Skip to content

Earlier editions: 2026-09

Title 130 — ZONING›Article 2 — ZONES, ALLOWED USES, AND ZONING STANDARDS

El Dorado County Municipal Code § 130.26.060 Development Standards

El Dorado County Municipal Code · 2026-10 edition · updated 2026-10-04 · El Dorado County

Cite as: El Dorado County Municipal Code § 130.26.060 · Text as of 2026-10-04

Sec. 130.26.010 - Zone Established.

The MAP Zone is applied to implement the policies of the Meyers Area Plan by setting forth separate and distinct uses and standards which apply to each of the five areas of the Meyers Community. As noted in the Sections which follow, the allowed uses and development standards may vary for each designated area as a means of implementing the policies of the adopted Meyers Area Plan.

Exceptions & meaning →

Sec. 130.26.020 - Applicability.

The regulations set forth in this Chapter shall apply to the Meyers Area Plan (MAP) Zone. Where applicable, the standards of this Title shall apply. Additionally, the provisions of the Tahoe Regional Planning Agency (TRPA) Code of Ordinances shall apply to all projects within the MAP Zone. Where there is a conflict with the TRPA Code of Ordinances and this Ordinance, the most restrictive standard shall apply.

Exceptions & meaning →

Sec. 130.26.030 - Zone Designations.

In order to differentiate the variable uses and development standards required for each area, the MAP Zone will be designated on the official zone map as follows:

A. MAP-1 Meyers Community Center District (Center)

B. MAP-2 Meyers Industrial District (Ind)

C. MAP-3 Upper Truckee Residential/Tourist District (Res/T)

D. MAP-4 Meyers Recreation District (Rec)

E. MAP-5 Upper Truckee River Corridor District (River)

Exceptions & meaning →

Sec. 130.26.040 - Uses Allowed by Right or by Conditional Use Permit.

A. The resource management uses of timber, wildlife/fisheries, vegetation protection and watershed improvements are allowed uses in any of the MAP zones as long as such practices are consistent with the Meyers Area Plan.

B. TRPA Code of Ordinances, Chapter 21, Section 21.4, List of Primary Uses, is adopted by reference for the uses listed under Table 130.26.050 (Allowed, Conditional Uses, and Prohibited Uses) below in this Chapter.

Exceptions & meaning →

Sec. 130.26.050 - Matrix of Allowed Uses.

Uses are allowed in the following zones subject to the requirements of this Title as designated in Table 130.26.050 (Allowed, Conditional Uses, and Prohibited Uses) below in this Section:

Table 130.26.050—Allowed, Conditional Uses, and Prohibited Uses

Only those uses listed on the following table and otherwise noted in this Section shall be allowed by right or by Conditional Use Permit within the zones specified. The table has the following designations:

