Cudahy’s development standards live in Title 20 of the Cudahy Municipal Code and set the dimensional and form rules—setbacks, height, lot size/width, floor area ratio (FAR), open space, and residential density—for each mapped zone. The core chapters are Residential (§ 20.16), Commercial/Industrial (§ 20.20), Mixed-Use (§ 20.28), and General Development Standards (§ 20.56) . Use allowances are set in zone-specific tables, while citywide rules (e.g., how height is measured, what can project into a setback) apply everywhere. For process and site-planning context, see the city’s zoning, land use, parking, and design review pages.

The single most important reading cue in Cudahy’s code: numbers in the zone tables control. Then check the “General Development Standards” for measurement rules and exceptions (e.g., projections, adjacency buffers, height measurement) in § 20.56 .


Citywide rules you will use on almost every project

  • How height is measured. Vertical distance from average finished grade to the roof’s highest point; certain rooftop elements can exceed the limit if they don’t add floor area (§ 20.56.060) .
  • Setback mechanics and projections. Average front yard on partially developed blocks; side-yard sizing rules for narrow lots; what can project 3 ft into yards; distance between buildings (10 ft between main buildings; 5 ft to accessory with one-hour rating) (§ 20.56.050) .
  • FAR controls. Don’t exceed the zone’s FAR; special handling when a building straddles zone boundaries (§ 20.56.120(D)) .
  • Landscaping. Front-yard hardscape in residential zones is capped at 40% of the front setback; water-efficient landscaping follows the State MWELO (§ 20.56.110) . See also Landscaping and Screening.
  • Open space for residential. In MDR/HDR and in mixed-use residential components: total 280 sf per dwelling unit and private open space 100 sf per unit; dimensional and accessibility rules apply (§ 20.16.060, § 20.28.070) .
  • Development Review (process). New construction requires a development review permit; major/minor thresholds are in Table 20.84-2 (§ 20.84.180)—see Design Review .
  • Relief/adjustments. A Planned Development Permit can modify most development standards (not density) with findings (§ 20.84.400–.420)—see Variances and Exceptions .

District-by-District Standards

Low Density Residential (LDR)

  • Purpose and uses: Detached/attached units (e.g., small-lot, duplex/triplex, townhouses) up to 15 du/ac; complementary residential uses allowed (§ 20.16.010(A)) .
  • Key standards:
    • Lot area/width: 5,000 sf min; 50 ft width; 60 ft on corner lots (§ 20.16.030; § 20.16.040) .
    • Setbacks: Front 20 ft; side 5 ft (corner side street typically 15 ft); rear 10 ft. Side yards increase with additional stories; see note under Risks below (§ 20.16.030; § 20.56.050) .
    • Height: Max 2 stories / 35 ft (whichever is less) (§ 20.16.030) .
    • Open space (if multi-unit): Total 280 sf/du; private open space rules per § 20.16.060 .
  • Where it applies: All parcels mapped LDR on the City zoning map.

Medium Density Residential (MDR)

  • Purpose and uses: Row houses, townhouses, stacked flats, apartments up to 25 du/ac (§ 20.16.010(B)) .
  • Key standards:
    • Lot area/width: 6,000 sf; 50 ft width; 60 ft corner (§ 20.16.030) .
    • Setbacks: Front 15 ft; side 5 ft (+ increased width above one story); rear 5 ft minimum, with a general 10 ft noted for multi-story conditions—verify on project (§ 20.16.030; § 20.56.050) .
    • Height: Max 3 stories / 45 ft (§ 20.16.030) .
    • Open space: Total 280 sf/du; private 100 sf/du (§ 20.16.030; § 20.16.060) .

High Density Residential (HDR)

  • Purpose and uses: Higher-density multi-story housing near transit/services; max 40 du/ac and a minimum of 20 du/ac in some contexts (§ 20.16.010(C); § 20.16.030) .
  • Key standards:
    • Lot area/width: 6,000 sf; 50 ft width; 60 ft corner (§ 20.16.030) .
    • Setbacks: Front 15 ft; side 5 ft (+ increased width above one story); rear 5 ft minimum; multi-story general rear 10 ft—verify on project (§ 20.16.030; § 20.56.050) .
    • Height: Max 4 stories / 55 ft (§ 20.16.030) .
    • Open space: Total 280 sf/du; private 100 sf/du (§ 20.16.030; § 20.16.060) .
  • Extra residential design triggers (all residential zones): massing, tree counts, driveway surfacing, undergrounding utilities (§ 20.16.130) . ADUs follow their own state-driven rules; see ADUs.

