Local zoning · Camarillo
Camarillo — Development Standards
Development Standards under the Camarillo local zoning and planning code, with the controlling citations.
Last reviewed: July 1, 2026
Overview
This page synthesizes the City of Camarillo's local zoning development standards (setbacks, height, lot coverage, density and related rules) as written in Title 19 (Zoning). It is a practical, Camarillo-specific reference keyed to the controlling code sections so applicants and reviewers can find the precise rule quickly. For context on related topics you’ll see links to the city's zoning and process pages (examples: Camarillo Zoning, Camarillo Land Use, and the city's guidance on parking, design review, overlay districts, ADUs, and the statewide California Building Standards Code.
STAY GROUNDED — every numeric standard below is tied to the specific local code section cited after the rule (§ XX.XX.XXX) and the source file reference from the retrieved ordinance.
District-by-district development-standard reference
Notes on how to read these subsections:
- "Purpose / Typical uses" is a one-line orienting summary (not the full use table).
- "Key dimensional standards" lists the most decision-relevant controls (setbacks, height, lot coverage, density, minimum lot area/width as applicable).
- "Where it applies / practical notes" states geographic or procedural points and flags where the code delegates decisions to the Planning Commission or Director.
R-1 — One-Family Residential (Chapter 19.14)
Purpose / Typical uses: single-family detached homes and customary accessory uses; site design review is administrative.
Key dimensional standards:
- Minimum lot area / width: 7,000 sq ft / 70 ft for base R-1; subzones R-1-8, R-1-9, R-1-10, R-1-13, R-1-20, R-1-30, etc. set larger minima (§ 19.14.050) .
- Front setback: 20 ft from right-of-way (minimum) (§ 19.14.070) .
- Side setback: 5 ft for one-story; 10 ft for two-story (§ 19.14.070) .
- Rear setback: 20 ft (grade limit exceptions described) (§ 19.14.070) .
- Garages: garages must be set back 20 ft from any property line where vehicle access is provided (§ 19.14.080) .
Where it applies / practical notes: R-1 is the default single-family district; the city provides subzone suffixes to control lot area/width (see § 19.06.010 for subzone rules) .
RPD — Residential Planned Development (Chapter 19.16)
Purpose / Typical uses: planned residential projects that use modern site planning; densities set by subzone (RPD-XU).
Key dimensional standards:
- Density: subzone suffix indicates max units/acre (e.g., RPD-8U, RPD-20U); RPD without suffix may go to 30 units/acre via planned development process consistent with the General Plan (§ 19.16.070) .
- Front setback: 20 ft when unit fronts on ROW (unless alternate approved by RPD permit) (§ 19.16.080) .
- Side setback: 10 ft street side for one-story; interior side generally 5 ft (higher for two-story or cluster variations) (§ 19.16.080) .
- Rear setback: 20 ft with grade limit (exceptions where common open space provided) (§ 19.16.080) .
- Max building height: 25 ft unless RPD permit authorizes more (§ 19.16.090) .
- Building coverage: 40% for RPD-4 or less; 50% for larger RPDs (recreation buildings may be excluded) (§ 19.16.100) .
Where it applies / practical notes: many RPD dimensions are adjustable through the RPD permit; review is by the Planning Commission for departures from R-1 standards (§ 19.16.010) .
R-E — Rural Exclusive Residential (Chapter 19.12)
Purpose / Typical uses: large-lot rural residential and agricultural-compatible residential.
Key dimensional standards:
- Building height: 35 ft (with exceptions / CUP) (§ 19.12.110) .
- Accessory buildings: may project into yards under quantified limits; detached accessory buildings limited in rear yard coverage and height 15 ft for accessory structures (§ 19.12.140) .
Where it applies / practical notes: utilities must be placed underground in R-E (§ 19.12.120) .
R-C — Recreation Commercial (Chapter 19.20)
Purpose / Typical uses: larger commercial/recreational sites (e.g., resorts, country clubs, large recreational facilities).
Key dimensional standards:
- Minimum lot area: 1 acre; width typically 150 ft (170 ft for corner lots) (§ 19.20.060) .
- Building height: 45 ft (§ 19.20.070) .
- Front setback: 30 ft (or greater if future dedication required); rear 20–50 ft depending on adjacency to R zones (§ 19.20.080) .