"P" Allowed use;
"CUP" Conditional Use Permit required ( Section 130.52.021 );
(—) Use not allowed in zone.
USE MAP-1 (Center) MAP-2 (Ind) MAP-3 (Res/T) MAP-4 (Rec) MAP-5 (River)
Residential Residential Residential Residential Residential Residential
Employee Housing CUP (3) — CUP CUP —
Multiple Family Dwelling P (6) — P — —
Multiple Person Dwelling (i.e., dormitories, etc.) CUP — — — —
Nursing and Personal Care CUP — — — —
Single Family Dwelling P (4)(6) — P — —
Accessory Dwelling Unit P — P — —
Tourist Accommodation Tourist Accommodation Tourist Accommodation Tourist Accommodation Tourist Accommodation Tourist Accommodation
Time-share units — — — — —
Bed and Breakfast Facilities P — P — —
Hotels/Motels CUP — CUP (7) — —
Commercial (Retail) Commercial (Retail) Commercial (Retail) Commercial (Retail) Commercial (Retail) Commercial (Retail)
Auto/Mobile Homes/Vehicle Dealers — CUP — — —
Building Materials/Hardware P P — — —
Eating and Drinking Places P P — — —
Food and Beverage Sales P P — — —
Furniture/Home Furnishings/Equipment P P — — —
General Merchandise Stores P P — — —
Mail Order and Vending P P — — —
Nursery P P — CUP —
Outdoor Retail Sales CUP CUP — — —
Service Stations CUP CUP — — —
Commercial (Entertainment) Commercial (Entertainment) Commercial (Entertainment) Commercial (Entertainment) Commercial (Entertainment) Commercial (Entertainment)
Amusements and Recreation Services P — — CUP —
Privately Owned Assembly and Entertainment CUP — — — —
Outdoor Amusements CUP — — CUP —
Commercial (Services) Commercial (Services) Commercial (Services) Commercial (Services) Commercial (Services) Commercial (Services)
Animal Husbandry Services CUP P — — —
Broadcasting Studios P P — — —
Business Support Services P P — — —
Contract Construction Services CUP P — — —
Financial Services P P — — —
Health Care Services P P — — —
Personal Services P P — — —
Professional Offices P P — — —
Repair Services CUP P — — —
Schools-Business and Vocational CUP — — — —
Sales Lots — CUP — — —
Secondary Storage CUP (1) CUP — — —
Auto Repair and Service CUP P — — —
Laundries and Dry Cleaning CUP CUP — — —
Commercial (Light Industrial) Commercial (Light Industrial) Commercial (Light Industrial) Commercial (Light Industrial) Commercial (Light Industrial) Commercial (Light Industrial)
Food and Kindred Products CUP (6) P — — —
Fuel and Ice Dealers — P — — —
Industrial Services — CUP — — —
Printing and Publishing CUP (6) P — — —
Commercial (Wholesale/Storage) Commercial (Wholesale/Storage) Commercial (Wholesale/Storage) Commercial (Wholesale/Storage) Commercial (Wholesale/Storage) Commercial (Wholesale/Storage)
Recycling and Scrap — CUP — — —
Small Scale Manufacturing CUP (6) CUP — — —
Storage Yards — CUP — — —
Vehicle/Freight Terminals — CUP — — —
Vehicle Storage and Parking CUP (6) P — — —
Warehousing CUP (6) P — — —
Wholesale and Distribution CUP (6) P — — —
Public Services (General) Public Services (General) Public Services (General) Public Services (General) Public Services (General) Public Services (General)
Churches P — CUP — —
Collections Stations CUP (6) P — — —
Child Day Care Facilities and Preschools P CUP CUP CUP —
Government Offices P CUP CUP — —
Hospitals CUP — — — —
Local Assembly and Entertainment P CUP CUP P —
Local Post Office P — — — —
Local Public Health and Safety Facilities P P CUP CUP CUP
Membership Organizations P — — — —
Publicly Owned Assembly and Entertainment CUP — — CUP —
Public Utility Centers CUP (6) CUP — CUP CUP
Regional Public Health and Safety Facilities CUP CUP — — —
Social Service Organizations P CUP CUP — —
Schools (K-12) CUP — — — —
Cultural Facilities P CUP P P —
Schools/Colleges CUP — — — —
Public Service (Linear Facilities) Public Service (Linear Facilities) Public Service (Linear Facilities) Public Service (Linear Facilities) Public Service (Linear Facilities) Public Service (Linear Facilities)
Pipelines and Power Transmission CUP CUP CUP CUP CUP
Transit Stations and Terminals P P CUP CUP CUP
Transportation Routes CUP (5) CUP (5) CUP (5) CUP (5) CUP (5)
Transmission and Receiving Facilities CUP CUP CUP CUP CUP
Recreation Recreation Recreation Recreation Recreation Recreation
Cross Country Ski Courses P P P P P
Day Use Areas P — P P P
Golf Courses — — — CUP —
Group Facilities CUP — CUP P —
Outdoor Recreation Concessions P CUP CUP P —
Participant Sport Facilities CUP CUP — P —
Recreation Centers P — CUP CUP —
Riding and Hiking Trails P P P P P
Rural Sports — CUP CUP P CUP
Snowmobile Courses — — — CUP —
Sport Assembly CUP — — — —
Visitor Information Center P — CUP P —
Developed Campgrounds — — — P CUP
Undeveloped Campgrounds — — — P CUP
Recreational Vehicle Parks — — — CUP —
(1) Applies only to parcels on Santa Fe Road. (2) Maintenance facilities not allowed within any new transit facilities. (3) One employee housing unit allowed without a CUP per commercial building with at least 1000 sq. ft. of CFA. (4) Single family dwellings in Meyers Community Center limited to condominiums or townhouses with at least 3 attached units. (5) Non-motorized public trails are a permitted use. (6) These uses are not allowed within the portion of the ground floor of a structure that faces the primary entry point for projects adjacent to US 50. This restriction may be waived if the Meyers Advisory Council and the Planning Commission find that the use is otherwise consistent with the intent of the Meyers Area Plan. (7) Hotels/motels are only allowed in the Town Center portion of MAP-3.

(Ord. No. 5152, § 4, 11-16-2021)

Exceptions & meaning →

Sec. 130.26.060 - Development Standards.

A. The following provisions shall apply in all MAP zones unless a variance is obtained in compliance with Section 130.52.070 (Variance) in Article 5 (Planning Permit Processing) of this Title, or a modification is approved by the Advisory Committee for the front yard setback as further described herein.

The following table (Table 130.26.060 - Meyers Area Plan Development Standards) sets forth the applicable lot area, lot width and setback requirements for each MAP zone. Land coverage, building height, development density, and sign standards are further regulated under the TRPA Code of Ordinances and Attachment A of the Meyers Area Plan.