Neighborhood Commercial (NC)

  • Purpose and uses: Neighborhood-serving retail/services outside Atlantic Ave core (§ 20.20.010(A)) .
  • Key standards:
    • Setbacks: Front/side street 10 ft; side 10 ft; rear 10 ft. Adjacent to residential: side 10 ft, rear 20 ft (§ 20.20.030; Table 20.20-2) .
    • FAR/height: Max FAR 0.5; max 2 stories (§ 20.20.030; § 20.56.060) .
  • Notes: Signs separate; see Signage.

Entertainment (Ent)

  • Purpose and uses: Mixed entertainment-commercial district; residential allowed only as part of mixed-use and never on the ground floor; residential floor area must be < two-thirds of total (§ 20.20.020; Residential Uses in Entertainment Zone) .
  • Key standards:
    • Setbacks: Front/side/rear can be 0 ft; but when adjacent to residential: side 10 ft, rear 10 ft (§ 20.20.030; Table 20.20-2) .
    • FAR/height: Max FAR 2.0; number of stories 4 + 4 (extra stories only with defined “community benefits” and Council approval) (§ 20.20.030(C); § 20.56.060) .
    • If residential included: Open space standards apply (Total 280 sf/du, Private 100 sf/du) (§ 20.20.030; Table 20.20-2) .
  • Design cross-application: Mixed-use design standards apply to Ent for mixed-use projects (§ 20.20.030(D)) .

Industrial – I-Ind

  • Purpose and uses: Industrial with allowance for certain live/work and limited commercial; industrial performance limits apply (e.g., horsepower limits on certain equipment) (§ 20.20.020; Industrial equipment limits) .
  • Key standards:
    • Setbacks: Front 0–10 ft; side 0 ft; rear 0 ft. When adjacent to residential: side 10 ft, rear 30 ft (§ 20.20.030; Table 20.20-2) .
    • FAR/height: Max FAR 1.25 (commercial-only 1.0; live/work 1.5); max 3 stories (§ 20.20.030; § 20.56.060) .
    • Residential density (where allowed): 30 du/ac per table note (§ 20.20.030; Table 20.20-2) .

Light Industrial (LI)

  • Purpose and uses: Lighter-intensity industrial; adjacency buffers to residential apply.
  • Key standards:
    • Setbacks: Front/side street 10 ft; side 0 ft; rear 0 ft. Adjacent to residential: side 10 ft, rear 30 ft (§ 20.20.030; Table 20.20-2) .
    • Lot depth: 200 ft min (§ 20.20.030; Table 20.20-2) .
    • FAR/height: Max FAR 1.25; max 3 stories (§ 20.20.030; § 20.56.060) .

Commercial Mixed-Use (CMU)

  • Purpose and uses: Most concentrated commercial hub; mixed-use and residential allowed with street-activation on Atlantic Ave; ground-floor residential limited and must not face Atlantic (§ 20.28.010–.020) .
  • Key standards (selected):
    • Lot/width: 6,000 sf lot; 60 ft width. Front: 0 ft (but ground-floor residential needs 10 ft front); Side: 0–10 ft (ground-floor res min 10 ft); Rear: 0–10 ft (ground-floor res min 10 ft). Adjacent to residential: 10 ft setback (§ 20.28.030; Table 20.28-2) .
    • FAR: 0.75 commercial-only; 1.5 mixed-use (§ 20.28.030; Table 20.28-2) .
    • Residential density: Mixed-use max 40 du/ac; residential-only max 30 du/ac; minimum 20 du/ac for residential-only (§ 20.28.030; Table 20.28-2) .
    • Heights (stories): Mixed-use 4 + 2; commercial-only 4; residential-only 3; “+” increments require Council-approved community benefits (§ 20.28.050(A); § 20.56.060) .
    • Residential open space: Total 280 sf/du; private 100 sf/du; detailed design/lighting and plaza rules apply in CivicMU and generally guide CMU site design (§ 20.28.070) .

