SEC. 92.0132. PERMIT FEES FOR REPAIR, REPLACEMENT, ALTERATION, OR MODIFICATION.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
(a) No person shall cause or permit any repairs, replacements, alterations, or modifications to any elevator or equipment regulated by this Code unless a permit has first been obtained from the Department.
For the purposes of this section, the term “alteration” shall include any work which entails the installation or replacement of any of the mechanical devices or apparatus specified in Subsection (d) or Notes A, B, C of this section and any alterations, repairs and replacements listed in the California Code of Regulations, Title 8, Section 3000(h). (Amended by Ord. No. 174,861, Eff. 11/14/02, Oper. 11/1/02.)
(b) The Department shall charge and collect the sum of $26.00 for each inspection permit to do any work and the sum of $143.00 per hour or any portion of an hour for the inspection of the work specified in Notes A, B, C of this section and alterations, repairs and replacements listed in the California Code of Regulations, Title 8, Sections 3000(h), 3141.0 and 3141.2, on each particular elevator, escalator or dumbwaiter including lifts or moving walks. No repair, replacement, alteration or
modification permit shall allow any person to alter the type or design of the installation, and in the event that the work is of a nature that would alter the type, design or purpose of the installation, then a permit shall be obtained pursuant to the provisions of LAMC Section 92.0129. (Amended by Ord. No. 185,587, Eff. 7/16/18.)
(c) Application for all such permits shall be made upon forms provided by the Department.
(d) The fee for any repairs, replacements, alterations or modifications for which a permit is required, but for which no fee is provided here, shall be as provided under LAMC Sections 92.0129 or 92.0132(b). (Amended by Ord. No. 185,587, Eff. 7/16/18.)
(e) The fee for field consultations will be $143.00 per hour or any fraction thereof. (Former Subsec. (f) re-lettered (e) and Amended by Ord. No. 180,868, Eff. 10/22/09.)
NOTE A: For the purpose of this section, the following shall be considered alterations for electric elevators:
| 1. Increase in rated load or speed |
|---|
| 2. Increase in dead weight of car |
| 3. Increase or decrease in travel |
| 4. Change in type of operation or control (including modification of fire and emergency operation) |
| 5. Change in size or number of hoisting or counterweight ropes |
| 6. Change in size or type of guide rails |
| 7. Replacement of or change in type of car or counterweight safety |
| 8. Permissive use of freight elevators to transport employees |
| 9. Change in classification from freight to passenger service |
| 10. Change in power supply |
| 11. Replacement of an existing driving machine by a new driving machine |
| 12. Replacement of an existing controller by a new controller |
| 13. Replacement of an existing driving machine brake by a new brake |
| 14. Replacement of hoistway doors |
| 15. Addition or replacement of hoistway door locking devices or car door or gate electric contact |
| 16. Addition of hoistway access switches |
| 17. Addition of top-of-car operating devices |
| 18. Addition of hoistway door and/or car-door or gate operating devices |
| 19. Addition of rope equalizers |
| 20. Addition of auxiliary rope-fastening devices |
| 21. Addition of car-leveling or truck zoning devices |
| 22. Addition of roller guide shoes |
| 23. Replacement of elevator ropes |
- Land Elevator
NOTE B: For the purpose of this section, the following shall be considered alterations for hydro-electric elevators: (Amended by Ord. No. 174,861, Eff. 11/14/02, Oper. 11/1/02.)
Replacement of an existing control valve with a valve of a different type;
Replacement and repair of existing relief and check valves;
Replacement of existing supply piping and fittings;
Replacement of existing tanks;
Replacement of cylinder and/or plunger with a cylinder or plunger of different material, size or design;
Increase of working pressure;
Earthquake restraints.
NOTE C: For the purpose of this section, replacements or additions to elevators, escalators, dumbwaiters, inclined lifts and moving walks and other related devices regulated by this Code beyond those necessary for normal maintenance shall be considered alterations. (Amended by Ord. No. 174,861, Eff. 11/14/02, Oper. 11/1/02.)
SEC. 92.0132.1. FEES FOR ADDITIONAL INSPECTIONS.¶
(Added by Ord. No. 154,596, Eff. 12/7/80.)
(a) Each periodic inspection shall be entitled to a maximum of two inspection trips. (Amended by Ord. No. 171,185, Eff. 7/22/96.)
(b) A fee as specified in LAMC Section 98.0412(b) shall be paid for each additional inspection trip in excess of the two trips allowed in Subsection (a) of this section. (Amended by Ord. No. 185,587, Eff. 7/16/18.)
(c) The fees charged under this section are in addition to any other fees shown in this division, and the payment of the fees required by this section shall not exempt any person from compliance with other provisions of the Code, nor from any penalty prescribed by law.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
- Division 67
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
- Division 94
- Division 95
▸Division 96
Overview- SEC. 91.9602. SCOPE.
- SEC. 91.9603. DEFINITIONS.
- SEC. 91.9604. ANALYSIS AND DESIGN.
- SEC. 91.9605. MATERIALS OF CONSTRUCTION.
- SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9701. TITLE.
- SEC. 91.9702. PURPOSE.
- SEC. 91.9703. SCOPE.
- SEC. 91.9704. DEFINITIONS.
- SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
- SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
- SEC. 91.9707. RECORD MAINTENANCE.
- SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
- SEC. 91.9709. NONCOMPLIANCE FEE.
- SEC. 91.9710. SUBMITTAL FEES.
- SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
- SEC. 91.9712. SEVERABILITY.
- Article 1.2
- Article 1.5
- Article 1.5 — , DIVISION 1
- Article 1.5 — , DIVISION 2
- Article 1.5 — , DIVISION 3
- Article 1.5 — , DIVISION 4
- Article 1.5 — , DIVISION 5
- Article 1.5 — , DIVISION 6
- Article 1.5 — , DIVISION 7
- Article 1.5 — , DIVISION 8
- Article 1.5 — , DIVISION 9
- Article 2
▸Part 2
Overview- SEC. 92.0126. INSPECTION AND INSPECTION FEES.
- SEC. 92.0127. SPECIAL ENFORCEMENT OF PROCEDURES FEES.
- SEC. 92.0128. INVESTIGATION FEE.
- SEC. 92.0129. INSTALLATION PERMIT FEES.
- SEC. 92.0130. FEES FOR PLAN CHECKING.
- SEC. 92.0131. OFF HOURS INSPECTIONS.
- SEC. 92.0132. PERMIT FEES FOR REPAIR, REPLACEMENT, ALTERATION,…
- SEC. 92.0133. APPROVALS.
- SEC. 92.0134. RESPONSIBILITY OF OWNERS, LESSEES, MANAGERS, ETC.
- Part 3
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D