Local zoning · McFarland

McFarland — Design Review

Design Review under the McFarland local zoning and planning code, with the controlling citations.

Last reviewed: July 6, 2026

Overview

In McFarland, “design review” is implemented primarily through the city’s Site Development Plan review under Title 17, alongside Precise Development (P-D) plan approvals and, where mapped, the D Architectural Design overlay. Most multifamily, commercial, and industrial projects must secure Site Development Plan approval to verify compatibility with surrounding uses and conformance with citywide development standards. § 17.134.010, § 17.134.050

Bottom line: If you’re building or substantially improving multifamily, commercial, or industrial development in McFarland, expect Site Development Plan review focused on architecture, site layout, screening, lighting, landscaping, parking, and neighborhood compatibility. § 17.134.010, § 17.134.020(J)

What triggers design review (Site Development Plan)

  • Required before establishing a permitted use, commencing permitted development, or issuing a building or grading permit for development subject to Chapter 17.134. The Planning Commission is the reviewing authority. § 17.134.050
  • No separate Site Development Plan is required if the use is already subject to a Conditional Use Permit (CUP). The Planning Director may waive formal review for minor additions of 400 sq ft or less or for a change to a less intensive use. § 17.134.070
  • A landscape plan is separately reviewed when a discretionary or ministerial approval is required for the use; conceptual landscaping accompanies the primary application, with detailed plans approved before grading or building permits. § 17.146.070(A)

What the city evaluates (key design standards)

  • Architectural compatibility: proposed building design must be compatible with the surrounding neighborhood. § 17.134.020(J)
  • Privacy protection near single-family: when new buildings over one story are next to single-family zones, upper windows must be opaque/translucent or otherwise screened as approved. § 17.134.020(G)
  • Lighting: on-site lighting may not directly or indirectly illuminate adjacent properties or the frontage street. § 17.134.020(H)
  • Trash/service: trash enclosures must be screened and method/location approved; multifamily refuse enclosures must be landscaped and accessible for collection. § 17.134.020(I) and multifamily refuse standards § 17.134.020(F)(9)
  • Screening and edge conditions:
    • Rooftop equipment should be screened as an integral architectural element. § 17.134.020(L)(1)
    • Non-enclosed operations across from residential require a masonry wall and frontage landscaping; no storage above fence height. § 17.134.020(L)(2)
    • In the C-O, C-1, and C-2 districts, most business activities must occur inside an enclosed structure (exceptions: parking/loading, gas stations, outdoor dining, nurseries/garden shops). § 17.134.020(L)(3)
    • When adjacent to residential zoning, a 6 ft solid masonry wall in a 5 ft planter with trees at 20 ft spacing is required (reduced to 4 ft in the front setback). Wall design/materials require approval. § 17.134.020(K)
    • Fence/wall materials must be compatible; chain link or metal fencing is prohibited except in M-1, M-2, M-3. § 17.134.020(N)
  • Parking/landscaping/signs: comply with Chapters 17.144 (parking), 17.146 (landscaping) and 17.142 (signs) — including parking-lot landscaping and screening near residential, and submittal of a parking lot plan under § 17.144.110. § 17.134.020(O)–(Q); § 17.134.020(H)(1)–(S) excerpts; § 17.146.070(A)

Application contents (what you must submit)

A Site Development Plan application must include, at minimum: applicant/owner information; APNs; legal description; a scaled plan showing topography and grading; existing/proposed buildings; vehicular circulation and parking; [Fire] access approvals; proposed landscaping per Chapter 17.146; building elevations; phasing/schedule; and details for frontage and utility improvements. § 17.134.060(A)–(H)

Related design review pathways

  • Precise Development (P-D) zoning: Before any permit in a P-D zone, a P-D plan must be approved by the Planning Commission. The plan is highly detailed (plot plan, grading, building locations/uses, landscaping, parking layout, signs, walls/fences, circulation, and project statistics like height, coverage, open space). § 17.132.030, § 17.132.040(A)–(B)
  • D Architectural Design overlay: McFarland maps a combined D zone (“architectural design zone”), which applies additional architectural regulations wherever combined with a base zone. Specific standards are contained in § 17.108.020 (Architectural standards). § 17.108.010–.020
  • Mixed-use CRMU: FAR increases may be considered when a project provides “a high level of architectural design” or other public amenities; signs and parking must still follow the base regulations. § 17.78.050(A)–(D), § 17.78.150, § 17.78.160

