El Cerrito · Zoning · RD
El Cerrito RD zoning: height, setbacks and lot size
In El Cerrito's RD zone, generally buildings can be up to 30 ft tall, the front setback is 10 ft and the minimum lot size is 5,000 sq ft, with the conditions listed below (El Cerrito code, read October 2026).
Key points
- Maximum building height: 30 ft
- Minimum front setback: 10 ft (20 ft for the entire width of required covered parking)
- Minimum side setback: 5 ft
- Minimum rear setback: 15 ft
- Minimum lot size: 5,000 sq ft (Interior lots)
- Maximum lot coverage: 50% (Where lot slope is 30% or less)
RD is a zoning district in El Cerrito. Every value below was read from the El Cerrito Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in RD
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 30 ft § 19.06.030 · code textTable row “Maximum Height (ft.)”, column “RD”: Base Height 30; Maximum Height with CUP-35 |
|---|---|
| Minimum front setback | 10 ft Applies: 20 ft for the entire width of required covered parking § 19.06.030 · code textTable row “Front - Minimum”, column “RD”: 10 |
| Minimum side setback | 5 ft § 19.06.030 · code textTable row “Side”, column “RD”: 5 |
| Minimum rear setback | 15 ft § 19.06.030 · code textTable row “Rear”, column “RD”: 15 |
| Minimum lot size | 5,000 sq ft Applies: Interior lots § 19.06.030 · code textTable row “Interior Lots”, column “RD”: 5,000 |
| Maximum lot coverage | 50% Applies: Where lot slope is 30% or less § 19.06.030 · code textTable row “Where Lot Slope is 30% or Less”, column “RD”: 50 |
Uses in RD
Uses the code's use tables allow in RD, or allow with a permit. Each links to its page with the code section.
- Residential care home (7 or more) — Needs a conditional use permit
- Bed and breakfast — Needs an administrative use permit
- Child care center — Needs a conditional use permit
- Church or place of worship — Needs a conditional use permit
- Private school — Needs a conditional use permit
When a different number applies
The code sets other values for particular lots, buildings or locations in RD:
- Maximum building height: 35 ft — Maximum height with Conditional Use Permit § 19.06.030
- Minimum lot size: 6,000 sq ft — Corner lots § 19.06.030
- Maximum lot coverage: 40% — Where lot slope is greater than 30% § 19.06.030
Not on this page
We did not find a general stories, FAR, density limit for RD in the zoning tables we read. The code may still set one elsewhere — check the El Cerrito Municipal Code.
Other El Cerrito zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in El Cerrito's RD zone?
30 ft — El Cerrito Municipal Code § 19.06.030.
What is the minimum front setback in El Cerrito's RD zone?
10 ft (20 ft for the entire width of required covered parking) — El Cerrito Municipal Code § 19.06.030.
What is the minimum side setback in El Cerrito's RD zone?
5 ft — El Cerrito Municipal Code § 19.06.030.
What is the minimum rear setback in El Cerrito's RD zone?
15 ft — El Cerrito Municipal Code § 19.06.030.
What is the minimum lot size in El Cerrito's RD zone?
5,000 sq ft (interior lots) — El Cerrito Municipal Code § 19.06.030.
General information, not legal advice.
Ask about an El Cerrito property in RD
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question