Table 130.26.060—Meyers Area Plan Development Standards

MAP-1 (Center) (6) MAP-2 (Ind) MAP-3 (Res/T) MAP-4 (Rec) MAP-5 (River)
Maximum Height and Density for All Uses Maximum Height (Ft.) (8) 42 TRPA Code Chapter 37 42, TRPA Code Sec. 37.4 (9) TRPA Code Sec. 37.4 TRPA Code Sec. 37.4
Maximum Height and Density for All Uses Density, Single Family Residential NA NA 1 primary unit NA NA
Maximum Height and Density for All Uses Accessory Dwelling Unit NA NA (See Section 130.40.300 ) NA NA
Maximum Height and Density for All Uses Density, Multiple Family (4) 20 units/ acre NA 15 units/acre NA NA
Maximum Height and Density for All Uses Density, Multi-person/Nursing & Personal Care 25 persons/ acre NA NA NA NA
Maximum Height and Density for All Uses Density, Bed and Breakfast 10 units/ acre NA 10 units/acre NA NA
Maximum Height and Density for All Uses Density, All Other Tourist Accommodation 30 units/ acre NA 30 units/ acre (7) NA NA
Maximum Height and Density for All Uses Density, Group Facilities 25 persons/ acre NA 25 persons/ acre 25 persons/ acre NA
Maximum Height and Density for All Uses Density, Campgrounds & Recreational Vehicle Parks NA NA NA 8 sites/ acre for camp-grounds, 10 sites/acre for RV Parks 8 sites/acre for camp grounds
Setbacks and Lot Sizes for All Non-residential Uses Minimum Lot Size (Sq. Ft.) 5,000 10,000 5,000 NA NA
Setbacks and Lot Sizes for All Non-residential Uses Minimum Lot Frontage (Ft.) 50 100 50 NA NA
Setbacks and Lot Sizes for All Non-residential Uses Front Setback (Ft.) 20 (3) 20 (1) 20 (1) 20 (1) 20
Setbacks and Lot Sizes for All Non-residential Uses Side Setback (Ft.) 0 0 0 0 0
Setbacks and Lot Sizes for All Non-residential Uses Rear (Ft.) 0 10 0 0 0
Setbacks and Lot Sizes for All Non-residential Uses Setback Adjacent to Residential (Ft.) 25 25 25 25 0
Setbacks and Lot Sizes for All Non-residential Uses Minimum Lot Size (Sq. Ft.) 6,000 NA 6,000 NA NA
Setbacks and Lot Sizes for All Non-residential Uses Minimum Lot Frontage (Ft.) 60 NA 60 NA NA
Setbacks and Lot Sizes for All Non-residential Uses Front Setback (Ft.) 20 (3) NA 20 (2) NA NA
Setbacks and Lot Sizes for All Non-residential Uses Side Setback (Ft.) 5 NA 5 NA NA
Setbacks and Lot Sizes for All Non-residential Uses Rear Setback (Ft.) 15 NA 15 NA NA
Maximum Transferred Land Coverage (see TRPA Code Sec. 30.4 for additional detail) Maximum Transferred Land Coverage (see TRPA Code Sec. 30.4 for additional detail) 70% of high capability land See TRPA Code Ch. 30 70% of high capability in Town Center overlay; see TRPA Code Ch. 30 for outside of Town Center (5) 70% of high capability in Town Center overlay; see TRPA Code Ch. 30 for outside of Town Center See TRPA Code Ch. 30
(1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the center
line of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the next lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (1) The front setback may be reduced as part of the design review when such reduction supports the policies of the Meyers Area Plan and does not reduce the numerical scenic rating of the roadway unit. (2) Second story cantilever living space not more than 4 feet into front yard. (3) For parcels adjacent to the US 50 ROW in MAP-1 the minimum front setback can be reduced to 1 ft. from property line if the resulting setback is a minimum of 70 ft. from the centerline of US 50 and 35 feet from the centerline of the Pat Lowe multi-use trail. (4) Multiple family density applies to apartments, condominiums, and townhomes. (5) Detached single family dwellings limited to no more than 30% coverage per TRPA Code Sec. 30.4. (6) The maximum density for parcels in the Meyers Community Center Zoning District proposed for a mixture of land uses shall be calculated as a proportional share of the maximum densities used for different project land uses. These densities shall be combined together and rounded to the n
MAP-1 (Center) (6) MAP-2 (Ind) MAP-3 (Res/T) MAP-4 (Rec) MAP-5 (River)
ext lowest whole number. For example, if a 3 acre parcel proposes that 2 acres be used primarily for multiple family (20 units/acre) and 1 acre be used primarily for tourist accommodation other than bed and breakfast (30 units/acre), then the maximum density allowed for the project would be 30 tourist accommodation units and 40 multiple family units. (7) Hotels/motels are only allowed in the Town Center portion of the MAP-3 Zoning District. (8) For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply. (9) A maximum building height of 42 feet is only allowed in the Town Center portion of the MAP-3 Zoning District. For building height above the maximum height of 26 feet, the findings in TRPA Code Sec. 37.7 shall apply.

B. Any new development, additions to existing development, change in use, or exterior modifications to existing development shall be reviewed for consistency with the Meyers Design Standards and Guidelines, and subject to a Design Review Permit in compliance with Section 130.52.030 (Design Review Permit) in Article 5 (Planning Permit Processing) of this Title.

(Ord. No. 5152, §§ 5, 6, 11-16-2021)

Exceptions & meaning →

Explained in plain English

El Dorado County guides that cite this page.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — El Dorado County Municipal Code

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.