04.050.

What is the maximum number of stories in San Carlos's RM-100 zone?

5 stories — San Carlos Municipal Code § 18.04.050.

What is the minimum front setback in San Carlos's RM-100 zone?

15 ft (where 75% or more of lots in a block, both sides of the street, are built: the average of those lots if under 15 ft) — San Carlos Municipal Code § 18.04.050.

What is the minimum side setback in San Carlos's RM-100 zone?

5 ft — San Carlos Municipal Code § 18.04.050.

What is the minimum rear setback in San Carlos's RM-100 zone?

15 ft — San Carlos Municipal Code § 18.04.050.