King City · Zoning · C-1-TD
King City C-1-TD zoning: height, setbacks and lot size
In King City's C-1-TD zone, generally buildings can be up to 30 ft (2 stories) tall and the front setback is None required, with the conditions listed below (King City code, read October 2026).
Key points
- Maximum building height: 30 ft
- Maximum number of stories: 2 stories
- Minimum front setback: None required (10 ft when the lot or an alley adjacent to it abuts an R district)
- Minimum side setback: None required (10 ft when the lot or an alley adjacent to it abuts an R district)
- Minimum rear setback: None required (10 ft when the lot or an alley adjacent to it abuts an R district)
- Maximum lot coverage: 100% (less required parking and landscaping)
C-1-TD (RETAIL-COMMERCIAL TRANSITION DISTRICT) is a zoning district in King City. Every value below was read from the King City Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in C-1-TD
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 30 ft § 17.23.060 · code textNo building shall be more than two stories, nor more than thirty feet in height. |
|---|---|
| Maximum number of stories | 2 stories § 17.23.060 · code textNo building shall be more than two stories, nor more than thirty feet in height. |
| Minimum front setback | None required Applies: 10 ft when the lot or an alley adjacent to it abuts an R district § 17.23.090 · code textUnless otherwise required in Chapters 17.48 through 17.52, establishing plan lines, or unless optional design standards have been used as set out in Section 17.23.100, there shall be no front, side or rear yard requirement except when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district, in which case the yard requirement shall be ten feet. |
| Minimum side setback | None required Applies: 10 ft when the lot or an alley adjacent to it abuts an R district § 17.23.090 · code textUnless otherwise required in Chapters 17.48 through 17.52, establishing plan lines, or unless optional design standards have been used as set out in Section 17.23.100, there shall be no front, side or rear yard requirement except when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district, in which case the yard requirement shall be ten feet. |
| Minimum rear setback | None required Applies: 10 ft when the lot or an alley adjacent to it abuts an R district § 17.23.090 · code textUnless otherwise required in Chapters 17.48 through 17.52, establishing plan lines, or unless optional design standards have been used as set out in Section 17.23.100, there shall be no front, side or rear yard requirement except when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district, in which case the yard requirement shall be ten feet. |
| Maximum lot coverage | 100% Applies: less required parking and landscaping § 17.23.080 · code textThe maximum coverage of a lot by all structures may be one hundred percent, less required parking and landscaping. |
When a different number applies
The code sets other values for particular lots, buildings or locations in C-1-TD:
- Minimum front setback: 10 ft — when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district § 17.23.090
- Minimum side setback: 10 ft — when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district § 17.23.090
- Minimum rear setback: 10 ft — when a lot abuts a lot, or abuts an alley adjacent to a lot, in an R district § 17.23.090
Not on this page
We did not find a general lot size, FAR, density limit for C-1-TD in the zoning tables we read. The code may still set one elsewhere — check the King City Municipal Code.
Other King City zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in King City's C-1-TD zone?
30 ft — King City Municipal Code § 17.23.060.
What is the maximum number of stories in King City's C-1-TD zone?
2 stories — King City Municipal Code § 17.23.060.
What is the minimum front setback in King City's C-1-TD zone?
None required (10 ft when the lot or an alley adjacent to it abuts an R district) — King City Municipal Code § 17.23.090.
What is the minimum side setback in King City's C-1-TD zone?
None required (10 ft when the lot or an alley adjacent to it abuts an R district) — King City Municipal Code § 17.23.090.
What is the minimum rear setback in King City's C-1-TD zone?
None required (10 ft when the lot or an alley adjacent to it abuts an R district) — King City Municipal Code § 17.23.090.
General information, not legal advice.
Ask about a King City property in C-1-TD
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question