In Eureka's DT zone, buildings can be up to 100 ft tall, the side setback limit is 0 ft and the rear setback limit is 0 ft (Eureka code, read October 2026).

Key points

  • Maximum building height: 100 ft
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft
  • Maximum floor area ratio (FAR): 6.0

DT (Downtown) is a zoning district in Eureka. Every value below was read from the Eureka Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in DT

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
100 ft
§ 155.208.030 · code text
Table row “Maximum (feet)”, column “Downtown DT”: 100 ft.
Minimum side setback
0 ft
§ 155.208.030 · code text
Table row “Interior”, column “Downtown DT”: 0 ft.
Minimum rear setback
0 ft
§ 155.208.030 · code text
Table row “Non-alley”, column “Downtown DT”: 0 ft.
Maximum floor area ratio (FAR)
6.0
§ 155.208.030 · code text
Table row “Maximum”, column “Downtown DT”: 6.0

Uses in DT

Uses the code's use tables allow in DT, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, front setback, lot size, lot coverage, density limit for DT in the zoning tables we read. The code may still set one elsewhere — check the Eureka Municipal Code.

Other Eureka zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Eureka's DT zone?

100 ft — Eureka Municipal Code § 155.208.030.

What is the minimum side setback in Eureka's DT zone?

0 ft — Eureka Municipal Code § 155.208.030.

What is the minimum rear setback in Eureka's DT zone?

0 ft — Eureka Municipal Code § 155.208.030.

What is the maximum floor area ratio (far) in Eureka's DT zone?

6.0 — Eureka Municipal Code § 155.208.030.

General information, not legal advice.

Ask about an Eureka property in DT

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Eureka