Santa Ana Municipal Code § 8-2815 Referenced standards (Chapter 44)

Santa Ana Municipal Code · 2026-10 edition · updated 2026-10-04 · Santa Ana

Cite as: Santa Ana Municipal Code § 8-2815 · Text as of 2026-10-04

Sec. 8-2810. - Climatic and geographic design criteria (Table R301.2).

Table R301.2 is revised to read:

TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

Ground Snow Load Wind Design Wind Design Wind Design Wind Design Seismic Design Category f Subject to Damage From Subject to Damage From Subject to Damage From Ice barrier Underlay- ment Required h Flood Hazards g Air Freezing Index i Mean Annual Temp j
Ground Snow Load Speed d (mph) Topo- graphic effects k Special wind region l Wind- borne debris zone m Seismic Design Category f Weathering a Frost line Depth b Termite c Ice barrier Underlay- ment Required h Flood Hazards g Air Freezing Index i Mean Annual Temp j
Zero 95 No No No D 2 or E Negligible 12—24" Very Heavy No NFIP Date: 09/14/1979 Current Map Date: 12/03/2009 0 60

MANUAL J DESIGN CRITERIA n

Elevation Altitude correction factor e Coincident wet bulb Indoor winter design relative humidity Indoor winter design dry-bulb temperature Outdoor winter design dry-bulb temperature Heating temperature difference
115 1.00 69 70 38
Latitude Daily range Summer design gains Indoor summer design relative humidity Indoor summer design dry-bulb temperature Outdoor summer design dry-bulb temperature Cooling temperature difference
34 26 75 88

For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.

a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652.

b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade.

c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage.

d. The jurisdiction shall fill in this part of the table with the wind speed from the ultimate design wind speeds map [Figure R301.2(2)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.

e. The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction.

f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1.

g. The jurisdiction shall fill in this part of the table with: the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); and the title and date of the currently effective Flood Insurance Study or other flood hazard study and maps adopted by the authority having jurisdiction, as amended.

h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO."

i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)."

j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)."

k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

l. In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the windborne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction.

o. The jurisdiction shall fill in this section of the allowable stress design table using the Ground Snow Loads in Figure R301.2(3).

(Ord. No. NS-2810, § 49, 11-15-10; Ord. No. NS-2851, § 36, 11-18-13; Ord. No. NS-2905, § 14, 12-6-16; Ord. No. NS-2981, § 12, 12-17-19; Ord. No. NS-3032, § 10, 12-20-22; Ord. No. NS-3088, § 12, 1-20-26)

Exceptions & meaning →

Sec. 8-2811. - Masonry stem walls (Section R403.1.3).

Section R403.1.3 is amended to read as follows:

In Seismic Design Categories D0, D1 and D2 masonry stem walls without solid grout and vertical reinforcing are not permitted.

Exception: In detached one- and two-family dwellings which are three stories or less in height and constructed with stud bearing walls, isolated plain concrete footings supporting columns or pedestals are permitted.

(Ord. No. NS-2810, § 50, 11-15-10; Ord. No. NS-2851, § 37, 11-18-13)

Exceptions & meaning →

Sec. 8-2812. - Definitions (Section 202).

Section 202 Definitions is hereby revised by adding "Hazardous Fire Area" as follows:

HAZARDOUS FIRE AREA. Includes all areas identified within California Fire Code Section 4906.2 and other areas as determined by the Fire Code Official as presenting a fire hazard due to the presence of combustible vegetation, or the proximity of the property to an area that contains combustible vegetation.

(Ord. No. NS-2851, § 38, 11-18-13)

Exceptions & meaning →

Sec. 8-2813. - Building planning (Chapter 3).

(a) Section R309.6 Fire sprinkler attached garages, and carports with habitable space above is hereby amended by modifying the exception as follows:

Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing carports and/or garages that do not have an automatic fire sprinkler system installed unless a sprinkler system is required in accordance with California Fire Code Section 903.2.8.

(b) Section R313.1 Townhouse automatic fire sprinkler systems is hereby amended by modifying the exception as follows:

Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing townhouses that do not have an automatic fire sprinkler system installed unless a sprinkler system is required in accordance with California Fire Code Section 903.2.8.

