Skip to content

Arvin · Zoning · C-2

Arvin C-2 zoning: height, setbacks and lot size

In Arvin's C-2 zone, generally buildings can be up to 75 ft (6 stories) tall and the front setback is 40 ft from street centerline, with the conditions listed below (Arvin code, read October 2026).

Key points

  • Maximum building height: 75 ft (taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line)
  • Maximum number of stories: 6 stories (taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line)
  • Minimum front setback: 40 ft from street centerline (along a secondary highway 45 ft from centerline, along a major highway 55 ft; )
  • Minimum side setback: None required (10 ft when the side line abuts a street or residential zone; 20 ft when it abuts an industrial zone)
  • Minimum rear setback: None required (10 ft when the rear line abuts a street or residential zone; 20 ft when it abuts an industrial zone)

C-2 (GENERAL COMMERCIAL ZONE) is a zoning district in Arvin. Every value below was read from the Arvin Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
Applies: taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line
§ 17.26.030 · code text
The maximum height for buildings in the C-2 zone shall be six (6) stories and not to exceed seventy-five (75) feet unless the building sets back from each street, alley and lot line at least one (1) foot for each three (3) feet of height above six (6) stories or seventy-five (75) feet.
Maximum number of stories
6 stories
Applies: taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line
§ 17.26.030 · code text
The maximum height for buildings in the C-2 zone shall be six (6) stories and not to exceed seventy-five (75) feet unless the building sets back from each street, alley and lot line at least one (1) foot for each three (3) feet of height above six (6) stories or seventy-five (75) feet.
Minimum front setback
40 ft from street centerline
Applies: along a secondary highway 45 ft from centerline, along a major highway 55 ft;
§ 17.26.040 · code text
In the C-2 zone, all buildings shall be located not nearer than forty (40) feet from the centerline of a street; provided, however, that along any secondary highway, as designated by the city's highway plan, a minimum setback of forty-five (45) feet from the centerline of the highway shall be required, and along any major highway, as designated by the city's highway plan, minimum setback of fifty-five (55) feet from the centerline of the highway shall be required.
Minimum side setback
None required
Applies: 10 ft when the side line abuts a street or residential zone; 20 ft when it abuts an industrial zone
§ 17.26.050 · code text
In the C-2 zone, a side yard setback is not required, except that a minimum side yard of ten (10) feet shall be provided when the side property line abuts a street or a residential zone; and a minimum side yard setback of twenty (20) feet, when the side property line abuts an industrial zone.
Minimum rear setback
None required
Applies: 10 ft when the rear line abuts a street or residential zone; 20 ft when it abuts an industrial zone
§ 17.26.060 · code text
In the C-2 zone, a rear yard setback is not required, except that a minimum rear yard of ten (10) feet shall be provided when the rear property line abuts a street or a residential zone; and a minimum rear yard of twenty (20) feet when the rear property line abuts an industrial zone.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-2:

  • Maximum building height: 135 ft — Height above six stories or 75 feet permitted with required additional setback; absolute maximum § 17.26.030
  • Maximum number of stories: 10 stories — Height above six stories or 75 feet permitted with required additional setback; absolute maximum § 17.26.030
  • Minimum front setback: 45 ft from highway centerline — Along any secondary highway designated by the city's highway plan § 17.26.040
  • Minimum front setback: 55 ft from highway centerline — Along any major highway designated by the city's highway plan § 17.26.040
  • Minimum front setback: 72 ft — From the centerline of Bear Mountain Boulevard (State Route 223) § 17.26.040
  • Minimum side setback: 10 ft — When the side property line abuts a street or a residential zone § 17.26.050
  • Minimum side setback: 20 ft — When the side property line abuts an industrial zone § 17.26.050
  • Minimum rear setback: 10 ft — When the rear property line abuts a street or a residential zone § 17.26.060
  • Minimum rear setback: 20 ft — When the rear property line abuts an industrial zone § 17.26.060
  • Minimum rear setback: 0 ft — When there is an existing public dedicated and accepted alley abutting the rear property line § 17.26.060

Not on this page

We did not find a general lot size, lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the Arvin Municipal Code.

Other Arvin zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Arvin's C-2 zone?

75 ft (taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line) — Arvin Municipal Code § 17.26.030.

What is the maximum number of stories in Arvin's C-2 zone?

6 stories (taller only if the building sets back 1 ft per 3 ft of height above 6 stories or 75 ft, from every lot line) — Arvin Municipal Code § 17.26.030.

What is the minimum front setback in Arvin's C-2 zone?

40 ft from street centerline (along a secondary highway 45 ft from centerline, along a major highway 55 ft; ) — Arvin Municipal Code § 17.26.040.

What is the minimum side setback in Arvin's C-2 zone?

None required (10 ft when the side line abuts a street or residential zone; 20 ft when it abuts an industrial zone) — Arvin Municipal Code § 17.26.050.

What is the minimum rear setback in Arvin's C-2 zone?

None required (10 ft when the rear line abuts a street or residential zone; 20 ft when it abuts an industrial zone) — Arvin Municipal Code § 17.26.060.

General information, not legal advice.

Ask about an Arvin property in C-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Arvin