Local zoning · Rancho Cordova

Rancho Cordova — Parking

Parking under the Rancho Cordova local zoning and planning code, with the controlling citations.

Last reviewed: July 2, 2026

Overview

This page summarizes how the City of Rancho Cordova regulates off‑street motor vehicle parking, bicycle parking, and loading under the local zoning code (Title 23). The city’s rules set required minimums by use (Table 23.719‑1), add design and location limits for residential driveways and parking, require bicycle parking and loading where appropriate, and provide reductions and waivers for transit‑served and multi‑modal projects. See the city zoning rules for the detailed tables and design provisions in § 23.719.010 – § 23.719.170 . (For how parking interacts with building systems and accessibility, confirm applicable items in the California Building Standards Code.) Also review the city’s development standards and design review rules early in design.

How Rancho Cordova’s parking rules are organized (quick map)

  • Applicability and purpose: § 23.719.010–.020 (chapter purpose; applies to new development, changes of use, and major modifications) .
  • Vehicle minimums: required vehicle ratios by use are in Table 23.719‑1 and administered from § 23.719.070 (minimums) and § 23.719.040 (calculations/rounding) .
  • Residential special rules (driveways, front‑yard parking, space size): § 23.719.130 and § 23.719.060 (dimensions and setbacks) .
  • Bicycle parking standards: § 23.719.110 (types, dimensions, surfacing, exemptions) .
  • Loading / maneuvering: § 23.719.150 (how many, size, location) and related diagrams .
  • EV readiness: the city integrates CALGreen / Title 24 requirements via § 23.719.160 and enforces EV‑capable infrastructure per the California Green Building Standards Code; see the city section for details and California Building Standards Code references .
  • Reductions and waivers (transit proximity, extra bicycle parking, parking districts): § 23.719.080 (reductions and exceptions) .

District-by-district notes (how parking rules apply in key Rancho Cordova zoning districts)

The city lists base and overlay zones in Table 23.301‑1; parking requirements are applied to the uses in those zones using Table 23.719‑1 and the design rules of Chapter 23.719. Below are focused summaries for the most common project contexts. For exact parcel zoning consult the city zoning map and confirm with the director for boundary questions (see § 23.301.030) .

RD‑20 (Residential, 20 du/ac) — typical medium‑density residential

  • Purpose & where it applies: a medium density residential base zone implementing the General Plan; listed in Table 23.301‑1 as a residential zone (see the zoning districts table) .
  • Typical permitted uses: townhouses, small‑lot multifamily; accessory units where allowed. Development standards for multifamily objective design and site planning (including orientation of parking) are in Chapters 23.707 and Article 5 mixed‑use standards when applicable .
  • Parking rules: parking per unit is measured by the dwelling type in Table 23.719‑1 (e.g., studio/1‑bed = 1 space/unit; 2–3 beds = 2 spaces/unit; plus guest ratio 0.2/unit where shown), and bicycle parking also required per § 23.719.110 .
  • Key dimensional/development notes: parking areas and structures must follow Chapter 23.719 design standards and objective multifamily standards (location of parking relative to street; parking not placed on primary street frontages for neighborhood compatibility) .

RMU (Residential Mixed‑Use) — compact mixed housing in village centers

  • Purpose & where it applies: mixed‑use districts intended to concentrate residential above or next to ground‑floor commercial uses (Table 23.301‑1) .
  • Typical permitted uses: ground‑floor retail/office, upper‑floor dwellings, live/work. Development standards for RMU are in the mixed‑use article (see Table 23.313‑2) .
  • Parking rules: uses are parked according to the specific land‑use categories in Table 23.719‑1 (retail, office, residential each have their own ratios), and where multiple uses share a building the parking requirement is the sum of each use’s requirement (see § 23.719.150 for loading; § 23.719.040 for calculation/rounding) .
  • Key design issues: RMU/center projects often qualify for parking reductions (up to 25–50% near major transit stops) under § 23.719.080 if within transit proximity; also design review will require active ground floor frontages and pedestrian connectivity to bike/ride facilities .