(c) Section R313.2 One- and two-family dwellings automatic fire sprinkler systems is hereby amended by modifying the exception as follows:

Exception: An automatic residential fire sprinkler system shall not be required for additions or alterations to existing buildings that are not already provided with an automatic sprinkler system unless a sprinkler system is required in accordance with California Fire Code Section 903.2.8.

(d) Section R313.3.6.2.2 Calculation procedure is hereby revised as follows:

Section R313.3.6.2.2 Calculation procedure. Determination of the required size for water distribution piping shall be in accordance with the following procedure and California Fire Code Section 903.3.5.3.

(e) Section R319 Site Address is hereby revised as follows:

R319 Site Address. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained.

(Ord. No. NS-2851, § 39, 11-18-13)

Exceptions & meaning →

Sec. 8-2814. - Chimneys and fireplaces (Chapter 10).

Section R1001.13 Chimney spark arresters is hereby added as follows:

R1001.13 Chimney spark arresters. All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. Chimneys serving outdoor appliances or fireplaces shall be equipped with a spark arrester. The spark arrester shall meet the requirements of Section 2113.9.2 of the California Building Code.

(Ord. No. NS-2851, § 40, 11-18-13)

Exceptions & meaning →

Sec. 8-2815. - Referenced standards (Chapter 44).

(a) NFPA 13, 2013 Edition, Installation of Sprinkler Systems is hereby amended as follows:

(1) Section 6.8.3 is hereby amended as follows:

6.8.3 Fire department connections (FDC) shall be of an approved type. The FDC shall contain a minimum of two 2 ½" inlets. The location shall be approved and be no more than 150 feet from a public hydrant. The FDC may be located within 150 feet of a private fire hydrant when approved by the fire code official. The size of piping and the number of inlets shall be approved by the fire code official. If acceptable to the water authority, it may be installed on the backflow assembly. Fire department inlet connections shall be painted OSHA safety red. When the fire sprinkler density design requires 500 gpm (including inside hose stream demand) or greater, or a standpipe system is included, four 2 ½" inlets shall be provided.

(2) Section 8.3.3.1 is hereby amended as follows:

8.3.3.1. When fire sprinkler systems are installed in shell buildings of undetermined use (Spec Buildings) other than warehouses (S occupancies), fire sprinklers of the quick-response type shall be used. Use is considered undetermined if a specific tenant/occupant is not identified at the time the fire sprinkler plan is submitted. Sprinklers in light hazard occupancies shall be one of the following:

  1. Quick-response type as defined in 3.6.4.7

  2. Residential sprinklers in accordance with the requirements of 8.4.5

  3. Standard-response sprinklers used for modifications or additions to existing light hazard systems equipped with standard-response sprinklers

  4. Standard-response sprinklers used where individual standard-response sprinklers are replaced in existing light hazard systems

(3) Section 8.17.1.1.1 is hereby added as follows:

8.17.1.1.1 Residential Waterflow Alarms. A local water-flow alarm shall be provided on all sprinkler systems and shall be connected to the building fire alarm or water-flow monitoring system, where provided. Group R occupancies not requiring a fire alarm system by the California Fire Code shall be provided with a minimum of one approved interior alarm device in each unit. Sound levels in all sleeping areas shall be minimum of 15 DBA above the average ambient sound or a minimum of 75 DBA with all intervening doors closed, whichever is greater. Alarms shall be audible within all other living areas within each dwelling unit. When not connected to a fire alarm or water-flow monitoring system, audible devices shall be powered from an uninterruptible circuit (except for over-current protection) serving normally operated appliances in the residence.

(4) Section 11.1.1.2 is hereby added as follows:

11.1.1.2 When fire sprinkler systems are required in buildings of undetermined use other than warehouses, they shall be designed and installed to have a fire sprinkler density of not less than that required for an Ordinary Hazard Group 2 use, with no reduction(s) in density or design area. Warehouse fire sprinkler systems shall be designed to Figure 16.2.1.3.2 (d) curve "G". Use is considered undetermined if a specific tenant/occupant is not identified at the time the sprinkler plan is submitted. Where a subsequent occupancy requires a system with greater capability, it shall be the responsibility of the occupant to upgrade the system to the required density for the new occupancy.

