In Richmond's IW zone, generally buildings can be up to 100 ft tall and the front setback is 10 ft, with the conditions listed below (Richmond code, read October 2026).
Key points
- Maximum building height: 100 ft
- Minimum front setback: 10 ft (from local streets)
- Minimum side setback: 0 ft (10 ft where abutting an RL, PCI or PR district (5 ft with a solid fence))
- Minimum rear setback: 0 ft (15 ft where abutting an RL, PCI or PR district)
- Maximum floor area ratio (FAR): 0.5
IW is a zoning district in Richmond. Every value below was read from the Richmond Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in IW
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 100 ft § 15.04.204.030 · code textTable row “Maximum Height (ft.)”, column “IW”: 100 |
|---|---|
| Minimum front setback | 10 ft Applies: from local streets § 15.04.204.030 · code textTable row “Front”, column “IW”: 10 from local streets; 25 from Collector streets |
| Minimum side setback | 0 ft Applies: 10 ft where abutting an RL, PCI or PR district (5 ft with a solid fence) § 15.04.204.030 · code textTable row “Interior Side”, column “IW”: 0; 10 where abutting an RL, PCI, or PR district (5 with solid fence) |
| Minimum rear setback | 0 ft Applies: 15 ft where abutting an RL, PCI or PR district § 15.04.204.030 · code textTable row “Rear”, column “IW”: 0; 15 where abutting an RL, PCI, or PR district into Yards |
| Maximum floor area ratio (FAR) | 0.5 § 15.04.204.030 · code textTable row “Maximum Floor Area Ratio (FAR)”, column “IW”: 0.5; up to 1.0 with an approval of a CUP |
When a different number applies
The code sets other values for particular lots, buildings or locations in IW:
- Minimum front setback: 25 ft — from Collector streets § 15.04.204.030
- Minimum side setback: 10 ft — Where abutting an RL, PCI, or PR district; 5 ft with a solid fence § 15.04.204.030
- Minimum rear setback: 15 ft — Where abutting an RL, PCI or PR district § 15.04.204.030
- Maximum floor area ratio (FAR): 1.0 — with an approval of a CUP § 15.04.204.030
Not on this page
We did not find a general stories, lot size, lot coverage, density limit for IW in the zoning tables we read. The code may still set one elsewhere — check the Richmond Municipal Code.
Other Richmond zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Richmond's IW zone?
100 ft — Richmond Municipal Code § 15.04.204.030.
What is the minimum front setback in Richmond's IW zone?
10 ft (from local streets) — Richmond Municipal Code § 15.04.204.030.
What is the minimum side setback in Richmond's IW zone?
0 ft (10 ft where abutting an RL, PCI or PR district (5 ft with a solid fence)) — Richmond Municipal Code § 15.04.204.030.
What is the minimum rear setback in Richmond's IW zone?
0 ft (15 ft where abutting an RL, PCI or PR district) — Richmond Municipal Code § 15.04.204.030.
What is the maximum floor area ratio (far) in Richmond's IW zone?
0.5 — Richmond Municipal Code § 15.04.204.030.
General information, not legal advice.
Ask about a Richmond property in IW
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question