District-by-district design review scope

The development standards and Site Development Plan requirement explicitly apply to projects in these districts: R-2, R-3, RP, C-O, C-1, C-2, M-1, M-2, M-3, and P-D. § 17.134.010

R-2 (Two-Family Residential)

  • Purpose/uses: Two-family dwellings and any use permitted in R-1; home occupations. § 17.20.020(A)–(C)
  • Key dimensional standards: Max height two-and-one-half stories/35 ft; front yard 25 ft (with averaging rule); side yard 5 ft (10 ft street side on corners); rear yard 5 ft; min lot area 6,000 sq ft, min 3,000 sq ft per dwelling; max lot coverage 50%. § 17.20.030–.070
  • Where Site Development Plan review applies: Multifamily-like site planning and any project subject to Chapter 17.134 within mapped R-2 areas. § 17.134.010, § 17.134.050

R-3 (Limited Multiple-Family Residential)

  • Purpose/uses: R-1/R-2 uses plus three- and four-family dwellings, bungalow courts. § 17.24.020(A)–(C)
  • Key dimensional standards: Max height two-and-one-half stories/35 ft; front yard 15 ft (with averaging rule); side yard 5 ft (10 ft corner); rear yard standard continues in chapter. § 17.24.030–.050; see chapter for rear yard § 17.24.060.
  • Applicability: All R-3 multifamily developments are within Chapter 17.134’s scope. § 17.134.010

RP (Residential Professional)

  • Purpose/uses: Not found in retrieved materials.
  • Key dimensional standards: Not found in retrieved materials.
  • Applicability: Listed in Chapter 17.134; confirm base standards before filing. § 17.134.010; Verify with the jurisdiction.

C-O (Professional Office)

  • Purpose/uses: Broad professional and administrative offices plus selected retail/services (e.g., medical offices, labs, pharmacies with clinics). § 17.72.020(A)–(B)
  • Key dimensional standards: No side yard; rear yard 20 ft (may be reduced by variance with Fire approval); specific front setback measured from highway centerlines in § 17.72.050; minimum lot area and internal distances as stated in chapter. § 17.72.050–.090; § 17.72.100 (parking equal to office floor area)
  • Applicability: Site Development Plan required for C-O projects under Chapter 17.134; most operations must be indoors. § 17.134.010; § 17.134.020(L)(3)

C-1 (Neighborhood Commercial)

  • Purpose/uses: Any C-O use plus listed neighborhood commercial uses (e.g., certain indoor recreation). § 17.76.020(A)–(1)
  • Key dimensional standards: Chapter includes distance-between-buildings; area requirements reference are included; confirm current front/side/rear setbacks for your parcel. § 17.76.070–.080; Verify with the jurisdiction.
  • Applicability: Enclosed-operations rule applies; Site Development Plan review under Chapter 17.134. § 17.134.020(L)(3); § 17.134.050

C-2 (Commercial)

  • Purpose/uses: Any C-O/C-1 use plus a wide range of retail, entertainment, lodging, and automobile-oriented uses (e.g., theaters, hotels, auto sales). § 17.80.020(A)–(B)(1)–(3)
  • Key dimensional standards: Minimum lot sizes and residential components reference R-4 where applicable; verify current yard/height standards for your site. § 17.76.070 (cross-reference), and C-2 chapter; Verify with the jurisdiction.
  • Applicability: Subject to Chapter 17.134 design standards and enclosed-operations rule. § 17.134.010; § 17.134.020(L)(3)

M-1 (Limited Manufacturing)

  • Purpose/uses: Manufacturing/warehousing and certain commercial uses; some outdoor storage uses allowed if fully enclosed by a 6 ft masonry wall and screened. § 17.84.020(B), (B)(6)
  • Key dimensional standards: Max height two stories/35 ft; front/side/rear yard standards as stated. § 17.84.030–.070
  • Applicability: Chapter 17.134 applies; chain link may be allowed in M-1 for fencing. § 17.134.010; § 17.134.020(N)

M-2 (Light Manufacturing)

  • Purpose/uses and key standards: Not found in retrieved materials.
  • Applicability: Listed in Chapter 17.134; confirm base standards prior to submittal. § 17.134.010; Verify with the jurisdiction.

