Duarte C-F zoning: height, setbacks and lot size

In Duarte's C-F zone, buildings can be up to 60 ft tall, the front setback is 15 ft and the minimum lot size is 40,000 sq ft (Duarte code, read October 2026).

Key points

  • Maximum building height: 60 ft
  • Minimum front setback: 15 ft
  • Minimum side setback: 0 ft (Abutting nonresidential)
  • Minimum lot size: 40,000 sq ft
  • Maximum floor area ratio (FAR): 0.50

C-F is a zoning district in Duarte. Every value below was read from the Duarte Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-F

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
60 ft
§ 19.12.030 · code text
Table row “Height — maximum”, column “C-F”: 60 ft
Minimum front setback
15 ft
§ 19.12.030 · code text
Table row “Front or adjacent to a street”, column “C-F”: 15 ft
Minimum side setback
0 ft
Applies: Abutting nonresidential
§ 19.12.030 · code text
Table row “Abutting nonresidential”, column “C-F”: 0 ft
Minimum lot size
40,000 sq ft
§ 19.12.030 · code text
Table row “Lot Area — minimum”, column “C-F”: 40,000 sf
Maximum floor area ratio (FAR)
0.50
§ 19.12.030 · code text
Table row “Floor-Area Ratio — maximum”, column “C-F”: 0.50

When a different number applies

The code sets other values for particular lots, buildings or locations in C-F:

  • Minimum side setback: 25 ft — Abutting residential § 19.12.030
  • Minimum side setback: 15 ft — Street side § 19.12.030
  • Minimum rear setback: 15 ft — Abutting alley § 19.12.030
  • Minimum rear setback: 20 ft — Abutting residential § 19.12.030

Not on this page

We did not find a general stories, rear setback, lot coverage, density limit for C-F in the zoning tables we read. The code may still set one elsewhere — check the Duarte Municipal Code.

Other Duarte zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Duarte's C-F zone?

60 ft — Duarte Municipal Code § 19.12.030.

What is the minimum front setback in Duarte's C-F zone?

15 ft — Duarte Municipal Code § 19.12.030.

What is the minimum side setback in Duarte's C-F zone?

0 ft (abutting nonresidential) — Duarte Municipal Code § 19.12.030.

What is the minimum lot size in Duarte's C-F zone?

40,000 sq ft — Duarte Municipal Code § 19.12.030.

What is the maximum floor area ratio (far) in Duarte's C-F zone?

0.50 — Duarte Municipal Code § 19.12.030.