-
Up to 2 units per parcel, and each unit may be at least 800 square feet.
§ 18.101.110 · code text
The standards set forth in this chapter shall not preclude the construction of up two housing development units per parcel and shall not preclude each housing development unit from being at least 800 square feet in floor area.
-
No more than 15 feet high.
Applies: The part of a unit between the 4-foot setback line and the edge of the rear, side or street side yard.
§ 18.101.110 · code text
If a housing development unit is located in the side or rear yard otherwise established for the zoning district by Chapter 18.84 of this title, the maximum height of the portion of a housing development unit located between the four-foot setback line established by this chapter and the limit of the rear, side, or street side yard area established by Chapter 18.84 of this title is 15 feet, as measured from the lowest grade adjacent to the structure to the highest ridge or top of the structure, including parapet.
-
Upper-story floor area is limited to 40% of the first-floor area.
Applies: Applies to housing development units.
§ 18.101.110 · code text
The floor area of the upper stories of housing development units shall be limited to 40 percent of the floor area on the first floor.
-
At least 20 feet between the unit's upper stories and the neighbor's upper stories.
Applies: Applies when both the unit and the neighboring structure are 2 or more stories.
§ 18.101.110 · code text
Where both the housing development unit and the structure on the adjacent property is two or more stories, a minimum separation of 20 feet shall be provided between the upper stories of the housing development unit and the upper stories of the structure on the adjacent property.
-
At least 17 feet between the unit's upper stories and the neighbor's structure.
Applies: Applies when the unit is 2 or more stories and the neighboring structure is 1 story.
§ 18.101.110 · code text
Where only the housing development unit is two or more stories and the structure on the adjacent parcel is one story, a minimum separation of 17 feet shall be provided between the upper stories of the housing development unit and structure on the adjacent property.
-
Units must be at least 6 feet from accessory structures.
Applies: Accessory structures on the same parcel, the other split parcel or adjacent parcels. Closer is allowed under listed conditions.
§ 18.101.110 · code text
Housing development units shall be separated from accessory structures on the same parcel, parcels resulting from an urban lot split, or adjacent parcels by a minimum of six feet, except that the distance between a main structure and an accessory structure shall be allowed to be closer than six feet if all of the following conditions are met:
-
Roof slope of at least 3:12, gable, hip or cross gable; no mansard roofs.
Applies: Applies to new structures.
§ 18.101.110 · code text
New structures shall provide a roof sloped to a minimum of 3:12 inches.
-
Eaves and gable rakes must project at least 12 inches from the wall.
Applies: Applies to housing development units.
§ 18.101.110 · code text
These overhanging elements shall project a minimum of 12 inches from the face of the adjacent building wall.
-
At least 25% of the roof area must have hip, gable or shed dormers.
Applies: Applies to housing development units.
§ 18.101.110 · code text
A minimum of 25 percent of roof area shall be articulated with any combination of hip, gable, or shed dormers.
-
Use 1 privacy method: sill at least 60 inches up, glazing offset over 15 feet from neighbors', or obscured glass.
Applies: Upper-story windows closer than 25 feet to and facing an existing home on an adjacent property.
§ 18.101.110 · code text
Upper story windows located closer than 25 feet from and facing an existing primary residence on an adjacent property shall be located to maximize privacy for adjacent properties by using at least one of the following techniques:
-
At least 30 feet of frontage on the public right-of-way, with direct vehicle access.
Applies: Applies to each new parcel. Flag lots are excepted.
§ 18.101.100 · code text
Each parcel shall provide for direct vehicular access to and have a minimum frontage of 30 feet on the public right-of-way, except for flag lots, where the frontage shall be the width needed to meet access standards as specified in this chapter.
-
Each parcel must be at least 30 feet wide.
Applies: Applies to each new parcel.
§ 18.101.100 · code text
Parcels shall have a minimum width of 30 feet. Width shall be determined in accordance with the definition in Chapter 18.08 of this title.
-
Each parcel must be at least 40 feet deep.
Applies: Applies to each new parcel.
§ 18.101.100 · code text
Parcels shall have a minimum depth of 40 feet. Depth shall be determined in accordance with the definition in Chapter 18.08 of this title.