In Crescent City's R-3 zone, generally buildings can be up to 35 ft tall, the front setback is 10 ft and the minimum lot size is 6,000 sq ft, with the conditions listed below (Crescent City code, read October 2026).

Key points

  • Maximum building height: 35 ft (Main building)
  • Minimum front setback: 10 ft (All buildings)
  • Minimum side setback: 5 ft (Interior side yard)
  • Minimum rear setback: 10 ft (Main buildings)
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 65% (All buildings and structures)
  • Maximum density: 30 units per acre

R-3 (High Density Residential District) is a zoning district in Crescent City. Every value below was read from the Crescent City Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: Main building
§ 17.16.030 · code text
Main Building. Maximum thirty-five feet; and
Minimum front setback
10 ft
Applies: All buildings
§ 17.16.030 · code text
All buildings. Minimum ten feet.
Minimum side setback
5 ft
Applies: Interior side yard
§ 17.16.030 · code text
Interior. Minimum five feet.
Minimum rear setback
10 ft
Applies: Main buildings
§ 17.16.030 · code text
Main Buildings. Minimum ten feet.
Minimum lot size
6,000 sq ft
§ 17.16.030 · code text
Minimum six thousand square feet.
Maximum lot coverage
65%
Applies: All buildings and structures
§ 17.16.030 · code text
Maximum sixty-five percent for all buildings and structures.
Maximum density
30 units per acre
§ 17.16.030 · code text
Maximum thirty dwelling units per acre.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-3:

  • Minimum front setback: 20 ft — Garage doors and carport entrances § 17.16.030
  • Minimum side setback: 10 ft — Exterior side yard § 17.16.030
  • Minimum rear setback: 5 ft — Accessory buildings § 17.16.030
  • Maximum density: 1 unit per 4,300 sq ft — Mobile home parks § 17.16.030

Not on this page

We did not find a general stories, FAR limit for R-3 in the zoning tables we read. The code may still set one elsewhere — check the Crescent City Municipal Code.

Other Crescent City zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Crescent City's R-3 zone?

35 ft (main building) — Crescent City Municipal Code § 17.16.030.

What is the minimum front setback in Crescent City's R-3 zone?

10 ft (all buildings) — Crescent City Municipal Code § 17.16.030.

What is the minimum side setback in Crescent City's R-3 zone?

5 ft (interior side yard) — Crescent City Municipal Code § 17.16.030.

What is the minimum rear setback in Crescent City's R-3 zone?

10 ft (main buildings) — Crescent City Municipal Code § 17.16.030.

What is the minimum lot size in Crescent City's R-3 zone?

6,000 sq ft — Crescent City Municipal Code § 17.16.030.

General information, not legal advice.

Ask about a Crescent City property in R-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question