Skip to content

Downey · Zoning · R-3-O

Downey R-3-O zoning: height, setbacks and lot size

In Downey's R-3-O zone, buildings can be up to 3 stories, the front setback is 15 ft and the minimum lot size is 10,000 sq ft (Downey code, read October 2026).

Key points

  • Maximum number of stories: 3 stories
  • Minimum front setback: 15 ft
  • Minimum side setback: 5 ft
  • Minimum lot size: 10,000 sq ft
  • Maximum lot coverage: 50%

R-3-O is a zoning district in Downey. Every value below was read from the Downey Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-3-O

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum number of stories
3 stories
§ 9312.08 · code text
Table row “Building height — maximum (feet) main building”, column “R-3-O”: 35 feet or three stories, whichever is less a
Minimum front setback
15 ft
§ 9312.08 · code text
Table row “front”, column “R-3-O”: 15
Minimum side setback
5 ft
§ 9312.08 · code text
Table row “interior”, column “R-3-O”: 5 c
Minimum lot size
10,000 sq ft
§ 9312.08 · code text
Table row “Lot area — minimum (sq. ft.)”, column “R-3-O”: 10,000
Maximum lot coverage
50%
§ 9312.08 · code text
Table row “Lot coverage — maximum (percent)”, column “R-3-O”: 50

Uses in R-3-O

Uses the code's use tables allow in R-3-O, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-3-O:

  • Minimum side setback: 10 ft — When abutting the R-1 Zone § 9312.08
  • Minimum rear setback: 20 ft — Rear yard area abuts an R-1 Zone and building is one story § 9312.08
  • Minimum rear setback: 30 ft — Rear yard area abuts an R-1 Zone and building is two-story § 9312.08
  • Minimum rear setback: 46 ft — Rear yard area abuts an R-1 Zone and building is three-story § 9312.08
  • Minimum rear setback: None required — Rear yard abuts a fully dedicated public alley and the building is one story § 9312.08

Not on this page

We did not find a general height, rear setback, FAR, density limit for R-3-O in the zoning tables we read. The code may still set one elsewhere — check the Downey Municipal Code.

Other Downey zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum number of stories in Downey's R-3-O zone?

3 stories — Downey Municipal Code § 9312.08.

What is the minimum front setback in Downey's R-3-O zone?

15 ft — Downey Municipal Code § 9312.08.

What is the minimum side setback in Downey's R-3-O zone?

5 ft — Downey Municipal Code § 9312.08.

What is the minimum lot size in Downey's R-3-O zone?

10,000 sq ft — Downey Municipal Code § 9312.08.

What is the maximum lot coverage in Downey's R-3-O zone?

50% — Downey Municipal Code § 9312.08.

General information, not legal advice.

Ask about a Downey property in R-3-O

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Downey