Skip to content

Cloverdale · Zoning · R-2

Cloverdale R-2 zoning: height, setbacks and lot size

In Cloverdale's R-2 zone, generally buildings can be up to 35 ft (2 stories) tall, the front setback is 20 ft and the minimum lot size is 6,000 sf, with the conditions listed below (Cloverdale code, read October 2026).

Key points

  • Maximum building height: 35 ft (accessory buildings are limited to 14 ft)
  • Maximum number of stories: 2 stories
  • Minimum front setback: 20 ft
  • Minimum side setback: 5 ft (Interior side setback for a 1-story or lower story of a 2-story residence)
  • Minimum rear setback: 20 ft (One-story building)
  • Minimum lot size: 6,000 sf (Interior lot)
  • Maximum floor area ratio (FAR): 0.35 (0—4,000 sf net site)
  • Maximum density: 8.0 units per net acre

R-2 is a zoning district in Cloverdale. Every value below was read from the Cloverdale Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: accessory buildings are limited to 14 ft
§ 18.04.050 · code text
Table row “Building height (maximum)”, column “R-2”: 35' or 2 stories, whichever is less. 14' for accessory buildings.
Maximum number of stories
2 stories
§ 18.04.050 · code text
Table row “Building height (maximum)”, column “R-2”: 35' or 2 stories, whichever is less. 14' for accessory buildings.
Minimum front setback
20 ft
§ 18.04.050 · code text
Table row “Front setback 5,6 (minimum)”, column “R-2”: 20'
Minimum side setback
5 ft
Applies: Interior side setback for a 1-story or lower story of a 2-story residence
§ 18.04.050 · code text
Table row “• Interior”, column “R-2”: 1 story or lower story of a 2-story residence: 5' 2nd story of 2-story residence: 10'
Minimum rear setback
20 ft
Applies: One-story building
§ 18.04.050 · code text
Table row “• One-story building”, column “R-2”: 20'
Minimum lot size
6,000 sf
Applies: Interior lot
§ 18.04.050 · code text
Table row “• Interior lot”, column “R-2”: 6,000 sf
Maximum floor area ratio (FAR)
0.35
Applies: 0—4,000 sf net site
§ 18.04.050 · code text
Table row “• 0—4,000 sf net site”, column “R-2”: 0.35
Maximum density
8.0 units per net acre
See note 7 below the table in the code.
§ 18.04.050 · code text
Table row “Density 7 (maximum units per net acre)”, column “R-2”: 8.0
Note 7: Densities may be increased as provided for under State Density Bonus Law and/or Chapter 18.13 .

Uses in R-2

Uses the code's use tables allow in R-2, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-2:

  • Minimum side setback: 10 ft — Interior side setback for 2nd story of 2-story residence § 18.04.050
  • Minimum lot size: 7,000 sf — Corner lot § 18.04.050
  • Maximum floor area ratio (FAR): 0.40 — 4,001 sf and larger net site § 18.04.050

Not on this page

We did not find a general lot coverage limit for R-2 in the zoning tables we read. The code may still set one elsewhere — check the Cloverdale Municipal Code.

Other Cloverdale zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Cloverdale's R-2 zone?

35 ft (accessory buildings are limited to 14 ft) — Cloverdale Municipal Code § 18.04.050.

What is the maximum number of stories in Cloverdale's R-2 zone?

2 stories — Cloverdale Municipal Code § 18.04.050.

What is the minimum front setback in Cloverdale's R-2 zone?

20 ft — Cloverdale Municipal Code § 18.04.050.

What is the minimum side setback in Cloverdale's R-2 zone?

5 ft (interior side setback for a 1-story or lower story of a 2-story residence) — Cloverdale Municipal Code § 18.04.050.

What is the minimum rear setback in Cloverdale's R-2 zone?

20 ft (one-story building) — Cloverdale Municipal Code § 18.04.050.

General information, not legal advice.

Ask about a Cloverdale property in R-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Cloverdale