- Maximum coverage: ground floor area not to exceed 50% of site (§ 19.20.090) .
Where it applies / practical notes: where R-C abuts an R zone, larger side/rear setbacks (up to 50 ft) and screening walls are required (§ 19.20.080–19.20.110) .
M‑1 — Light Manufacturing (Chapter 19.30)
Purpose / Typical uses: light industrial and compatible commercial uses; performance standards apply.
Key dimensional standards:
- Minimum lot area: 20,000 sq ft; frontage typically 100 ft and depth 200 ft (§ 19.30.070–19.30.080) .
- Building height: 40 ft (CUP may authorize higher) (§ 19.30.090) .
- Lot coverage: 60% maximum roofed coverage (§ 19.30.100) .
- Setbacks: Front: 20–50 ft (commission determines exact within range); side yard adjacent to public road 20 ft; where adjacent to residential, a transition setback equal to 1.5 ft per vertical foot of building height applies (to a max of 50 ft) (§ 19.30.110) .
Where it applies / practical notes: rooftop HVAC and architectural screening parapets are excluded from height calculations (see § 19.30.090) .
M‑2 — Heavy Manufacturing (Chapter 19.32)
Purpose / Typical uses: heavier industrial uses with larger parcel requirements.
Key dimensional standards:
- Minimum parcel area: 40,000 sq ft (except existing smaller legal parcels) (§ 19.32.060) .
- Building height: 40 ft (unless CUP) (§ 19.32.080) .
- Lot coverage: 60% (§ 19.32.090) .
- Setbacks: Front minimum 20 ft; side and rear rules include landscaped buffer and the same 1.5 ft per vertical foot transition where abutting residential (§ 19.32.100) .
Where it applies / practical notes: landscape area minimums and irrigation requirements are explicit (e.g., 10% landscaping) (§ 19.32.130) .
CCM — Camarillo Commons Mixed‑Use (Chapter 19.21)
Purpose / Typical uses: mixed-use center pattern (integrated commercial/residential).
Key dimensional standards:
- Minimum zone area: 40,000 sq ft; min width 150 ft; min depth 200 ft (§ 19.21.070) .
- Minimum yard requirements: planning commission sets yard requirements within defined minimums: front 15–20 ft, no required interior side yards (but side yard adjacent to residential 20 ft), no required rear yard except where adjacent to a public street (§ 19.21.080) .
- Building coverage: set by planned development or conditional use permit (§ 19.21.120) .
Where it applies / practical notes: CCM standards are applied via an integrated planned development review; parking and loading reference Chapters 19.44 and 19.46 (§ 19.21.090–19.21.095) .
A‑E — Agricultural Exclusive (Chapter 19.10)
Purpose / Typical uses: larger agricultural parcels and uses.
Key dimensional standards:
- Minimum acreage: 10 acres (or other suffix-specified minimum) (§ 19.10.050–19.10.060) .
- Setbacks: Front / Side / Rear: 50 ft minimum for habitations (§ 19.10.070) .
- Building height (O-S counterpart): open-space zones have 25 ft caps where applicable (§ 19.34.050) .
Where it applies / practical notes: agricultural uses have performance standards (hazardous materials, animal setbacks) and separate rules for accessory structures (§ 19.10.070 and Chapter 19.54) .
Quick reference table — most decision-relevant items
| Topic / District | Key numeric standard | Code Reference |
|---|---|---|
| R-1 front setback | 20 ft | § 19.14.070 |
| R-1 side / rear | 5 ft / 20 ft (one-story side / rear) | § 19.14.070 |
| RPD building height | 25 ft (unless increased by permit) | § 19.16.090 |
| RPD density mechanics | Subzone suffix indicates units/acre (e.g., RPD-8U) | § 19.16.070 |
| M-1 / M-2 height | 40 ft (typical; CUP may allow higher) | §§ 19.30.090, 19.32.080 |
| M-1 / M-2 coverage | 60% lot coverage | §§ 19.30.100, 19.32.090 |
| CCM front yard minimum | 15 ft (min); planning commission sets final within 15–20 ft | § 19.21.080 |
| ADU side/rear setback minimum (local rules aligned with state) | 4 ft side/rear minimum for qualifying ADUs; other ADU size/height limits per local chapter and state law | § 19.14.170.D and ADU provisions (§ 19.14.170) |
| Minimum lot-area table (R-1 subzones) | R-1: 7,000 sq ft; R-1-8: 8,000 sq ft; etc. | § 19.14.050 |
| Parking reference | See Chapter 19.44 (parking schedule; exemptions near Metrolink) | § 19.21.090 and cross‑refs in each zone (ex.: § 19.30.090 and others) |
Notes: The code uses percent lot coverage rather than a ubiquitous citywide FAR (floor-area ratio) number for most zones; a numeric FAR is not consistently specified in the retrieved materials (see "Information Gaps" below).
