Skip to content

Oxnard · Zoning · R-2

Oxnard R-2 zoning: height, setbacks and lot size

In Oxnard's R-2 zone, buildings can be up to 25 ft (2 stories) tall and the front setback is 25% of lot depth, minimum 25 ft, maximum 60 ft (Oxnard code, read October 2026).

Key points

  • Maximum building height: 25 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 25% of lot depth, minimum 25 ft, maximum 60 ft
  • Minimum side setback: 10% of lot width, minimum 3 ft, maximum 5 ft
  • Maximum density: 1 unit per 3,500 sq. ft.

R-2 is a zoning district in Oxnard. Every value below was read from the Oxnard Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
25 ft
§ 16-23 · code text
Table row “Height permitted”, column “R-2”: Two stories up to 25 ft.
Maximum number of stories
2 stories
§ 16-23 · code text
Table row “Height permitted”, column “R-2”: Two stories up to 25 ft.
Minimum front setback
25% of lot depth, minimum 25 ft, maximum 60 ft
§ 16-23 · code text
Table row “Front yard setback”, column “R-2”: 25% of the depth of the lot, not less than 25 ft. or more than 60 ft. See Section 16-24 for additional requirements
Minimum side setback
10% of lot width, minimum 3 ft, maximum 5 ft
§ 16-23 · code text
Table row “Interior yard side yard setback”, column “R-2”: 10% of the width of the lot, but not less than 3 ft., and need not exceed 5 ft.
Maximum density
1 unit per 3,500 sq. ft.
§ 16-23 · code text
Table row “Minimum lot area/density”, column “R-2”: 3,500 sq. ft. of lot area for each dwelling unit. See Section 16-24 for additional requirements

Uses in R-2

Uses the code's use tables allow in R-2, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general rear setback, lot size, lot coverage, FAR limit for R-2 in the zoning tables we read. The code may still set one elsewhere — check the Oxnard Municipal Code.

Other Oxnard zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Oxnard's R-2 zone?

25 ft — Oxnard Municipal Code § 16-23.

What is the maximum number of stories in Oxnard's R-2 zone?

2 stories — Oxnard Municipal Code § 16-23.

What is the minimum front setback in Oxnard's R-2 zone?

25% of lot depth, minimum 25 ft, maximum 60 ft — Oxnard Municipal Code § 16-23.

What is the minimum side setback in Oxnard's R-2 zone?

10% of lot width, minimum 3 ft, maximum 5 ft — Oxnard Municipal Code § 16-23.

What is the maximum density in Oxnard's R-2 zone?

1 unit per 3,500 sq. ft. — Oxnard Municipal Code § 16-23.

General information, not legal advice.

Ask about an Oxnard property in R-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Oxnard