SEC. 91.6705. DEFINITIONS.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
(Amended by Ord. No. 171,175, Eff. 7/25/96.)
For the purpose of this division, certain terms are defined as follows:
CYLINDER GUARD. A ring surrounding the exposed portion of the lock cylinder, or any other device, which is so fastened as to protect the cylinder from wrenching, prying, cutting, or pulling by attack tools. The ring shall be made from steel or brass and shall have a minimum taper of 15 degrees.
DEADLOCKING LATCH. A latch in which the latch bolt is positively held in the projected position by a guard bolt, a plunger or an auxiliary mechanism.
DEADBOLT. A bolt which has no automatic spring action and which is operated by a key cylinder, thumb-turn, or lever, and is held fast when in the projected position.
ENCLOSING PARTITION. A partition extending the full height of the story to the floor or roof above separating tenant spaces.
LATCH. A device for automatically retaining a door, upon its closing, in a closed position.
SECURITY OPENING. An opening in a wall, partition, or roof when such opening occurs in any of the following locations:
In an exterior wall and less than 16 feet above the grade of any adjoining yard, court, passageway, public way, walk, breezeway, patio, planter porch or similar area.
In an exterior wall and less than 16 feet above the surface of any adjoining roof, balcony, landing, stair tread, platform, or similar structure when that surface is accessible to the public or another tenant or when any portion of such surface is itself less than 16 feet above an accessible grade.
In the enclosing partitions of a dwelling unit, private garage, guest room or single-tenant non-residential area.
In a roof when any portion of such roof is less than 16 feet above an accessible grade or surface accessible by another tenant or the public.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
▸Division 67
Overview- SEC. 91.6701. PURPOSE.
- SEC. 91.6702. GENERAL.
- SEC. 91.6703. LIMITATIONS.
- SEC. 91.6704. ALTERNATE SECURITY PROVISIONS.
- SEC. 91.6705. DEFINITIONS.
- SEC. 91.6706. ENTRY VISION.
- SEC. 91.6707. APPURTENANT ACCESS.
- SEC. 91.6708. DOORS – GENERAL.
- SEC. 91.6709. SWINGING DOORS.
- SEC. 91.6710. SLIDING GLASS DOORS.
- SEC. 91.6711. OVERHEAD AND SLIDING DOORS.
- SEC. 91.6712. METAL ACCORDION-GRATE OR GRILLE-TYPE DOORS.
- SEC. 91.6713. GLAZED OPENING – GENERAL.
- SEC. 91.6714. GLAZING.
- SEC. 91.6715. WINDOWS.
- SEC. 91.6716. OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS.
- SEC. 91.6717. TESTS – GENERAL.
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
- Division 94
- Division 95
- Division 96
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D