Civic Mixed-Use (CivicMU)

  • Purpose and uses: Commercial, residential, and civic activities with public plazas/amenities (§ 20.28.010(B)) .
  • Key standards:
    • Setbacks: Same structure as CMU; ground-floor residential adds 10 ft front/side/rear minimums; 10 ft where adjacent to residential (§ 20.28.030; Table 20.28-2) .
    • FAR: 1.25 commercial-only; 1.5 mixed-use (§ 20.28.030; Table 20.28-2) .
    • Density: Same as CMU (§ 20.28.030; Table 20.28-2) .
    • Heights (stories): Mixed-use 4 + 1; commercial-only 4 + 1; residential-only 4 + 1 with community-benefit path for any “+” (§ 20.28.050(A); § 20.56.060) .

Parks, Schools, and Los Angeles River zones

  • Uses are primarily civic/open space; many development standards are set through approvals like CUPs per § 20.24.020 (development standards determined in the CUP) . Not found in retrieved materials: district-specific numeric setbacks/heights for these zones.

Quick-View Tables

Residential and Mixed-Use Key Dimensional Standards

Zone Front/Side/Rear Setback Max Height (stories/ft) Density (du/ac) Open Space (res) Code Reference
LDR 20 / 5 / 10 ft; corner side street 15 ft; side increases with stories 2 / 35 Max 15 If multi-unit: 280 sf/du (private per § 20.16.060) § 20.16.030; § 20.56.050
MDR 15 / 5 / 5–10 ft (verify rear for multi-story) 3 / 45 Max 25 280 sf/du; 100 sf private § 20.16.030; § 20.16.060
HDR 15 / 5 / 5–10 ft (verify rear for multi-story) 4 / 55 20–40 280 sf/du; 100 sf private § 20.16.030; § 20.16.060
CMU 0–10 / 0–10 / 0–10 ft; ground-floor res min 10 ft; 10 ft adj. to res 4+2 MU; 4 CO; 3 RO MU ≤ 40; RO ≤ 30; RO min 20 280 sf/du; 100 sf private § 20.28.030–.070; § 20.28.050(A)
CivicMU 0–10 / 0–10 / 0–10 ft; ground-floor res min 10 ft; 10 ft adj. to res 4+1 MU/CO/RO MU ≤ 40; RO ≤ 30; RO min 20 280 sf/du; 100 sf private § 20.28.030–.070; § 20.28.050(A)

Notes: MU = Mixed-use; CO = Commercial-only; RO = Residential-only. “+” stories require community benefits and City Council approval (§ 20.28.050(A)) .

Commercial/Industrial Key Dimensional Standards

Zone Front/Side/Rear Setback Adjacent-to-Res. Buffers Max FAR Max Stories Code Reference
NC 10 / 10 / 10 ft Side 10 ft; Rear 20 ft 0.5 2 § 20.20.030; Table 20.20-2
Ent 0 / 0 / 0 ft Side 10 ft; Rear 10 ft 2.0 4 + 4 § 20.20.030(C–D)
I-Ind 0–10 / 0 / 0 ft Side 10 ft; Rear 30 ft 1.25 (1.5 live/work) 3 § 20.20.030; Table 20.20-2
LI 10 / 0 / 0 ft; Lot depth 200 ft Side 10 ft; Rear 30 ft 1.25 3 § 20.20.030; Table 20.20-2

Practical cross-references and exceptions

  • Mixed-use design requirements and open space-sharing rules are spelled out in § 20.28.050–.080; the CivicMU zone expects visible, well-lit plazas and paseos (§ 20.28.070(B)) .
  • In the Entertainment zone, mixed-use design standards from the mixed-use chapter apply to mixed-use projects (§ 20.20.030(D)) .
  • Density Bonus projects may request on-menu concessions that adjust side yards, distance between buildings, minimum unit size, and certain mixed-use ratios; “zones with no density maximum” (like ENT) require a base density study (§ 20.52.320(D); § 20.52.330) . See California housing laws.
  • For overlays (e.g., Riverfront -R, Urban Agriculture -UA), overlay standards can add or limit what the base zone allows. The Riverfront Overlay is a holding zone that could introduce high-density/mixed-use if regional plans advance (§ 20.32.010) . See Overlay Districts.
  • Existing sites may be “legal nonconforming” and follow separate continuity and alteration rules; see Nonconforming Uses and § 20.80 referenced in § 20.16.140 .