Checklist — what an applicant must satisfy (local code highlights)
- Confirm zoning district and subzone on the official map and the applicable zone chapter (Title 19); review zone uses and development standards (§ 19.06.010) .
- Provide evidence the parcel is a legal lot at application (§ 19.08.030; urban lot split rules where applicable) .
- Meet the district setbacks, height and coverage standards cited for the district (e.g., § 19.14.070 for R-1, § 19.16.080–100 for RPD, § 19.30.090–110 for M-1) .
- Provide required landscaping / screening per district (examples: 10% landscaping for M-2 § 19.32.130) .
- Demonstrate compliance with parking rules (Chapter 19.44) and any local parking exemptions (e.g., near Metrolink station) — see the city's parking page and § 19.21.080–19.21.090 where CCM references parking rules .
- If proposing ADUs, apply ADU sizing, setback and height rules in Chapter 19.14 and confirm exceptions that implement state ADU law (§ 19.14.170 and related ADU subsections) — see the city’s ADU page for process details (/us/california/camarillo/adu) (§ 19.14.170) .
- If development triggers design review or planned development review, include architectural plans, elevations and material samples for design review as required (see Camarillo Design Review) and the plan submittal requirements noted in the zone chapter (§ 19.14.040 and zone-specific plan review provisions) .
- Verify special overlay or project-area rules (historic, floodplain, or other overlay districts — see Camarillo Overlay Districts and the zoning map) .
- Prepare landscape plans and irrigation specs consistent with the city’s landscaping guidelines (§ 19.38.060) .
Risks & Ambiguities
| Issue | Why it matters | What to verify |
|---|---|---|
| Absence of a single citywide FAR value | Some applicants search for an FAR; Camarillo’s code chiefly uses lot coverage or subzone-based density, not a universal FAR | Confirm whether a site-specific planned development or specific plan uses an FAR — the code text does not consistently set a citywide FAR (Not found in retrieved materials) |
| Commission discretion in CCM / PDs | For CCM and many PDs the Planning Commission sets final yard setbacks and other dimensional parameters within ranges — this affects predictability | Identify whether your site is in a PD/CCM area that requires a planned development permit and ask the planner for typical approvals; cite § 19.21.080 and § 19.16.050 |
| ADU-state law interplay | State ADU law limits local ability to block small ADUs (e.g., 800 sq ft / 4-ft setbacks); local ADU rules in § 19.14.170 reflect that but may include local conditions | For ADUs, confirm which local ADU provisions invoke or implement state ADU law and whether the property is in a historic/overlay district (see § 19.14.170) |
| Varied landscape / irrigation standards | Industrial or large commercial projects require specific % landscape area and irrigation plans (e.g., 10% for M-2) — affect usable buildable area | Verify required landscape % and plan approval timing in § 19.32.130 and local Landscape & Irrigation Guidelines (§ 19.38.060) |
| Lot-width / subzone averaging rules | Subzone “Av.” averaging rules can change minimums — this alters what parcels can be legally developed | If relying on an "average" subzone calculation, confirm the planning commission findings required and how frontage reductions are calculated (§ 19.06.010, § 19.14.050) |
Plain-English summary
Camarillo’s zoning (Title 19) controls how big and tall you can build by district: single-family R-1 lots have 7,000-sq-ft base lots with 20-ft front setbacks and 5–10 ft side yards, planned developments (RPD) and mixed-use areas (CCM) let the City approve alternatives within set ranges, and industrial zones ( M‑1, M‑2) typically limit height to 40 ft and coverage to 60%; accessory dwelling units follow the local ADU chapter (with state-law overlays) — always verify the exact § in Title 19 for your parcel before assuming numbers. See the governing code sections cited in each district subsection above for the precise rule that applies to your site (§ 19.02.010 et seq.) .
