Skip to content

Brisbane · Zoning · R-2

Brisbane R-2 zoning: height, setbacks and lot size

In Brisbane's R-2 zone, buildings can be up to 36 ft tall, the front setback is 15 ft and the minimum lot size is 5,000 sq ft (Brisbane code, read October 2026).

Key points

  • Maximum building height: 36 ft
  • Minimum front setback: 15 ft
  • Minimum side setback: 5 ft (a lot under 50 ft wide may reduce it to 10% of lot width, not below 3 ft or the Building Code minimum)
  • Minimum rear setback: 10 ft
  • Minimum lot size: 5,000 sq ft
  • Maximum lot coverage: 50% (under state law, does not preclude a 3 to 10 unit housing project if needed to reach the maximum floor area ratio)
  • Maximum floor area ratio (FAR): 0.72 (single-family dwellings, duplexes and two-unit dwelling groups)
  • Maximum density: 1 unit per 2,500 sq ft (a lot of 4,950 sq ft or more is conforming for 2 units; state law protects 3 units on an existing lot of record)

R-2 (R-2 Residential District) is a zoning district in Brisbane. Every value below was read from the Brisbane Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
36 ft
§ 17.08.040 · code text
Except as otherwise provided in paragraph 2 of this subsection G and in Section 17.32.060, the maximum height of any structure shall be thirty-six (36) feet.
Minimum front setback
15 ft
§ 17.08.040 · code text
Front Setback: Fifteen (15) feet, with the following exceptions:
Minimum side setback
5 ft
Applies: a lot under 50 ft wide may reduce it to 10% of lot width, not below 3 ft or the Building Code minimum
§ 17.08.040 · code text
Side Setback: Five (5) feet, with the exception that a lot having a width of less than fifty (50) feet may have a side setback reduced to ten percent (10%) of the lot width, but in no event less than three (3) feet or the minimum setback required by the Uniform Building Code, whichever is greater.
Minimum rear setback
10 ft
§ 17.08.040 · code text
Rear Setback: Ten (10) feet.
Minimum lot size
5,000 sq ft
§ 17.08.040 · code text
The minimum area of any lot shall be five thousand (5,000) square feet, except as otherwise provided in subsection B of this Section 17.08.040.
Maximum lot coverage
50%
Applies: under state law, does not preclude a 3 to 10 unit housing project if needed to reach the maximum floor area ratio
§ 17.08.040 · code text
The maximum coverage by all structures on any lot shall be fifty percent (50%); except that, pursuant to state law, the maximum lot coverage shall not preclude a housing development project of at least three (3) units but not more than ten (10) units, if exceeding the maximum coverage is required to allow for development up to the floor area ratio maximum, as that ratio is determined by the building official; in such instance, no variance shall be required in order for the lot to exceed the maximum coverage.
Maximum floor area ratio (FAR)
0.72
Applies: single-family dwellings, duplexes and two-unit dwelling groups
§ 17.08.040 · code text
Single family dwellings, duplexes and two-unit dwelling groups shall have a maximum floor area ratio of 0.72, with the following exceptions:
Maximum density
1 unit per 2,500 sq ft
Applies: a lot of 4,950 sq ft or more is conforming for 2 units; state law protects 3 units on an existing lot of record
§ 17.08.040 · code text
The minimum lot area for each dwelling unit on the site shall be two thousand five hundred (2,500) square feet; provided, however, a lot having an area of four thousand nine hundred fifty (4,950) square feet or greater shall be considered conforming for a development density of two (2) units, and further provided that pursuant to state law, a housing development project of three (3) units proposed on an existing legal lot of record shall not be denied solely on the basis that the lot area of that lot does not meet the minimum lot area for each dwelling unit.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-2:

  • Maximum building height: 20 ft — for a distance of 15 ft from the front lot line, measured from finish grade § 17.08.040
  • Maximum building height: 15 ft — Garages and carports within 15 ft of the front lot line, when permitted by Section 17.32.070; measured above the center of the adjacent street § 17.08.040
  • Minimum front setback: 10 ft — lot has a slope of fifteen percent (15%) or greater § 17.08.040
  • Minimum front setback: average distance of front outside wall, if less than 15 ft — 50% or more of lots of record in a block have been improved with single-family dwellings § 17.08.040
  • Minimum front setback: 10 ft — garages or carports; except where a lesser distance is determined by the city engineer to be safe in terms of pedestrian and vehicular traffic § 17.08.040
  • Minimum side setback: 10% of lot width, min 3 ft or Uniform Building Code minimum, whichever is greater — lot width is less than 50 ft § 17.08.040
  • Minimum side setback: 10 ft — garages or carports accessed from a street or alley along that side of the lot; except where a lesser distance is determined by the city engineer to be safe in terms of pedestrian and vehicular traffic § 17.08.040
  • Maximum floor area ratio (FAR): 1.0 — multiple-family development of three to seven units § 17.08.040
  • Maximum floor area ratio (FAR): 1.25 — multiple-family development of eight to ten units § 17.08.040

Not on this page

We did not find a general stories limit for R-2 in the zoning tables we read. The code may still set one elsewhere — check the Brisbane Municipal Code.

Other Brisbane zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Brisbane's R-2 zone?

36 ft — Brisbane Municipal Code § 17.08.040.

What is the minimum front setback in Brisbane's R-2 zone?

15 ft — Brisbane Municipal Code § 17.08.040.

What is the minimum side setback in Brisbane's R-2 zone?

5 ft (a lot under 50 ft wide may reduce it to 10% of lot width, not below 3 ft or the Building Code minimum) — Brisbane Municipal Code § 17.08.040.

What is the minimum rear setback in Brisbane's R-2 zone?

10 ft — Brisbane Municipal Code § 17.08.040.

What is the minimum lot size in Brisbane's R-2 zone?

5,000 sq ft — Brisbane Municipal Code § 17.08.040.

General information, not legal advice.

Ask about a Brisbane property in R-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Brisbane