Checklist

  • Confirm your parcel’s base zone and any overlays on the City zoning map; read the correct zone table in § 20.16, § 20.20, or § 20.28 .
  • Apply citywide rules (height measurement, yard projections, FAR) in § 20.56 .
  • If adjacent to residential, add the required buffers from the commercial/industrial/mixed-use tables (§ 20.20.030; § 20.28.030) .
  • For residential or mixed-use, show open space compliance (280 sf/du total; 100 sf private where required) (§ 20.16.060; § 20.28.070) .
  • Prepare a design review submittal; confirm whether Major or Minor DR is required (§ 20.84.180) .
  • Verify parking per § 20.64 and any mixed-use sharing allowances .
  • If seeking flexibility, consider a Planned Development Permit to adjust standards except density (§ 20.84.400(D)) .
  • Coordinate signage under Signage rules (separate chapter).
  • Confirm any overlay-specific constraints (e.g., Riverfront -R) in § 20.32 .

Risks & Ambiguities

Issue Why it matters What to verify
Side-yard increase per additional story in residential zones Table 20.16-2 says side yards “shall be increased two feet” above one story; § 20.56.050(B)(1)(b) elsewhere says one foot per additional story Ask staff which provision controls for your zone; document in design review submittal. Cite § 20.16.030 and § 20.56.050 in plans
MDR/HDR rear yard for multi-story buildings Table shows 5 ft rear minimum but also a general 10 ft note for two+ stories Confirm the correct rear setback for your building height with the planner; cite § 20.16.030 on plans
Residential in Industrial (I-Ind) Table provides a 30 du/ac figure but residential use may be limited (e.g., live/work) Verify allowable residential forms in I-Ind for your site and entitlement path (e.g., CUP) under § 20.20.020/030
“+” extra stories in CMU/CivicMU/Ent Extra stories require City Council approval and “community benefit” package Confirm eligibility and benefits under § 20.28.050(A) or § 20.20.030(C) before design assumes added floors
Entertainment Zone residential limits Residential must be part of mixed-use and not on ground floor; overall res share < 2/3 Make program/drawings reflect § 20.20.020 and Ent notes; planning will check at DR/CUP
Shared open space in mixed-use Up to 30% of res-required open space may be in nonres component If using the share, show calculations and access per § 20.28.070(D)(1)

Plain-English Summary

Cudahy assigns each parcel to a zone with its own numbers for lot size, setbacks, height, FAR, and—if housing—density and open space. Start with your zone’s table, then layer on the general rules (how to measure height, what can encroach into setbacks, adjacency buffers). Mixed-use and the Entertainment zone have their own twists—extra stories can be granted for community benefits, and housing in Entertainment must be upstairs and part of a true mixed-use project. When the strict numbers don’t fit, a Planned Development Permit can often tailor standards (but not density).

Source References

  • Residential zones: § 20.16.010–.060, .130–.140 (standards, design, cross-refs) .
  • Commercial/Industrial zones: § 20.20.010–.030 (intent, uses, development standards) .
  • Mixed-Use zones: § 20.28.010–.070 (use mix, tables, building/height, open space) .
  • General Development Standards: § 20.56.050 (yards), § 20.56.060 (height), § 20.56.110 (landscaping), § 20.56.120(D) (FAR) .
  • Entertainment zone mixed-use design cross-application and “+” height: § 20.20.030(C–D) .
  • Density bonus mechanics (zones w/o density max; on-menu concessions): § 20.52.320(D); § 20.52.330(B) .
  • Parks/Schools/LA River zones: § 20.24.020 (uses; standards by CUP) .
  • Overlays (Riverfront; Urban Agriculture): § 20.32.010 et seq. .

Sources

Retrieved passages

  • Cudahy Zoning Code (§ 6) High relevance
  • Cudahy Zoning Code (Title 20) High relevance
  • Cudahy Zoning Code (Title 20) High relevance
  • CMC § 20.28.040 (Title 20) High relevance
  • CFC § 4 (Title 20) High relevance
  • Cudahy Zoning Code (Title 20) High relevance
  • CFC § 4 (Chapter 20.84) High relevance
  • CMC § 4 (section if) High relevance
  • Cudahy Zoning Code (Title 20) High relevance
  • CMC § 6 (Section 65915) High relevance
  • CMC § 20.20.040 (Title 20) High relevance
  • CMC § 6 (Chapter 20.52) Medium relevance
  • Cudahy Zoning Code (Title 20) Medium relevance
  • Cudahy Zoning Code (§ 9) Medium relevance
  • CMC § 6 (Title 20) High relevance
  • CMC § 20.56.050 (§ 6) High relevance
  • Cudahy Zoning Code (§ 6) High relevance
  • CMC § 20.16.060 (Chapter 20.84) High relevance
  • CMC § 9.04.020 (Title 22) High relevance
  • Cudahy Zoning Code (§ 4) High relevance
  • CMC § 20.16.120 (Title 20) Medium relevance
  • CMC § 6 (Chapter 20.52) Medium relevance

