Skip to content

Morgan Hill · Zoning · SRL-B

Morgan Hill SRL-B zoning: height, setbacks and lot size

In Morgan Hill's SRL-B zone, buildings can be up to 35 ft tall, the front setback is 20 ft and the minimum lot size is 1 acre (Morgan Hill code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 20 ft
  • Minimum side setback: 15 ft
  • Minimum rear setback: 15 ft
  • Minimum lot size: 1 acre
  • Maximum lot coverage: 50%

SRL-B is a zoning district in Morgan Hill. Every value below was read from the Morgan Hill Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in SRL-B

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 18.28.030 · code text
Table row “Height, Maximum”, column “SRL-B”: 35 ft.
Minimum front setback
20 ft
§ 18.28.030 · code text
Table row “Front”, column “SRL-B”: 20 ft.
Minimum side setback
15 ft
§ 18.28.030 · code text
Table row “Interior Side”, column “SRL-B”: 15 ft.
Minimum rear setback
15 ft
§ 18.28.030 · code text
Table row “Rear”, column “SRL-B”: 15 ft.
Minimum lot size
1 acre
§ 18.28.030 · code text
Table row “Lot Area, Minimum”, column “SRL-B”: 1 acre
Maximum lot coverage
50%
§ 18.28.030 · code text
Table row “Building Coverage, Maximum”, column “SRL-B”: 50%

Uses in SRL-B

Uses the code's use tables allow in SRL-B, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, FAR, density limit for SRL-B in the zoning tables we read. The code may still set one elsewhere — check the Morgan Hill Municipal Code.

Other Morgan Hill zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Morgan Hill's SRL-B zone?

35 ft — Morgan Hill Municipal Code § 18.28.030.

What is the minimum front setback in Morgan Hill's SRL-B zone?

20 ft — Morgan Hill Municipal Code § 18.28.030.

What is the minimum side setback in Morgan Hill's SRL-B zone?

15 ft — Morgan Hill Municipal Code § 18.28.030.

What is the minimum rear setback in Morgan Hill's SRL-B zone?

15 ft — Morgan Hill Municipal Code § 18.28.030.

What is the minimum lot size in Morgan Hill's SRL-B zone?

1 acre — Morgan Hill Municipal Code § 18.28.030.

General information, not legal advice.

Ask about a Morgan Hill property in SRL-B

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Morgan Hill