Information Gaps
- Specific numeric FAR (floor-area ratio) values for most zones: Not found in retrieved materials — the code consistently uses percent lot coverage or subzone density instead (see M‑1 / M‑2 coverage rules) .
- Where a parcel lies in a specialized specific‑plan or recently adopted overlay that alters the base Title 19 numbers: that must be checked on the official zoning map and any overlay chapter (overlay content was not included in the retrieved file extract; see city overlay map) .
- Any numerical updates adopted after the print export of the provided Title 19 extract (always verify the City's online code / planner for post-adoption amendments). Verify with the jurisdiction.
Source References
- Camarillo Title 19 — Zoning (print export): general purpose and definitions; see § 19.02.010 and Chapter headings for Title 19 (Title 19 general) .
- R-1 zone standards: § 19.14.050 (lot area / width table), § 19.14.070 (minimum yards), § 19.14.080 (garages) .
- RPD standards: § 19.16.070 (density), § 19.16.080 (yards), § 19.16.090 (height), § 19.16.100 (coverage) .
- R-E standards (rural exclusive): § 19.12.110 (height), § 19.12.140 (accessory buildings) .
- R-C standards: § 19.20.060–090 (lot area, height, setbacks, coverage) .
- M-1 (light manufacturing): § 19.30.070–110 (lot area, height, coverage, setbacks) .
- M-2 (heavy manufacturing): § 19.32.060–130 (parcel area, height, coverage, setbacks, landscaping) .
- CCM (Camarillo Commons Mixed‑Use): § 19.21.070–120 (lot area, yard minimums, building coverage set by PD) .
- ADU local rules (size, setbacks, height referencing state ADU law): § 19.14.170 (ADU standards), local ADU subsections and cross-references to state law (ADU materials in the code extract) .
- Subzone rules and minimum lot-width table: § 19.06.010 and the subzone suffix table (§ 19.06.010) .
- Landscaping / irrigation guidance reference: § 19.32.130 (landscaping standards for M‑2), § 19.38.060 (landscape/irrigation guidelines) .
Sources
Retrieved passages
- Camarillo Zoning Code (§ 2) High relevance
- Camarillo Zoning Code (§ 20) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- CBC § 66314 (§ 66314) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- CFC § 21155 (Section 21155) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- Camarillo Zoning Code (§ 3) High relevance
- Camarillo Zoning Code (section is) High relevance
- Camarillo Zoning Code (§ 1) High relevance
- Camarillo Zoning Code (§ 19) High relevance
- Camarillo Zoning Code (§ 4) Medium relevance
- Camarillo Zoning Code (§ 3) Medium relevance
- Camarillo Zoning Code (Chapter 19.62) Medium relevance
- Camarillo Zoning Code (Title 19) Medium relevance
- Camarillo Zoning Code (§ 2) Medium relevance
Cited sections
- Camarillo Title 19 — Zoning (print export): general purpose and definitions; see § **19.02.010** and Chapter headings for Title 19 (Title 19 general) . (Title 19)
- **R-1** zone standards: § **19.14.050** (lot area / width table), § **19.14.070** (minimum yards), § **19.14.080** (garages) .
- **RPD** standards: § **19.16.070** (density), § **19.16.080** (yards), § **19.16.090** (height), § **19.16.100** (coverage) .
- **R-E** standards (rural exclusive): § **19.12.110** (height), § **19.12.140** (accessory buildings) .
- **R-C** standards: § **19.20.060–090** (lot area, height, setbacks, coverage) .
- **M-1** (light manufacturing): § **19.30.070–110** (lot area, height, coverage, setbacks) .
- **M-2** (heavy manufacturing): § **19.32.060–130** (parcel area, height, coverage, setbacks, landscaping) .
- **CCM** (Camarillo Commons Mixed‑Use): § **19.21.070–120** (lot area, yard minimums, building coverage set by PD) .
- **ADU** local rules (size, setbacks, height referencing state ADU law): § **19.14.170** (ADU standards), local ADU subsections and cross-references to state law (ADU materials in the code extract) .