CMU / GC (Commercial Mixed‑Use / General Commercial) — retail and service centers

  • Purpose & where it applies: commercial districts for shopping, services, restaurants; CMU targets mixed‑use centers; GC is general commercial (Table 23.301‑1) .
  • Typical permitted uses: retail, restaurants, personal services, offices. Parking minimums depend on the use type (e.g., retail and restaurant have per‑1,000‑sf ratios in Table 23.719‑1) .
  • Loading: nonresidential uses follow the loading space sizing and apron rules in § 23.719.150 (industrial loading larger; nonindustrial minimums stated) and loading cannot project into public streets or required setbacks .
  • Key design notes: parking lot landscaping, lighting, and screening rules apply (see the city’s Landscaping and Screening and Chapter 23.716) and design review is commonly required for commercial projects .

M‑1 (Light Industrial / Manufacturing)

  • Purpose & where it applies: light industrial/manufacturing areas (Table 23.301‑1) where goods production, distribution, and freight activities occur .
  • Typical permitted uses: light manufacturing, warehouses, distribution, accessory offices.
  • Parking & loading: industrial uses have higher or differently sized loading requirements — off‑street loading spaces in industrial areas must be at least 60 ft long × 12 ft wide with 15 ft vertical clearance and a 60‑ft maneuvering apron (see § 23.719.150 for the industrial loading standard) . Vehicle parking ratios for industrial‑use floor area appear in Table 23.719‑1 (use the closest matching category when a specific item is omitted) .

Quick reference table — most decision‑relevant parking rules

Topic Rule (plain) Code reference
Vehicle minimums by use Use‑by‑use minimums are in Table 23.719‑1; where multiple ratios apply the higher applies (round to whole spaces) § 23.719.070, Table 23.719‑1
Residential (single‑family) parking Typical required: 2 spaces/unit for single‑family; ADU rules special (see ADU paragraph below) § 23.719.130; Table 23.719‑1
Parking stall size Standard stall: 8.5 ft × 18 ft; minimums for stalls and driveway widths stated in § 23.719.060 and § 23.719.130 § 23.719.060 / § 23.719.130
Bicycle parking Short‑ and long‑term bike parking standards, dimensions, surfacing and exemptions are in § 23.719.110 § 23.719.110
Off‑street loading Industrial: 60'×12' with 60' apron / Non‑industrial: 30'×12' with 30' apron; same‑lot location required § 23.719.150
EV readiness City enforces CALGreen EV‑ready requirements for new construction; EV spots count as standard spaces § 23.719.160; see California Building Standards Code
Reductions / waivers Director may waive minimums via parking district; reductions for transit proximity, extra secure bike parking, shower/locker, or landscaping conversion (caps apply) § 23.719.080

Practical guidance / interpretation tips

  • Use Table 23.719‑1 to determine your base vehicle count, then apply the calculation rules in § 23.719.040 (rounding) and any allowed reductions in § 23.719.080 (transit proximity, additional secure bike parking, etc.) .
  • For mixed‑use buildings, compute parking for each use separately and add them (including loading obligations) — the code explicitly sums required loading spaces where multiple uses are on one parcel (§ 23.719.150) .
  • Residential front‑yard parking is limited: required parking normally must be inside an enclosed garage/carport and may not be in the required front/street‑side setback unless permitted by § 23.719.130; driveways used for excess parking must meet durable/permeable surfacing and impervious coverage limits .
  • Bicycle parking details (rack type, dimensions, clearances, surfacing) must be included on site plans; exemptions exist (temporary uses, agriculture, mini‑storage, home occupations) per § 23.719.110 .
  • For EV infrastructure, the city follows CALGreen and requires EV‑capable wiring/infrastructure for qualifying projects; check § 23.719.160 and Title 24 for technical requirements and verification steps .
  • Design review often catches parking layout and pedestrian access issues — integrate required parking, bike parking, landscaping strips and pedestrian walkways into the design package early to avoid late changes (see Rancho Cordova Design Review and Chapter 23.722 for pedestrian space standards) .