M-3 (General Manufacturing)

  • Purpose/uses and key standards: Not found in retrieved materials.
  • Applicability: Listed in Chapter 17.134; confirm base standards prior to submittal. § 17.134.010; Verify with the jurisdiction.

P-D (Precise Development)

  • Purpose/uses: Custom zoning tied to a Precise Development Plan; uses reference a base zone. § 17.132.020
  • Key dimensional standards: Set by the adopted P-D plan; no construction or grading until the plan is approved. § 17.132.030–.040(B)
  • Applicability: The P-D plan is the controlling “design program,” reviewed by the Planning Commission. § 17.132.030–.040(A)

Decision-relevant standards and triggers

Topic Standard / Trigger Code Reference
When Site Development Plan is required Before establishing a permitted use or issuing building/grading permits for covered districts § 17.134.050
Waiver threshold Planning Director may waive for additions ≤400 sq ft or change to less intensive use § 17.134.070
If a CUP is required No separate Site Development Plan is required § 17.134.070
Architecture Must be compatible with surrounding neighborhood § 17.134.020(J)
Screening next to residential 6 ft masonry wall in 5 ft planter with trees at 20 ft spacing (4 ft within front setback) § 17.134.020(K)
Enclosed operations (C-O/C-1/C-2) All business/services indoors (listed exceptions) § 17.134.020(L)(3)
Parking lot plan submittal Required per § 17.144.110; includes lot landscaping/shade rules § 17.134.020(H)(1)–(S); § 17.144.110
Landscape plan approval Conceptual with main app; detailed plan approved prior to permits § 17.146.070(A)

Checklist

  • Confirm your site’s base zoning and any overlays; check whether your project falls in R-2, R-3, RP, C-O, C-1, C-2, M-1, M-2, M-3, or P-D. § 17.134.010
  • Determine if Site Development Plan review is required or waived (≤400 sq ft addition or less intensive change of use) or superseded by a CUP. § 17.134.050, § 17.134.070
  • Prepare a complete submittal: scaled site plan; grading; existing/proposed buildings; circulation and parking; Fire access; landscaping per Chapter 17.146; building elevations; phasing/schedule; public improvements (curb, gutter, sidewalks; utilities). § 17.134.060(A)–(H)
  • Design for compatibility: architecture, privacy screens/upper windows, lighting cutoffs, screened trash, rooftop equipment screening, and residential edge treatments. § 17.134.020(G)–(N)
  • Verify signage conforms to Chapter 17.142 and that commercial operations are enclosed where required. § 17.134.020(L)(3), (Q)
  • If mapped in P-D, assemble the detailed P-D plan for Planning Commission approval. § 17.132.030–.040
  • If mapped in the D Architectural Design overlay, confirm applicable architectural standards. § 17.108.010–.020; Verify with the jurisdiction.

Risks & Ambiguities

Issue Why it matters What to verify
CUP vs. Site Development Plan If a CUP is required, separate Site Development Plan may not be needed Confirm whether your use requires a CUP and whether review will be consolidated. § 17.134.070
“Compatible architecture” is subjective Design changes can be requested late if compatibility is questioned Meet early with staff; bring elevations/materials; reference nearby precedents. § 17.134.020(J)
Minor addition waiver is discretionary The Planning Director decides whether to waive formal review Pre-screen to confirm if your ≤400 sq ft addition qualifies. § 17.134.070
Enclosed-operations rule in commercial zones Outdoor operations may trigger redesign or screening Scope of allowed outdoor activity in C-O/C-1/C-2; exceptions. § 17.134.020(L)(3)
Fence/wall material limits Chain link prohibited in most zones If industrial, confirm if M-1/M-2/M-3 allowances apply. § 17.134.020(N)
D overlay standards Additional architectural requirements may apply Whether your parcel carries the D overlay and its standards. § 17.108.010–.020; Verify with the jurisdiction.