- Subzone rules and minimum lot-width table: § **19.06.010** and the subzone suffix table (§ **19.06.010**) .
- Landscaping / irrigation guidance reference: § **19.32.130** (landscaping standards for M‑2), § **19.38.060** (landscape/irrigation guidelines) .
- Camarillo_ZoningCode.md
Frequently asked questions
What can I build on an R-1 lot in Camarillo?
You may build the uses allowed in the R-1 district (single-family dwellings and customary accessory uses) subject to dimensional limits for that subzone: minimum lot area/width per § 19.14.050, front/side/rear yards as in § 19.14.070, and garage setback rules in § 19.14.080. Confirm your lot’s R-1 subzone (R-1, R-1-8, R-1-10, etc.) on the zoning map because minimum lot area and frontage change by suffix (§ 19.14.050) .
What are Camarillo setback requirements for single-family homes?
Base R-1 setbacks are: front 20 ft, side 5 ft one-story / 10 ft two-story, rear 20 ft, per § 19.14.070. Planned developments (RPD) and some mixed-use areas allow alternate setbacks via permit; see § 19.16.080 for RPD and § 19.21.080 for CCM minimum ranges and commission discretion (§ 19.14.070, § 19.16.080, § 19.21.080) .
Do Camarillo zones use FAR or lot coverage?
Camarillo’s Title 19 typically specifies percent lot coverage (for example 60% in M-1/M-2 and 40–50% for RPDs) rather than a single citywide FAR; a citywide numeric FAR is not found in retrieved materials. Check the zone’s chapter for coverage limits (e.g., § 19.30.100, § 19.32.090, § 19.16.100) .
How high can I build in Camarillo?
Height limits are zone-specific. Typical caps include R-E 35 ft (§ 19.12.110), RPD 25 ft (unless increased by permit) (§ 19.16.090), and M‑1/M‑2 40 ft (unless CUP) (§ 19.30.090, § 19.32.080). Planned developments and conditional use permits can allow departures where the code authorizes them (§ 19.12.110, § 19.16.090, § 19.30.090) .
Do I need to meet special landscaping or screening when next to residential?
Yes. Where commercial/industrial zones abut residential zones the code typically requires expanded setbacks, landscaped buffers and often a six‑foot masonry screen wall (for example § 19.30.110 and § 19.32.100 include transition setbacks and screening; § 19.32.130 specifies minimum landscape area in M‑2) .
What does Camarillo require for ADU setbacks and size?
Camarillo’s ADU chapter requires ADUs to follow the underlying zone’s development standards but implements state ADU provisions: 4‑ft side/rear setbacks are acknowledged as a minimum for qualifying ADUs and local size/height rules appear in the ADU chapter (e.g., detached ADU height caps and maximum unit sizes in § 19.14.170) — see § 19.14.170 and cross-references to state ADU law for exact application and exceptions (§ 19.14.170) .
Where are parking requirements specified and are there exemptions?
Parking standards are in Chapter 19.44; certain projects (e.g., developments within 1/2 mile of the Camarillo Metrolink station) may be exempted from minimum parking requirements as described in zone-specific provisions (see CCM / by‑site exemptions referenced in § 19.21.080–19.21.090) .
If my project is in CCM, who decides final setbacks?
The Planning Commission establishes yard requirements within the code’s minimums for the CCM zone; the code sets floor ranges (for example front yards 15–20 ft) and authorizes the Commission to set exact setbacks as part of the planned development review (§ 19.21.080) .
Are lot-width minima adjustable for varied topography or design?
Yes. The code allows the Planning Commission to modify minimum lot widths and to create “average” subzones (the “Av.” suffix) subject to findings and limits in § 19.06.010 and the subzone tables (§ 19.06.010, § 19.14.050) .
What section says the city’s zoning ordinance exists and how it’s structured?
Title 19’s purpose and scope are stated in § 19.02.010, which explains the Title consolidates zoning rules for height, yards, lot area, density and other controls (Title 19 is the official zoning ordinance) (§ 19.02.010) .
More in Camarillo code
Ask about any Camarillo property
Get a cited, plain-English answer on Camarillo zoning, setbacks, FAR, ADUs and permits — for any address.
Start Free Trial