Skip to content

Oakland · Zoning · D-CO-3

Oakland D-CO-3 zoning: height, setbacks and lot size

In Oakland's D-CO-3 zone, the front setback is 10 ft and the minimum lot size is 5,000 sf (Oakland code, read October 2026).

Key points

  • Minimum front setback: 10 ft
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft (Nonresidential Facilities; Residential Facilities: N/A)
  • Minimum lot size: 5,000 sf
  • Maximum floor area ratio (FAR): 6.0 (Nonresidential Facilities)

D-CO-3 is a zoning district in Oakland. Every value below was read from the Oakland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in D-CO-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Minimum front setback
10 ft
§ 17.101H.050 · code text
Table row “Minimum front”, column “D-CO-3”: 10 ft.
Minimum side setback
0 ft
§ 17.101H.050 · code text
Table row “Minimum interior side”, column “D-CO-3”: 0 ft.
Minimum rear setback
0 ft
Applies: Nonresidential Facilities; Residential Facilities: N/A
§ 17.101H.050 · code text
Table row “Rear (Nonresidential Facilities)”, column “D-CO-3”: 0 ft.
Minimum lot size
5,000 sf
§ 17.101H.050 · code text
Table row “Lot area”, column “D-CO-3”: 5,000 sf.
Maximum floor area ratio (FAR)
6.0
Applies: Nonresidential Facilities
§ 17.101H.050 · code text
Table row “Maximum Nonresidential Floor Area Ratio (FAR)”, column “D-CO-3”: 6.0

When a different number applies

The code sets other values for particular lots, buildings or locations in D-CO-3:

  • Maximum building height: 100 ft above mean sea level — buildings in the D-CO areas between Doolittle Drive, Swan Way, Pardee Drive, and Hegenberger Road; the FAA Part 77 height surfaces also apply § 17.101H.050

Not on this page

We did not find a general height, stories, lot coverage, density limit for D-CO-3 in the zoning tables we read. The code may still set one elsewhere — check the Oakland Municipal Code.

Other Oakland zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the minimum front setback in Oakland's D-CO-3 zone?

10 ft — Oakland Municipal Code § 17.101H.050.

What is the minimum side setback in Oakland's D-CO-3 zone?

0 ft — Oakland Municipal Code § 17.101H.050.

What is the minimum rear setback in Oakland's D-CO-3 zone?

0 ft (nonresidential Facilities; Residential Facilities: N/A) — Oakland Municipal Code § 17.101H.050.

What is the minimum lot size in Oakland's D-CO-3 zone?

5,000 sf — Oakland Municipal Code § 17.101H.050.

What is the maximum floor area ratio (far) in Oakland's D-CO-3 zone?

6.0 (nonresidential Facilities) — Oakland Municipal Code § 17.101H.050.

General information, not legal advice.

Ask about an Oakland property in D-CO-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Oakland