Los Angeles Municipal Code § 91.2305 General Design Requirements for Lateral Force-Resisting System
Los Angeles Municipal Code · 2026-10 edition · updated 2026-10-27 · Los Angeles
Cite as: Los Angeles Municipal Code § 91.2305 · Text as of 2026-10-27
91.2305.4. Quality of Nails.¶
In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails. (Readopted by Ord. No. 188,797, Eff. 12/31/25.)
91.2305.5. Hold-down Connectors.¶
In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be finger tight and 1/2 turn just prior to covering the wall framing. (Readopted by Ord. No. 188,797, Eff. 12/31/25.)
Continue researching
Los Angeles sources →Los Angeles local, state and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code