Checklist (for applicants — minimum items city will check)

  • Use Table 23.719‑1 to calculate vehicle parking by each building use and round per § 23.719.040 § 23.719.070 .
  • Show bicycle parking (short‑term and long‑term) with rack type, dimensions, and surfacing per § 23.719.110 .
  • Demonstrate loading areas meet § 23.719.150 size and apron rules and are on the same parcel .
  • Dimension all stalls (minimum 8.5 ft × 18 ft) and drive aisles; show ADA/accessible stalls in compliance with Title 24 (Building Code) § 11B .
  • For residential sites, show garage/carport locations and confirm required parking is not in the front setback unless the specific exception applies (§ 23.719.130) .
  • If seeking reductions (transit, bike provision, parking district waiver), include justification and maps showing distance to transit stops per § 23.719.080 .
  • Include EV‑ready / EV‑capable infrastructure notes consistent with CALGreen and § 23.719.160; coordinate electrical plan with building division and Title 24 requirements .
  • Prepare landscape, lighting, and pedestrian connections for parking areas per Chapters 23.716 and 23.722 (landscaping standards and pedestrian spaces) .

Risks & Ambiguities

Issue Why it matters What to verify
ADU parking and statewide exemptions State law limits local ADU parking requirements and local code references compliance with Government Code rules (e.g., one space per unit/bedroom and several exemptions). Conflicts between local code and state ADU rules can cause processing delays Verify ADU parking guidance and exceptions with Planning; Rancho Cordova references state ADU rules — confirm which ADU standards apply to your parcel (see RCMC notes and state ADU guidance). Not found in retrieved materials: explicit local ADU parking ordinance text — Verify with jurisdiction
Shared parking / mixed‑use credit Mixed‑use projects may count shared or adjacent parking differently; Table 23.719‑1 gives minimums but shared‑use credit and timing can change required stalls Where shared parking or off‑site parking is proposed, confirm the director’s interpretation and any required legal instrument (parking agreement) per § 23.719.030 and § 23.719.080
Transit proximity reductions The code allows 25–50% reductions if within 1/2 or 1/4 mile of major transit stops, but “major transit stop” must be interpreted on a site‑by‑site basis Verify the city’s transit stop map and the director’s determination when claiming a transit reduction (§ 23.719.080)
Bicycle parking detail / exemptions Bicycle rules are prescriptive (rack types, dimensions). Failure to show required long‑term bike parking can block approval Provide exact bike rack specs and surfacing on plans; check exemptions in § 23.719.110
Loading size for unique uses Some special or large uses require a parking/loading study or larger loading — industrial rules are different from commercial Confirm required loading size (industrial vs nonindustrial) and whether parking study is required per § 23.719.150

Plain‑English summary

Rancho Cordova requires a specific number of off‑street parking spaces for almost every type of use (listed in Table 23.719‑1), enforces standard stall sizes and driveway rules for residences, requires bicycle parking and on‑site loading spaces where applicable, and permits reductions for projects that are transit‑oriented or provide extra bike facilities. Plan parking counts from Table 23.719‑1, follow the dimensional rules in § 23.719.060/130, and ask planning staff to confirm any transit, shared parking, or ADU exceptions early in design .


Source References

  • RCMC Chapter 23.719, Parking and Loading (purpose, applicability, permit requirements, calculations, vehicle ratios, design standards, bicycle parking, loading, EV readiness): § 23.719.010 – § 23.719.170 .
  • Table 23.719‑1 (Required Minimum Vehicle Ratios) and related notes: Table 23.719‑1 and § 23.719.070 (vehicle ratios) .
  • Residential off‑street parking standards and private residence rules: § 23.719.130 and § 23.719.060 (dimensions, driveways) .
  • Reductions and exceptions to minimum parking requirements (transit, bicycle, parking district): § 23.719.080 .
  • Bicycle parking requirements: § 23.719.110 (rack types, dimensions, surfacing, exemptions) .
  • Off‑street loading standards (sizes, location, alley access): § 23.719.150 .
  • EV parking / CALGreen integration: § 23.719.160 and the California Green Building Standards Code (CALGreen) / Title 24 references .
  • Zoning district list and table: Table 23.301‑1 (Zoning Districts) and zoning map rules: § 23.301.020 – § 23.301.030 .
  • Objective multifamily design standards affecting parking location and frontage: Chapter 23.707 (Objective Design Standards for Multifamily) .
  • Rancho Cordova ADU/State ADU guidance referenced by the code (state law interactions): ADU handbook and references to Government Code and local implementation notes (state/ADU references in the materials) .
  • Landscaping and pedestrian space standards that affect parking layout: Chapters 23.716 and 23.722 .

