Skip to content

Marysville · Zoning · C-1

Marysville C-1 zoning: height, setbacks and lot size

In Marysville's C-1 zone, generally buildings can be up to 35 ft (2.5 stories) tall and the front setback is 5 ft, with the conditions listed below (Marysville code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2.5 stories
  • Minimum front setback: 5 ft (15 ft for a distance of 25 ft from an R district boundary; yard must be landscaped, with no parking or loading)
  • Minimum side setback: None required (5 ft when abutting a residential zone district)
  • Minimum rear setback: None required (5 ft with a 6-foot masonry wall when abutting a residential zone; 12 ft if accessible by a street, alley or parking lot)

C-1 (C-1 zone district) is a zoning district in Marysville. Every value below was read from the Marysville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 18.24.030 · code text
Table row “Maximum building height”, column “Maximum building height”: 2.5 stories, not to exceed 35 feet. Other criteria and exceptions are provided in Section 18.84.080 .
Maximum number of stories
2.5 stories
§ 18.24.030 · code text
Table row “Maximum building height”, column “Maximum building height”: 2.5 stories, not to exceed 35 feet. Other criteria and exceptions are provided in Section 18.84.080 .
Minimum front setback
5 ft
Applies: 15 ft for a distance of 25 ft from an R district boundary; yard must be landscaped, with no parking or loading
§ 18.24.030 · code text
Table row “Minimum yards”, column “Minimum yards”: Front yard: 5 feet, except 15 feet for a distance of 25 feet from an R district boundary. Yard must be landscaped and not used for parking or loading. Upper story may overhang if there is a vertical clearance of 12 feet. Street side yard: Same as front yard, except no side yard adjacent to an alley. Interior side yard: None, except when abutting a residential zone district it is 5 feet. Rear yard: None, except (1) when abutting a residential zone district it is 5 feet and a 6-foot masonry wall shall be constructed along the property line or (2) it is 12 feet if accessible by a street, alley or parking lot. Upper floor may overhang if there is 14 feet of vertical clearance if not located abutting a residential zone district. Levee setback: 10 feet. Other criteria and exceptions are provided in Section 18.84.070 , Yards and fences.
Minimum side setback
None required
Applies: 5 ft when abutting a residential zone district
§ 18.24.030 · code text
Table row “Minimum yards”, column “Minimum yards”: Front yard: 5 feet, except 15 feet for a distance of 25 feet from an R district boundary. Yard must be landscaped and not used for parking or loading. Upper story may overhang if there is a vertical clearance of 12 feet. Street side yard: Same as front yard, except no side yard adjacent to an alley. Interior side yard: None, except when abutting a residential zone district it is 5 feet. Rear yard: None, except (1) when abutting a residential zone district it is 5 feet and a 6-foot masonry wall shall be constructed along the property line or (2) it is 12 feet if accessible by a street, alley or parking lot. Upper floor may overhang if there is 14 feet of vertical clearance if not located abutting a residential zone district. Levee setback: 10 feet. Other criteria and exceptions are provided in Section 18.84.070 , Yards and fences.
Minimum rear setback
None required
Applies: 5 ft with a 6-foot masonry wall when abutting a residential zone; 12 ft if accessible by a street, alley or parking lot
§ 18.24.030 · code text
Table row “Minimum yards”, column “Minimum yards”: Front yard: 5 feet, except 15 feet for a distance of 25 feet from an R district boundary. Yard must be landscaped and not used for parking or loading. Upper story may overhang if there is a vertical clearance of 12 feet. Street side yard: Same as front yard, except no side yard adjacent to an alley. Interior side yard: None, except when abutting a residential zone district it is 5 feet. Rear yard: None, except (1) when abutting a residential zone district it is 5 feet and a 6-foot masonry wall shall be constructed along the property line or (2) it is 12 feet if accessible by a street, alley or parking lot. Upper floor may overhang if there is 14 feet of vertical clearance if not located abutting a residential zone district. Levee setback: 10 feet. Other criteria and exceptions are provided in Section 18.84.070 , Yards and fences.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-1:

  • Minimum front setback: 15 ft — for a distance of 25 feet from an R district boundary § 18.24.030
  • Minimum side setback: 5 ft — when abutting a residential zone district § 18.24.030
  • Minimum rear setback: 5 ft — when abutting a residential zone district; a 6-foot masonry wall shall be constructed along the property line § 18.24.030
  • Minimum rear setback: 12 ft — if accessible by a street, alley or parking lot § 18.24.030

Not on this page

We did not find a general lot size, lot coverage, FAR, density limit for C-1 in the zoning tables we read. The code may still set one elsewhere — check the Marysville Municipal Code.

Other Marysville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Marysville's C-1 zone?

35 ft — Marysville Municipal Code § 18.24.030.

What is the maximum number of stories in Marysville's C-1 zone?

2.5 stories — Marysville Municipal Code § 18.24.030.

What is the minimum front setback in Marysville's C-1 zone?

5 ft (15 ft for a distance of 25 ft from an R district boundary; yard must be landscaped, with no parking or loading) — Marysville Municipal Code § 18.24.030.

What is the minimum side setback in Marysville's C-1 zone?

None required (5 ft when abutting a residential zone district) — Marysville Municipal Code § 18.24.030.

What is the minimum rear setback in Marysville's C-1 zone?

None required (5 ft with a 6-foot masonry wall when abutting a residential zone; 12 ft if accessible by a street, alley or parking lot) — Marysville Municipal Code § 18.24.030.

General information, not legal advice.

Ask about a Marysville property in C-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question