(5) Section 11.2.3.1.1.1 is hereby added as follows:

11.2.3.1.1.1 The available water supply for fire sprinkler system design shall be determined by one of the following methods, as approved by the Fire Code Official:

  1. Subtract the project site elevation from the low water level for the appropriate pressure zone and multiply the result by 0.433;

  2. Use a maximum of 40 psi, if available;

  3. Utilize the Orange County Fire Authority water-flow test form/directions to document a flow test conducted by the local water agency or an approved third party licensed in the State of California.

(6) Section 23.2.1.1 is hereby revised as follows:

Section 23.2.1.1 Where a waterflow test is used for the purposes of system design, the test shall be conducted no more than 6 months prior to working plan submittal unless otherwise approved by the authority having jurisdiction.

(b) NFPA 13R 2013 Edition, Installation of Sprinkler System in Residential Occupancies up to and Including Four Stories in Height is hereby amended as follows:

(1) Section 6.16.1 is hereby revised as follows:

6.16.1 A local water-flow alarms shall be provided on all sprinkler systems and shall be connected to the building fire alarm or water-flow monitoring system where provided. Group R occupancies containing less than the number of stories, dwelling units or occupant load specified in Section 907.2.8 of the 2010 California Fire Code as requiring a fire alarm system shall be provided with a minimum of one approved interior alarm device in each unit. Sound levels in all sleeping areas shall be a minimum of 15 dBA above the average ambient sound or a minimum of 75 dBA with all intervening doors closed, whichever is greater. Alarms shall be audible within all other living areas within each dwelling unit. When not connected to a fire alarm or water-flow monitoring system, audible devices shall be powered from an uninterruptible circuit (except for over-current protection) serving normally operated appliances in the residence.

There shall also be a minimum of one exterior alarm indicating device, listed for outside service and audible from the access roadway that serves that building.

(c) NFPA 13D 2013 Edition, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes is hereby amended as follows:

(1) Section 4.1.3 is hereby added as follows:

4.1.3 Stock of Spare Sprinklers

(2) Section 4.1.3.1 is hereby added as follows:

4.1.3.1. A supply of at least two sprinklers for each type shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be promptly replaced.

(3) Section 4.1.5.2 [4.1.3.2] is hereby added as follows:

4.1.3.2 The sprinklers shall correspond to the types and temperature ratings of the sprinklers in the property.

(4) Section 4.1.3.3 is hereby added as follows:

4.1.3.3 The sprinklers shall be kept in a cabinet located where the temperature to which they are subjected will at no time exceed 100° F (38° C).

(5) Section 4.1.3.4 is hereby added as follows:

4.1.3.4 A special sprinkler wrench shall be provided and kept in the cabinet to be used in the removal and installation of sprinklers. One sprinkler wrench shall be provided for each type of sprinkler installed.

(6) Section 7.1.2 is hereby revised as follows:

7.1.2 The system piping shall not have a separate control valve unless supervised by a central station, or remote station alarm service

(7) Section 7.6 is hereby deleted in its entirety and replaced as follows:

7.6 Alarms. Exterior alarm indicating device shall be listed for outside service and audible from the street from which the house is addressed. Exterior audible devices shall be placed on the front or side of the structure and the location is subject to final approval by the fire code official. Additional interior alarm devices shall be required to provide 55 dBA or 15 dBA above ambient, whichever is greater. Sound levels in all sleeping areas with all intervening doors closed shall be a minimum of 15 dBA above the average ambient sound level but not less than 75 dBA, whichever is greater. Audible devices shall be powered from an uninterruptible circuit (except for over-current protection) serving normally operated appliances in the residence.

Exception:

  1. When an approved water flow monitoring system is installed, interior audible devices may be powered through the fire alarm control panel.

  2. When smoke detectors specified under CBC Section 907.2.11 are used to sound an alarm upon waterflow switch activation.

(Ord. No. NS-2851, § 41, 11-18-13)

Exceptions & meaning →

Sec. 8-2816. - Vehicular gates (Appendix O).

SECTION AO103.3 Vehicular gates or other barriers across required fire apparatus access roads is added as follows:

AO103.3 Vehicular gates or other barriers across required fire apparatus access roads. The installation of gates or other barriers across a required fire apparatus access road shall comply with the requirements set forth in the 2013 California Fire Code Section 503.6.

(Ord. No. NS-2851, § 42, 11-18-13)

Exceptions & meaning →