Brentwood · Zoning · IC
Brentwood IC zoning: height, setbacks and lot size
In Brentwood's IC zone, generally buildings can be up to 30 ft (2 stories) tall, the front setback is 10 ft and the minimum lot size is 20,000 sq ft, with the conditions listed below (Brentwood code, read October 2026).
Key points
- Maximum building height: 30 ft (Where the zone does not abut a residential zone)
- Maximum number of stories: 2 stories (Where the zone does not abut a residential zone)
- Minimum front setback: 10 ft (where a residentially zoned parcel is in the same block: 75% of that residential setback, but not less than 10 ft)
- Minimum side setback: None required (Unless residentially zoned property abuts the IC zone)
- Minimum lot size: 20,000 sq ft
IC (Industrial/Commercial) is a zoning district in Brentwood. Every value below was read from the Brentwood Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in IC
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 30 ft Applies: Where the zone does not abut a residential zone § 17.310.004 · code textIf the IC zone does not abut a residential zone, the maximum permitted height shall be two stories not to exceed thirty feet, |
|---|---|
| Maximum number of stories | 2 stories Applies: Where the zone does not abut a residential zone § 17.310.004 · code textIf the IC zone does not abut a residential zone, the maximum permitted height shall be two stories not to exceed thirty feet, |
| Minimum front setback | 10 ft Applies: where a residentially zoned parcel is in the same block: 75% of that residential setback, but not less than 10 ft § 17.310.004 · code textMinimum street frontage yard: ten feet. Except where there is a residentially zoned parcel within the same block, the minimum setback shall be seventy-five percent of the minimum setback for the residential zone, but not less than ten feet; |
| Minimum side setback | None required Applies: Unless residentially zoned property abuts the IC zone § 17.310.004 · code textMinimum nonstreet frontage yard: none except where residentially zoned property is abutting the IC zone, the minimum yard shall be ten feet; |
| Minimum lot size | 20,000 sq ft § 17.310.004 · code textMinimum lot area: twenty thousand square feet, except the minimum lot size shall not apply under the following circumstances; |
When a different number applies
The code sets other values for particular lots, buildings or locations in IC:
- Maximum building height: 20 ft — IC zone abuts any residential zone § 17.310.004
- Maximum number of stories: 1 story — IC zone abuts any residential zone § 17.310.004
- Minimum front setback: 75% of the minimum setback for the residential zone, but not less than 10 ft — There is a residentially zoned parcel within the same block § 17.310.004
- Minimum side setback: 10 ft — Residentially zoned property is abutting the IC zone § 17.310.004
Not on this page
We did not find a general rear setback, lot coverage, FAR, density limit for IC in the zoning tables we read. The code may still set one elsewhere — check the Brentwood Municipal Code.
Other Brentwood zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Brentwood's IC zone?
30 ft (where the zone does not abut a residential zone) — Brentwood Municipal Code § 17.310.004.
What is the maximum number of stories in Brentwood's IC zone?
2 stories (where the zone does not abut a residential zone) — Brentwood Municipal Code § 17.310.004.
What is the minimum front setback in Brentwood's IC zone?
10 ft (where a residentially zoned parcel is in the same block: 75% of that residential setback, but not less than 10 ft) — Brentwood Municipal Code § 17.310.004.
What is the minimum side setback in Brentwood's IC zone?
None required (unless residentially zoned property abuts the IC zone) — Brentwood Municipal Code § 17.310.004.
What is the minimum lot size in Brentwood's IC zone?
20,000 sq ft — Brentwood Municipal Code § 17.310.004.
General information, not legal advice.
Ask about a Brentwood property in IC
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question