Skip to content

Alhambra · Zoning · AC

Alhambra AC zoning: height, setbacks and lot size

In Alhambra's AC zone, generally buildings can be up to 75 ft (5 stories) tall and the front setback is 0 ft, with the conditions listed below (Alhambra code, read October 2026).

Key points

  • Maximum building height: 75 ft (More than 50 feet from a residential zoning district)
  • Maximum number of stories: 5 stories (More than 50 feet from a residential zoning district)
  • Minimum front setback: 0 ft
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft
  • Maximum floor area ratio (FAR): 2.0

AC is a zoning district in Alhambra. Every value below was read from the Alhambra Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in AC

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
Applies: More than 50 feet from a residential zoning district
§ 23.05.030 · code text
Table row “Maximum building height (feet)”, column “AC”: 40 within 50 feet of a Residential Zoning District, otherwise 75
Maximum number of stories
5 stories
Applies: More than 50 feet from a residential zoning district
§ 23.05.030 · code text
Table row “Maximum number of stories”, column “AC”: 3 within 50 feet of a Residential Zoning District, otherwise 5
Minimum front setback
0 ft
§ 23.05.030 · code text
Table row “Front”, column “AC”: 0
Minimum side setback
0 ft
§ 23.05.030 · code text
Table row “Interior side”, column “AC”: 0, 10 adjacent to a Residential Zoning District
Minimum rear setback
0 ft
§ 23.05.030 · code text
Table row “Rear”, column “AC”: 0, 10 adjacent to a Residential Zoning District
Maximum floor area ratio (FAR)
2.0
§ 23.05.030 · code text
Table row “Maximum floor area ratio (FAR)”, column “AC”: 2.0

When a different number applies

The code sets other values for particular lots, buildings or locations in AC:

  • Maximum building height: 40 ft — within 50 feet of a Residential Zoning District § 23.05.030
  • Maximum number of stories: 3 stories — within 50 feet of a Residential Zoning District § 23.05.030
  • Minimum side setback: 10 ft — adjacent to a Residential Zoning District § 23.05.030
  • Minimum rear setback: 10 ft — adjacent to a Residential Zoning District § 23.05.030

Not on this page

We did not find a general lot size, lot coverage, density limit for AC in the zoning tables we read. The code may still set one elsewhere — check the Alhambra Municipal Code.

Other Alhambra zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Alhambra's AC zone?

75 ft (more than 50 feet from a residential zoning district) — Alhambra Municipal Code § 23.05.030.

What is the maximum number of stories in Alhambra's AC zone?

5 stories (more than 50 feet from a residential zoning district) — Alhambra Municipal Code § 23.05.030.

What is the minimum front setback in Alhambra's AC zone?

0 ft — Alhambra Municipal Code § 23.05.030.

What is the minimum side setback in Alhambra's AC zone?

0 ft — Alhambra Municipal Code § 23.05.030.

What is the minimum rear setback in Alhambra's AC zone?

0 ft — Alhambra Municipal Code § 23.05.030.

General information, not legal advice.

Ask about an Alhambra property in AC

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Alhambra