Chico Municipal Code Ch. 19.90 Standards for Streets, Alleys and Other Public Ways

Chico Municipal Code · 2026-10 edition · updated 2026-10-04 · Chico

Cite as: Chico Municipal Code Chapter 19.90 · Text as of 2026-10-04

19.90.010 Purpose.

This Chapter provides standards for the design of public streets and the character of the streetscape between buildings across public streets within the TND zoning district.

(Ord. 2358 §22)

Exceptions & meaning →

19.90.020 Applicability.

Except as provided in section 19.90.040, only the street types and standards referenced in this chapter shall be used in a traditional neighborhood development approved in compliance with this Division.

(Ord. 2358 §22)

Exceptions & meaning →

19.90.030 Establishment of an emergency response network and thoroughfare standards.

To ensure adequate emergency response, an Emergency Response Network (ERN) must be established as set forth in this section. The ERN is comprised of primary and secondary streets.

A. Primary Street. A free movement street type with no unwarranted stop signs or signals and no vertical traffic calming measures.

B. Secondary Street. A free movement street type with no unwarranted stop signs or signals. Vertical traffic calming measures are limited to raised intersections and curb extensions (bulbing).

C. ERN streets shall be connected. No cul-de-sacs or dead-end streets are permitted.

D. The maximum distance between ERN intersections shall be 660 feet.

E. Off-Network thoroughfares may be added to the street network providing emergency response. These off-network streets provide additional circulation for vehicles, bicycles, and pedestrians as well as additional public parking.

  1. Buildings addressing onto an off-network thoroughfare where the building is not within 150 feet of an ERN street shall be protected with a fire sprinkler system.

  2. Alleys are considered off-network streets as they are not typically used for emergency response.

F. Table 6-38 below sets forth emergency response network standards.

(Ord. 2358 §22)

Table 6-38 Emergency Response Network Standards

Note: To view Table 6-38 in PDF, please click TABLE 6-38

Chico Municipal Code Title 18R TND Standard # Thoroughfare Type Private Lot Frontage on Thoroughfare Segment Maximum Distance to Primary or Secondary ERN Maximum Block Length Intersection Detailed for Fire Department Vehicle Length of Curb Bulb Out in Parking Lane at Intersections
Primary Emergency Response Network TN-2 Blvd with side drive and bike lane Free Movement Alley Required n/a 660' Yes 20'
Primary Emergency Response Network TN-3 Blvd with bike lanes Free Movement Alley Required n/a 660' Yes 20'
Primary Emergency Response Network TN-4 36' Commercial Street Free Movement Alley Required n/a 660' Yes 20'
Secondary Emergency Response Network TN-5 32' Interior Street Free Movement Alley Required n/a 660' Yes Curb bulb at top of tee intersection 30'
Secondary Emergency Response Network TN-6 27' Interior Street Free Movement Alley Required n/a 660' Yes Curb bulb at top of tee intersection 30'
Secondary Emergency Response Network TN-7 27' Drive at Greenway Free Movement Alley Required n/a 660' Yes Curb bulb at top of tee intersection 30'
Off-Network Thoroughfare TN-8 26' Interior Street One Way Alley Required. Buildings addressing off-network streets farther than 150' from the ERN require NFPA 13 BR fire sprinklers. 500' 400' Yes Curb bulb at top of tee intersection 30'
Off-Network Thoroughfare TN-9 19' Interior Street One Way Alley Required. Buildings addressing off-network streets farther than 150' from the ERN require NFPA 13 BR fire sprinklers. 500' 300' Yes Curb bulb at top of tee intersection 30'
Off-Network Thoroughfare TN-10 19' One-Way Interior Street Free Movement at Green or Square Alley Required. Building addressing off-network streets farther than 150' from the ERN require NFPA 13 BR fire sprinklers. 500' 300' Yes Curb bulb at top of tee intersection 30'
Off-Network Thoroughfare TN-12 20' ROWAlley Accessory unit allowed if fire hose is provided through front of lot. If access is only from the alley and the building is further than 150' from nearest ERN street, NFPA 13 fire sprinklers required in accessory unit. n/a n/a No n/a
Off-Network Thoroughfare TN-14 Mid-Block Passage Buildings greater than 150' from curb of the nearest ERN street require NFPA 13 fire sprinklers. n/a n/a No n/a
Off-Network Thoroughfare n/a Bungalow Court Buildings greater than 150' from curb of the nearest ERN street require NFPA 13 fire sprinklers. n/a n/a No n/a
Off-Network Thoroughfare n/a Walkway for an Engaged Green or Plaza Buildings greater than 150' from curb of the nearest ERN street require NFPA 13 fire sprinklers. n/a n/a No n/a
Exceptions & meaning →

19.90.040 Street and Streetscape Standards.

Each street and streetscape within the TND zoning district shall be designed and constructed in compliance with the street standards set forth in Title 18R which are specifically applicable to the TND zoning district, in addition to the City’s standards for street construction. These standards may be modified by the planning commission where necessary to accommodate existing conditions in a developed area of the City when new street and streetscape improvements are required or constructed.

(Ord. 2358 §22)

Exceptions & meaning →