In Goleta's OI zone, buildings can be up to 35 ft tall and the front setback is 15 ft (Goleta code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 15 ft
  • Minimum side setback: 15 ft
  • Minimum rear setback: 15 ft (a corner lot backing on a key lot may reduce it to the key lot's required side setback or 10 ft, whichever is greater)
  • Maximum lot coverage: 40%
  • Maximum density: 20 units/acre

OI is a zoning district in Goleta. Every value below was read from the Goleta Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in OI

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.09.030 · code text
Table row “Maximum Building Height (ft.)”, column “OI”: 35
Minimum front setback
15 ft
§ 17.09.030 · code text
Table row “Front”, column “OI”: 15
Minimum side setback
15 ft
§ 17.09.030 · code text
Table row “Interior Side”, column “OI”: 15
Minimum rear setback
15 ft
Applies: a corner lot backing on a key lot may reduce it to the key lot's required side setback or 10 ft, whichever is greater
§ 17.09.030 · code text
Table row “Rear”, column “OI”: 15(A)
Maximum lot coverage
40%
§ 17.09.030 · code text
Table row “Maximum Lot Coverage”, column “OI”: 40%
Maximum density
20 units/acre
§ 17.09.030 · code text
Table row “Maximum Dwelling Unit Density (units/acre)”, column “OI”: 20

Uses in OI

Uses the code's use tables allow in OI, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, lot size, FAR limit for OI in the zoning tables we read. The code may still set one elsewhere — check the Goleta Municipal Code.

Other Goleta zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Goleta's OI zone?

35 ft — Goleta Municipal Code § 17.09.030.

What is the minimum front setback in Goleta's OI zone?

15 ft — Goleta Municipal Code § 17.09.030.

What is the minimum side setback in Goleta's OI zone?

15 ft — Goleta Municipal Code § 17.09.030.

What is the minimum rear setback in Goleta's OI zone?

15 ft (a corner lot backing on a key lot may reduce it to the key lot's required side setback or 10 ft, whichever is greater) — Goleta Municipal Code § 17.09.030.

What is the maximum lot coverage in Goleta's OI zone?

40% — Goleta Municipal Code § 17.09.030.

General information, not legal advice.

Ask about a Goleta property in OI

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.