Skip to content

Dublin · Zoning · C-2

Dublin C-2 zoning: height, setbacks and lot size

In Dublin's C-2 zone, generally buildings can be up to 45 feet tall, the front setback is 0 ft and the minimum lot size is 6,000 sq. ft., with the conditions listed below (Dublin code, read October 2026).

Key points

  • Maximum building height: 45 feet (35 ft instead if the principal structure is within 50 feet of an R zoning district)
  • Minimum front setback: 0 ft (unless the lot abuts an R, C-O or C-N zoning district; then the front setback of that district applies)
  • Minimum side setback: 0 ft (unless the lot abuts an R zoning district; then the side setback of that district applies)
  • Minimum rear setback: 0 ft (15 ft instead if the lot backs up on an R zoning district)
  • Minimum lot size: 6,000 sq. ft. (Interior lot)

C-2 is a zoning district in Dublin. Every value below was read from the Dublin Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 feet
Applies: 35 ft instead if the principal structure is within 50 feet of an R zoning district
§ 8.36.030 · code text
Table row “HEIGHT LIMITS”, column “C-2”: 45 feet (5)
Minimum front setback
0 ft
Applies: unless the lot abuts an R, C-O or C-N zoning district; then the front setback of that district applies
§ 8.36.030 · code text
Table row “Front”, column “C-2”: 0 feet (1)
Minimum side setback
0 ft
Applies: unless the lot abuts an R zoning district; then the side setback of that district applies
§ 8.36.030 · code text
Table row “Side”, column “C-2”: 0 feet (2)
Minimum rear setback
0 ft
Applies: 15 ft instead if the lot backs up on an R zoning district
§ 8.36.030 · code text
Table row “Rear”, column “C-2”: 0 feet (4)
Minimum lot size
6,000 sq. ft.
Applies: Interior lot
§ 8.36.030 · code text
Table row “Interior lot”, column “C-2”: 6,000 sq. ft.

Uses in C-2

Uses the code's use tables allow in C-2, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-2:

  • Maximum building height: 35 feet — if principal structure is within 50 feet of an R zoning district § 8.36.030
  • Minimum rear setback: 15 feet — if a C-1 or C-2 zoning district backs up on an R zoning district § 8.36.030
  • Minimum lot size: 7,000 sq. ft. — Corner lot § 8.36.030

Not on this page

We did not find a general stories, lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the Dublin Municipal Code.

Other Dublin zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Dublin's C-2 zone?

45 feet (35 ft instead if the principal structure is within 50 feet of an R zoning district) — Dublin Municipal Code § 8.36.030.

What is the minimum front setback in Dublin's C-2 zone?

0 ft (unless the lot abuts an R, C-O or C-N zoning district; then the front setback of that district applies) — Dublin Municipal Code § 8.36.030.

What is the minimum side setback in Dublin's C-2 zone?

0 ft (unless the lot abuts an R zoning district; then the side setback of that district applies) — Dublin Municipal Code § 8.36.030.

What is the minimum rear setback in Dublin's C-2 zone?

0 ft (15 ft instead if the lot backs up on an R zoning district) — Dublin Municipal Code § 8.36.030.

What is the minimum lot size in Dublin's C-2 zone?

6,000 sq. ft. (interior lot) — Dublin Municipal Code § 8.36.030.

General information, not legal advice.

Ask about a Dublin property in C-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Dublin