In Danville's M-35 zone, buildings can be up to 3 stories, the front setback is 25 ft and the minimum lot size is No minimum (Danville code, read October 2026).

Key points

  • Maximum number of stories: 3 stories
  • Minimum front setback: 25 ft
  • Minimum side setback: 20 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: No minimum
  • Maximum floor area ratio (FAR): 120%
  • Maximum density: 35 units per gross acre

M-35 (Multifamily Residential District) is a zoning district in Danville. Every value below was read from the Danville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in M-35

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum number of stories
3 stories
§ 32-29.9 · code text
The maximum allowable story height is three (3) stories.
Minimum front setback
25 ft
§ 32-29.9 · code text
The minimum front yard setback shall be twenty-five (25) feet.
Minimum side setback
20 ft
§ 32-29.9 · code text
The minimum side yard setback shall be twenty (20) feet.
Minimum rear setback
20 ft
§ 32-29.9 · code text
The minimum rear yard setback shall be twenty (20) feet.
Minimum lot size
No minimum
§ 32-29.7 · code text
No minimum lot area required.
Maximum floor area ratio (FAR)
120%
§ 32-29.9 · code text
The maximum allowable net floor area ratio (FAR) is one hundred twenty percent (120%) of the net land area available for development, as determined by a planning entitlement deemed complete for processing.
Maximum density
35 units per gross acre
§ 32-29.6 · code text
The maximum residential density allowed in this district is thirty-five (35) units per gross acre.

When a different number applies

The code sets other values for particular lots, buildings or locations in M-35:

  • Minimum side setback: 50 ft — For development sites that abut a single family residential neighborhood, to any second story building elements § 32-29.9
  • Minimum rear setback: 50 ft — For development sites that abut a single family residential neighborhood, to any second story building elements § 32-29.9

Not on this page

We did not find a general height, lot coverage limit for M-35 in the zoning tables we read. The code may still set one elsewhere — check the Danville Municipal Code.

Other Danville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum number of stories in Danville's M-35 zone?

3 stories — Danville Municipal Code § 32-29.9.

What is the minimum front setback in Danville's M-35 zone?

25 ft — Danville Municipal Code § 32-29.9.

What is the minimum side setback in Danville's M-35 zone?

20 ft — Danville Municipal Code § 32-29.9.

What is the minimum rear setback in Danville's M-35 zone?

20 ft — Danville Municipal Code § 32-29.9.

What is the minimum lot size in Danville's M-35 zone?

No minimum — Danville Municipal Code § 32-29.7.