Plain-English Summary

McFarland runs design review through a Site Development Plan process that checks your project’s look and layout against city rules. For most multifamily, commercial, and industrial sites, you submit a complete plan showing buildings, circulation, parking, landscaping, and elevations; the Planning Commission reviews it for neighborhood fit, privacy, screening, and signage. Small additions may get a waiver, and if you’re in a Precise Development zone, your detailed P-D plan is the controlling design document. § 17.134.010, § 17.134.050–.070; § 17.132.030–.040

Source References

  • McFarland Municipal Code: Development Standards, Site Development Plan review and standards — § 17.134.010, § 17.134.020, § 17.134.050–.070, § 17.134.080
  • Landscaping plan approval — § 17.146.070(A)
  • Precise Development zoning and plan content — § 17.132.020–.040
  • D Architectural Design overlay — § 17.108.010–.020
  • Selected base district references: R-2 § 17.20.020–.080; R-3 § 17.24.020–.060; C-O § 17.72.020, § 17.72.060–.100; C-1 § 17.76.020, § 17.76.070–.080; C-2 § 17.80.020; M-1 § 17.84.020–.090; CRMU § 17.78.050, § 17.78.150–.160

Sources

Retrieved passages

  • McFarland Zoning Code (§ 30.00) High relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • McFarland Zoning Code (Section 17.36.140.) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • CBC § 1 (section apply.) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • McFarland Zoning Code (Chapter 17.146) Medium relevance
  • McFarland Zoning Code (Chapter 17.146) Medium relevance
  • McFarland Zoning Code (Section 17.152.010) Medium relevance
  • McFarland Zoning Code (§ 34.11) Medium relevance
  • McFarland Zoning Code (§ 34.09) Medium relevance
  • CBC § 1 (§ 1) Medium relevance
  • McFarland Zoning Code (chapter relating) Medium relevance
  • McFarland Zoning Code (§ 32.17) Medium relevance
  • McFarland Zoning Code (chapter for) Medium relevance
  • McFarland Zoning Code (§ 5.04) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance
  • McFarland Zoning Code (§ 30.03) Medium relevance
  • McFarland Zoning Code (§ 2) Medium relevance
  • McFarland Zoning Code (§ 1) Medium relevance

Cited sections

Frequently asked questions

Do I need Site Development Plan review for my project in McFarland?

If you’re developing or substantially improving a multifamily, commercial, or industrial project, yes—Site Development Plan approval is required before permits issue. If your use requires a Conditional Use Permit (CUP), a separate Site Development Plan is not required. § 17.134.050, § 17.134.070

Can small building additions skip design review?

Possibly. The Planning Director may waive formal Site Development Plan review for minor structural additions of 400 square feet or less, or when changing to a less intensive use. Always confirm in a pre-application meeting. § 17.134.070

Who approves Site Development Plans?

The Planning Commission reviews and approves Site Development Plans for covered districts. Conditions may address architecture, screening, lighting, and site circulation. § 17.134.050, § 17.134.020

What must my design submittal include?

A scaled site plan, grading, existing/proposed buildings, vehicle circulation and parking, Fire access clearances, proposed landscaping, building elevations, phasing/schedule, and details of public improvements. § 17.134.060(A)–(H)

How does the city evaluate “compatibility”?

Staff and the Commission look at architectural style, privacy (e.g., screening of upper windows near single-family), on-site lighting spillover, trash/recycling screening, equipment screening, and edge treatments (e.g., required walls next to residential). § 17.134.020(G)–(N), (K)

I’m in a Precise Development (P-D) district—what’s different?

You must secure approval of a P-D plan before any grading or building permits. The P-D plan is a detailed design program laying out the site plan, landscaping, signs, walls, circulation, and project statistics; once adopted, it controls your project. § 17.132.030–.040

Will I also need a landscaping approval?

Yes. When a discretionary or ministerial approval is required, you submit a conceptual landscape plan with your main application; a detailed plan is approved by the Planning Department before building or grading permits. § 17.146.070(A)

Are outdoor business activities allowed in commercial zones?

Generally not. In C-O, C-1, and C-2, most operations must be inside an enclosed structure, with limited exceptions (e.g., parking/loading, gas stations, outdoor dining, nurseries). § 17.134.020(L)(3)