Sources

Retrieved passages

  • Rancho Cordova Zoning Code (section requires) High relevance
  • Rancho Cordova Zoning Code (§ 1) High relevance
  • Rancho Cordova Zoning Code (§ 1) High relevance
  • CBC § 1 (§ 1) High relevance
  • Rancho Cordova Zoning Code (§ 1) High relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • Rancho Cordova Zoning Code (Chapter 23.719) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • CBC § 719 (section of) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • Rancho Cordova Zoning Code (§ 66314) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) Medium relevance
  • Rancho Cordova Zoning Code (Title 23.) Medium relevance
  • Rancho Cordova Zoning Code (Chapter 23.101.) Medium relevance
  • Rancho Cordova Zoning Code (§ 3) Medium relevance
  • CBC § 66314 (§ 66314) Medium relevance
  • Rancho Cordova Zoning Code (§ 1) High relevance
  • Rancho Cordova Zoning Code (§ 66322) Medium relevance
  • Rancho Cordova Zoning Code (§ 23.313.040.) Medium relevance
  • Rancho Cordova Zoning Code (Section 18541) Medium relevance

Cited sections

Frequently asked questions

What parking ratio applies to a new retail store in Rancho Cordova?

Retail and restaurant uses use the values listed in Table 23.719‑1; calculate required vehicle parking from that table, round per § 23.719.040, and show bicycle parking per § 23.719.110. For mixed‑use projects add the requirements for each use on the parcel .

Can I count on‑street spaces for my project’s parking requirement?

On‑street credit is limited. The code allows certain on‑street credit in specific cases (see table notes) but required off‑street parking stays the baseline — always confirm any on‑street credit with the director and show any credit calculation on the plans; see Table 23.719‑1 notes and § 23.719.030 for permit review implications .

How big must each parking stall be?

Standard parking stalls shall be at least 8.5 ft × 18 ft and aisles and other layout dimensions are set in § 23.719.060; accessible stalls and other features must comply with Title 24/ADA requirements (coordinate with building division) .

What are the bicycle parking rules I must meet?

Bicycle parking must meet the standards in § 23.719.110: type (short‑ vs long‑term), rack anchoring and security, dimensions (e.g., 1.5 ft × 6 ft per single bicycle space, 5 ft access aisles), surfacing, and exemptions for certain uses; show bike racks and surfacing on the site plan .

Does Rancho Cordova require EV charging infrastructure in parking?

Yes — the city requires EV‑capable infrastructure consistent with CALGreen and verifies installation during plan review; see § 23.719.160 for the city’s approach and coordinate with the building code requirements in Title 24 (CALGreen) for technical specs .

Can I reduce vehicle parking if my project is near transit?

Yes. § 23.719.080 allows parking reductions for projects within 1/2 mile (25% reduction) or 1/4 mile (50% reduction) of a major transit stop, subject to director approval and limits — verify the qualifying transit stop designation with Planning staff and include the justification in your application .

Are loading spaces treated differently for industrial vs commercial uses?

Yes. Industrial off‑street loading spaces must meet the larger industrial dimensions (minimum 60' × 12' with 60' maneuvering apron and 15' vertical clearance), while nonindustrial loading is typically 30' × 12' with a 30' apron (§ 23.719.150) .

How does parking work for accessory dwelling units (ADUs)?

Rancho Cordova’s code references state ADU law: local requirements cannot exceed one space per ADU or per bedroom (whichever is less) and certain ADUs are exempt (e.g., within 1/2 mile of transit) — consult the ADU rules and the city’s implementing notes and confirm with Planning because the state law controls where conflicts appear .

Do I need a separate permit to reconfigure an existing parking lot?

Significant modifications or expansions triggering a change in number/configuration require a building permit and/or zoning certification; minor maintenance and restriping are exempt (see § 23.719.030 for permit categories and exemptions) .

Where do I find the official list of zoning districts and whether my parcel is in a mixed‑use or industrial zone?

Consult Table 23.301‑1 and the city zoning map; the table lists base zoning symbols (RMU, CMU, GC, M‑1, etc.) and the map is the legal zoning boundary (see § 23.301.020–.030) — verify any boundary uncertainty with the director .

More in Rancho Cordova code

Ask about any Rancho Cordova property

Get a cited, plain-English answer on Rancho Cordova zoning, setbacks, FAR, ADUs and permits — for any address.

Start Free Trial

More Rancho Cordova zoning topics