Skip to content

Chino · Zoning · RD 1

Chino RD 1 zoning: height, setbacks and lot size

In Chino's RD 1 zone, generally buildings can be up to 35 feet (2-1/2 stories) tall, the front setback is 25 feet and the minimum lot size is 1 acre, with the conditions listed below (Chino code, read October 2026).

Key points

  • Maximum building height: 35 feet
  • Maximum number of stories: 2-1/2 stories
  • Minimum front setback: 25 feet (Add five feet along primary and secondary arterial streets.)
  • Minimum side setback: 10 feet
  • Minimum rear setback: 25 feet (Add five feet along primary and secondary arterial streets.)
  • Minimum lot size: 1 acre (Applies only to creation of new lots)
  • Maximum lot coverage: 25%
  • Maximum floor area ratio (FAR): 0.20
  • Maximum density: 1 du/acre

RD 1 is a zoning district in Chino. Every value below was read from the Chino Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RD 1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 feet
§ 20.04.040 · code text
Table row “Feet”, column “RD 1”: 35 feet
Maximum number of stories
2-1/2 stories
§ 20.04.040 · code text
Table row “Stories”, column “RD 1”: 2-1/2
Minimum front setback
25 feet
Applies: Add five feet along primary and secondary arterial streets.
§ 20.04.040 · code text
Table row “Front”, column “RD 1”: 25 feet
Minimum side setback
10 feet
§ 20.04.040 · code text
Table row “Interior Side”, column “RD 1”: 10 feet
Minimum rear setback
25 feet
Applies: Add five feet along primary and secondary arterial streets.
§ 20.04.040 · code text
Table row “Rear”, column “RD 1”: 25 feet
Minimum lot size
1 acre
Applies: Applies only to creation of new lots
§ 20.04.040 · code text
Table row “Lot Area, Minimum”, column “RD 1”: 1 acre
Maximum lot coverage
25%
§ 20.04.040 · code text
Table row “Lot Coverage, Maximum”, column “RD 1”: 25%
Maximum floor area ratio (FAR)
0.20
§ 20.04.040 · code text
Table row “Floor Area Ratio, Maximum”, column “RD 1”: .20
Maximum density
1 du/acre
§ 20.04.040 · code text
Table row “Density, Maximum”, column “RD 1”: 1 du/acre

Other Chino zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Chino's RD 1 zone?

35 feet — Chino Municipal Code § 20.04.040.

What is the maximum number of stories in Chino's RD 1 zone?

2-1/2 stories — Chino Municipal Code § 20.04.040.

What is the minimum front setback in Chino's RD 1 zone?

25 feet (add five feet along primary and secondary arterial streets) — Chino Municipal Code § 20.04.040.

What is the minimum side setback in Chino's RD 1 zone?

10 feet — Chino Municipal Code § 20.04.040.

What is the minimum rear setback in Chino's RD 1 zone?

25 feet (add five feet along primary and secondary arterial streets) — Chino Municipal Code § 20.04.040.

General information, not legal advice.

Ask about a Chino property in RD 1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Chino