Cited sections

  • Residential zones: § 20.16.010–.060, .130–.140 (standards, design, cross-refs) . (§ 20.16.010)
  • Commercial/Industrial zones: § 20.20.010–.030 (intent, uses, development standards) . (§ 20.20.010)
  • Mixed-Use zones: § 20.28.010–.070 (use mix, tables, building/height, open space) . (§ 20.28.010)
  • General Development Standards: § 20.56.050 (yards), § 20.56.060 (height), § 20.56.110 (landscaping), § 20.56.120(D) (FAR) . (§ 20.56.050)
  • Entertainment zone mixed-use design cross-application and “+” height: § 20.20.030(C–D) . (§ 20.20.030)
  • Density bonus mechanics (zones w/o density max; on-menu concessions): § 20.52.320(D); § 20.52.330(B) . (§ 20.52.320)
  • Parks/Schools/LA River zones: § 20.24.020 (uses; standards by CUP) . (§ 20.24.020)
  • Overlays (Riverfront; Urban Agriculture): § 20.32.010 et seq. . (§ 20.32.010)
  • Cudahy_ZoningCode.md

Frequently asked questions

What can I build on an LDR lot in Cudahy?

Detached or attached homes (including duplexes/triplexes and small-lot townhomes) are allowed up to 15 du/ac. Typical setbacks are 20 ft front, 5 ft sides (increasing with additional stories), and 10 ft rear; max height is 2 stories/35 ft (§ 20.16.010(A); § 20.16.030) .

What are the MDR/HDR setback and height rules?

MDR: 15 ft front, 5 ft side (increasing above one story), 5–10 ft rear depending on building height; max 3 stories/45 ft. HDR: 15 ft front, 5 ft side (increasing above one story), 5–10 ft rear; max 4 stories/55 ft (§ 20.16.030; § 20.56.050) .

How does height “+” work in CMU/CivicMU and Entertainment?

If the table shows a “+”, you may request extra stories in exchange for defined community benefits (e.g., affordable units, public facilities). Approval is by City Council (§ 20.28.050(A); § 20.20.030(C)) .

Can I put housing in the Entertainment zone?

Yes, but only as part of a mixed-use project, never on the ground floor, and housing must be less than two-thirds of total floor area (§ 20.20.020; “Residential Uses in Entertainment Zone”) .

What buffers apply if my commercial/industrial site touches a residential lot?

Add adjacency setbacks from the zone table. For example, Ent requires 10 ft side and 10 ft rear; I-Ind/LI require 10 ft side and 30 ft rear along the shared boundary (§ 20.20.030; Table 20.20-2) .

What open space is required for apartments or mixed-use housing?

Provide 280 sf of total open space per dwelling unit; at least 100 sf must be private per unit (balcony/patio, etc.), with specific size/access rules. Mixed-use projects follow the same residential open space standards and can share up to 30% in some horizontal layouts (§ 20.16.060; § 20.28.070) .

Do I need design review before building?

Yes—new construction needs a development review permit. Whether it’s Major or Minor depends on project scope (Table 20.84-2) (§ 20.84.180) .

Can the City modify setbacks or height if my site is constrained?

Yes. Through a Planned Development Permit the City can tailor most standards (not density) if findings are met (§ 20.84.400–.420). Density Bonus projects have separate concession menus (§ 20.52.330) .

How is building height measured?

From the average finished grade to the highest roof point; specific rooftop features can exceed if they don’t add floor area (§ 20.56.060) .

Where do overlay rules fit?

Overlays can add or limit what the base zone allows. The Riverfront Overlay (-R) is a holding tool for potential high-density/mixed-use near the LA River if regional plans advance (§ 20.32.010) .

More in Cudahy code

Ask about any Cudahy property

Get a cited, plain-English answer on Cudahy zoning, setbacks, FAR, ADUs and permits — for any address.

Start Free Trial

More Cudahy zoning topics