Loma Linda B-P zoning: height, setbacks and lot size

In Loma Linda's B-P zone, generally buildings can be up to 35 ft tall, the front setback is 25 ft and the minimum lot size is 10,000 sq ft, with the conditions listed below (Loma Linda code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 25 ft
  • Minimum lot size: 10,000 sq ft (newly created parcel)
  • Maximum lot coverage: 60%
  • Maximum floor area ratio (FAR): 0.5

B-P (Business Park) is a zoning district in Loma Linda. Every value below was read from the Loma Linda Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in B-P

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
See note 3 below the table in the code.
§ 17.40.040 · code text
Table row “Height – Maximum (feet) (3)”, column “B-P”: 35
Note 3: The maximum height limit may be increased with the approval of a conditional use permit.
Minimum front setback
25 ft
See note 2 below the table in the code.
§ 17.40.040 · code text
Table row “Front”, column “B-P”: 25
Note 2: Decorative masonry walls of six feet in height shall be provided on all property lines which are contiguous to residentially zoned parcels.
Minimum lot size
10,000 sq ft
Applies: newly created parcel
§ 17.40.040 · code text
Table row “Parcel Size – Minimum (sq. ft.)”, column “B-P”: 10,000
Maximum lot coverage
60%
§ 17.40.040 · code text
Table row “Parcel Coverage – Maximum Footprint Coverage (%)”, column “B-P”: 60
Maximum floor area ratio (FAR)
0.5
§ 17.40.040 · code text
Table row “Floor Area Ratio (FAR) – Maximum”, column “B-P”: 0.5

Uses in B-P

Uses the code's use tables allow in B-P, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in B-P:

  • Minimum side setback: 20 ft — abutting a parcel zoned for residential use § 17.40.040
  • Minimum side setback: 5 ft — abutting any other parcel § 17.40.040
  • Minimum rear setback: 20 ft — abutting a parcel zoned for residential use § 17.40.040
  • Minimum rear setback: 10 ft — abutting any other parcel § 17.40.040

Not on this page

We did not find a general stories, side setback, rear setback, density limit for B-P in the zoning tables we read. The code may still set one elsewhere — check the Loma Linda Municipal Code.

Other Loma Linda zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Loma Linda's B-P zone?

35 ft — Loma Linda Municipal Code § 17.40.040.

What is the minimum front setback in Loma Linda's B-P zone?

25 ft — Loma Linda Municipal Code § 17.40.040.

What is the minimum lot size in Loma Linda's B-P zone?

10,000 sq ft (newly created parcel) — Loma Linda Municipal Code § 17.40.040.

What is the maximum lot coverage in Loma Linda's B-P zone?

60% — Loma Linda Municipal Code § 17.40.040.

What is the maximum floor area ratio (far) in Loma Linda's B-P zone?

0.5 — Loma Linda Municipal Code § 17.40.040.

General information, not legal advice.

Ask about a Loma Linda property in B-P

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Loma Linda